3.7. Electrical connections
WARNING
: All tasks must be performed in accordance with the safety warnings (see Chapter 1). In
particular, electrical power must be cut before performing the tasks described below.
Note
: Connections must be done
in accordance with the wiring diagrams
included inside the equipment,
as these represent the primary reference instructions
.
3.7.1. Connections required when the booth is delivered unassembled
Safety photocells (see item 68 in section 2.1)
Connect both parts of the 4 connectors (50).
Hold the cables in place with a collar so door movement is not hindered.
Emergency stop
Connect the emergency stop button (see item 63
in section 2.1) of the inside column to the
connector (MM01) located inside the canopy.
Follow the wire color coding.
Canopy components
Connect both parts of the connector (MM02) to link
the canopy components (lights, optional detectors,
etc.) to the electronic board.
MM02
MM01
Collar
50
50
50
50