autogaz AC STAG-100 Скачать руководство пользователя страница 3

 

Page 3 of 17 

WIRING DIAGRAM AND INSTALLATION MANUAL 

The STAG-50/100/150 controller should be mounted within the engine room in the place, which is not 

exposed to high temperature, water and fuel. 

CAUTION! 

 

It is recommended to install the controller vertically using its mounting eye and a screw, placing 

sockets downward to avoid water penetration. Install bundle protecting rubbers carefully to seal the 

entire housing. 

Electrical connections should be soldered, carefully insulated and protected from humidity to avoid 

shorting. 

 

CONTROL PANEL FIXING & INSTALLATION 

The control panel should be mounted within the driver's cab in the range of driver's sight.  

First check fitting of the lower panel part, then drill two openings Ø 1,8 mm for fastening the panel and 

one Ø 5 mm for the bundle. Fix the lower part of the panel (together with a plate) with screws 

(installation set) in the chosen place and cover it with panel's upper part. Check the working mode 

switch function. 

 

50  100  150  CABLE COLOUR 

DESCRIPTION 

11  15  11 

BLACK 

GND 

BLACK-RED 

+12 V BATTERY 

15  13  15 

RED 

+12 V IGNITION SWITCH 

19  14  19 

BROWN 

RPM - 5/12 V PULSES 

14 

14 

BLUE 

LPG SWITCH ON 

12 

12 

YELLOW-GREEN 

TPS 

18  10  18 

WHITE 

LPG LEVEL SEN SOR 

20 

20 

ORANGE 

TEMPERATURE SENSOR 

 

 

 

 

 

16 

YELLOW 

EMULATOR RELAY     ( SWITCHING OVER ) 

17 

WHITE-GREEN 

EMULATOR RELAY     ( CLOSED ) 

18 

GREEN 

EMULATOR RELAY     ( OPEN ) 

 

 

 

 

 

10  15  10 

BLACK 

SWITCHBOARD  LED-100  or  LED-50 ( new )

 * 

(GND) 

WHITE-RED 

SWITCHBOARD  LED-100  or  LED-50 ( new ) 

WHITE-GREEN 

SWITCHBOARD  LED-100  or  LED-50 ( new ) 

GREY-BLACK 

SWITCHBOARD  LED-100  or  LED-50 ( new ) 

3  14

GREEN-RED 

SWITCHBOARD  LED-100                                  (+12V) 

 

 

 

 

 

10 

BLACK 

SWITCHBOARD  LED-50 ( old )                           (GND)           

GREEN-RED 

SWITCHBOARD  LED-50 ( old ) 

YELLOW 

SWITCHBOARD  LED-50 ( old ) 

BROWN 

SWITCHBOARD  LED-50 ( old ) 

 

 

 

 

 

12 

PURPLE 

LAMBDA SENSOR 

13  11  13 

GREY 

CAR COMPUTER ( SIMULATION ) 

 

 

 

 

 

option – WHITE-BLACK 

RESERVED CONNECTION 

23 

 

option – BLUE-BLACK 

RESERVED CONNECTION 

 

 

 

 

19 

BLUE-BLACK 

ACTUATOR 

20 

WHITE-BLACK 

ACTUATOR 

17  21  17 

ORANGE-BLACK 

ACTUATOR 

16  22  16 

VIOLET-BLACK 

ACTUATOR 

*

 STAG-50 only LED-50  ,  STAG-100 only LED-100  ,  STAG-150 - LED-50 or LED-100 

Содержание STAG-100

Страница 1: ...150 LAMBDA SENSOR CONTROLLER INSTALLATION PROGRAMMING MANUAL version V1 77 V1 79 Manufacturer AC Sp ka Akcyjna 15 181 Bia ystok ul 42 Pu ku Piechoty 50 Poland tel 48 85 7438148 fax 48 85 653 8649 www...

Страница 2: ...pply is switched on green LED shines constantly The LPG output is controlled with a actuator and depends on lambda sensor indications All STAG 50 100 150 parameters are set with an external tester or...

Страница 3: ...he working mode switch function 50 100 150 CABLE COLOUR DESCRIPTION 11 15 11 BLACK GND 1 2 1 BLACK RED 12 V BATTERY 15 13 15 RED 12 V IGNITION SWITCH 19 14 19 BROWN RPM 5 12 V PULSES 14 1 14 BLUE LPG...

Страница 4: ...Page 4 of 17 STAG 50 installation diagram...

Страница 5: ...ector power supply point 20 Emulation of injections Emulation of multi point injector yellow white green 12 power supply of all injectors 100 Emulation of injections Fuel pump cutoff yellow white gree...

Страница 6: ...R SUPPLY 9 YELLOW BLACK INJECTOR 1 COMPUTER 3 GREEN INJECTOR 2 POWER SUPPLY 10 GREEN BLACK INJECTOR 2 COMPUTER 4 RED INJECTOR 3 POWER SUPPLY 11 RED BLACK INJECTOR 3 COMPUTER 5 BLUE INJECTOR 4 POWER SU...

Страница 7: ...appears the screen PARAMETERS and transmission percentage indicator If after a few trials the software cannot establish communication with the controller then instead of the transmission percentage i...

Страница 8: ...auges window controller parameters readout grid on start stop oscilloscope oscilloscope time base change save visualisation file open visualisation file oscilloscope on off graph colour change save co...

Страница 9: ...utton or by double clicking relevant line in the signal table It is possible separately for each such window to change its position using left mouse button size buttons shape O button and close X butt...

Страница 10: ...f actuator steps proportional to accelerator s pressing WEAKENING number of actuator steps proportional to accelerator s loosing ACTUATOR SPEED actuator speed during enrichment weakening OPEN addition...

Страница 11: ...mulation pulse upper course TIME LO duration of simulation pulse lower course TIME OFF total time of pauses between pulses groups 0 no pause PULSE NUMBER number of pulses within a group 0 no groups DI...

Страница 12: ...er switching on the ignition switch while working with gasoline LPG LEVEL SENSOR depending on LPG level sensor voltage thresholds for activation of relevant LEDs indicating LPG level FAULTS DETECTED B...

Страница 13: ...be added for individual rpms CONFIGURATION GASOLINE Start controller configuration for gasoline with the key GASOLINE According to dialog window commands proceed as follows start the engine set workin...

Страница 14: ...e use of CONFIGURATION LPG function Adjustment should be done using menu PARAMETERS start the engine in gasoline mode and wait for proper lambda sensor operation set the controller for GASOLINE mode C...

Страница 15: ...software modification After connecting the controller to a PC the new window VERSION appears If the folder containing the program AcLpgWin exe includes also a batch program of the STAG 50 100 150 cont...

Страница 16: ...d successfully appears press OK The controller performs restart and begins to work with the new version of the software If the programming process is interrupted or there are some errors diagnostic so...

Страница 17: ...e disconnected frame Type of changeover gasoline LPG rpm up rpm down rpm TPS Time of simultaneous operation gasoline LPG 0 1 020 s Temperature of switchover gasoline LPG 60 185 C Switchover rpm 1000 1...