Adjustment procedure:
1.
Activate the manual door opening and closing function via buttons 1 and 2 of the control
console (see section 4.8.2):
Turn the SYSTEM key switch to the PROGRAM position
Select the current operating mode
7, 8 or 9
Access the FUNCTIONS menu
5
Access the MODE menu
2
Select
OPERATOR
2
Exit the program mode
SYSTEM key switch in the ON position.
2.
Connect the bar display (included) to connector J1.
3.
When the booth is empty, set TR11 so that there are 3 low intensity bars on the display.
4.
Completely turn TR10 clockwise.
5.
Ask someone with a relatively strong or heavy build to enter the booth and let the door close.
6.
Use the same setting—1 or 2 high intensity bars on the display—for components TR1 to TR8
(same angular position).
- Turn clockwise to increase the number of bars.
- Turn counterclockwise to decrease the number of bars.
7.
Ask the person to exit the booth.
8.
Press
PL1.
9.
Ask someone to enter the booth and let the door
close. Turn TR10 counterclockwise so that no
bars are shown on the display.
Ask 2 persons to enter the booth and let
the door close. Turn TR10 until at least 2
bars are shown on the display.
10.
Press
PL1.
11.
Disconnect the bar display.
Note
: Verifications and adjustments must be done while the doors are closed.
TR potentiometers must only be slightly turned.
TR1 to TR8
TR10
TR11
J1
Bar
display
PL1