autogaz AC STAG-100 Скачать руководство пользователя страница 10

 

Page 10 of 17 

 

STAG-50/100/150 ADJUSTMENT PARAMETERS 

 

    IGNITION COIL 

- according to the connection of rpm pulse and ignition type it is indispensable to 

choose such type of coil to obtain the same rpm  indication at the tachometer and 

software window. In certain vehicles it is indispensable to use an ignition pulse adder. 

 

COIL SIGNAL 

– change of the rpm detection voltage threshold. Set suitable detection level 

depending on rpm pulses voltage value. 

 

    TPS 

- after connection of a throttle opening sensor choose its type and voltage range. 

 

TPS THRESHOLD 

– voltage level, which causes switching over from idle operation to operation 

with load 

 

ADJUSTMENT FROM TPS 

- adjustment from TPS on / off 

 

TPS HISTERESIS 

- removal of voltage noise from the TPS sensor 

 

ENRICHMENT 

- number of actuator steps proportional to accelerator's pressing 

 

WEAKENING 

- number of actuator steps proportional to accelerator's loosing 

 

ACTUATOR SPEED 

- actuator speed during enrichment / weakening 

 

OPEN 

- additional opening of actuator after reaching of TPS level 

 

TPS LEVEL 

- TPS voltage level causing mixture enrichment – additional opening of the  actuator 

 

ACTUATOR AT THE POSITION 

- number of actuator steps during additional opening 

 

ACTUATOR SPEED 

- actuator speed during opening 

 

CUT OFF 

- additional closing of actuator during accelerator's loosing and reaching TPS level 

downward. This function works if rpm falls to the set level. 

 

RPM LEVEL 

- rpm level activating CUT OFF function 

 

ACTUATOR AT THE POSITION 

- number of actuator's steps during CUT OFF execution 

 

ACTUATOR SPEED 

- actuator speed during CUT OFF 

 

    LAMBDA SENSOR TYPE 

- lambda sensor operation range 

 

LAMBDA SENSOR 

- lambda sensor type:  

STANDARD – zirconium 

RESISTIVE (-) – load from the frame 

RESISTIVE (+) – load from the positive pole (+) 

Содержание STAG-100

Страница 1: ...150 LAMBDA SENSOR CONTROLLER INSTALLATION PROGRAMMING MANUAL version V1 77 V1 79 Manufacturer AC Sp ka Akcyjna 15 181 Bia ystok ul 42 Pu ku Piechoty 50 Poland tel 48 85 7438148 fax 48 85 653 8649 www...

Страница 2: ...pply is switched on green LED shines constantly The LPG output is controlled with a actuator and depends on lambda sensor indications All STAG 50 100 150 parameters are set with an external tester or...

Страница 3: ...he working mode switch function 50 100 150 CABLE COLOUR DESCRIPTION 11 15 11 BLACK GND 1 2 1 BLACK RED 12 V BATTERY 15 13 15 RED 12 V IGNITION SWITCH 19 14 19 BROWN RPM 5 12 V PULSES 14 1 14 BLUE LPG...

Страница 4: ...Page 4 of 17 STAG 50 installation diagram...

Страница 5: ...ector power supply point 20 Emulation of injections Emulation of multi point injector yellow white green 12 power supply of all injectors 100 Emulation of injections Fuel pump cutoff yellow white gree...

Страница 6: ...R SUPPLY 9 YELLOW BLACK INJECTOR 1 COMPUTER 3 GREEN INJECTOR 2 POWER SUPPLY 10 GREEN BLACK INJECTOR 2 COMPUTER 4 RED INJECTOR 3 POWER SUPPLY 11 RED BLACK INJECTOR 3 COMPUTER 5 BLUE INJECTOR 4 POWER SU...

Страница 7: ...appears the screen PARAMETERS and transmission percentage indicator If after a few trials the software cannot establish communication with the controller then instead of the transmission percentage i...

Страница 8: ...auges window controller parameters readout grid on start stop oscilloscope oscilloscope time base change save visualisation file open visualisation file oscilloscope on off graph colour change save co...

Страница 9: ...utton or by double clicking relevant line in the signal table It is possible separately for each such window to change its position using left mouse button size buttons shape O button and close X butt...

Страница 10: ...f actuator steps proportional to accelerator s pressing WEAKENING number of actuator steps proportional to accelerator s loosing ACTUATOR SPEED actuator speed during enrichment weakening OPEN addition...

Страница 11: ...mulation pulse upper course TIME LO duration of simulation pulse lower course TIME OFF total time of pauses between pulses groups 0 no pause PULSE NUMBER number of pulses within a group 0 no groups DI...

Страница 12: ...er switching on the ignition switch while working with gasoline LPG LEVEL SENSOR depending on LPG level sensor voltage thresholds for activation of relevant LEDs indicating LPG level FAULTS DETECTED B...

Страница 13: ...be added for individual rpms CONFIGURATION GASOLINE Start controller configuration for gasoline with the key GASOLINE According to dialog window commands proceed as follows start the engine set workin...

Страница 14: ...e use of CONFIGURATION LPG function Adjustment should be done using menu PARAMETERS start the engine in gasoline mode and wait for proper lambda sensor operation set the controller for GASOLINE mode C...

Страница 15: ...software modification After connecting the controller to a PC the new window VERSION appears If the folder containing the program AcLpgWin exe includes also a batch program of the STAG 50 100 150 cont...

Страница 16: ...d successfully appears press OK The controller performs restart and begins to work with the new version of the software If the programming process is interrupted or there are some errors diagnostic so...

Страница 17: ...e disconnected frame Type of changeover gasoline LPG rpm up rpm down rpm TPS Time of simultaneous operation gasoline LPG 0 1 020 s Temperature of switchover gasoline LPG 60 185 C Switchover rpm 1000 1...

Отзывы: