autogaz AC STAG-100 Скачать руководство пользователя страница 14

 

Page 14 of 17 

 

Finish the gasoline configuration pressing one of following keys: 

NEXT 

- LPG mode configuration 

OK 

- save gasoline mode settings 

SKIP 

- skip settings 

 

 

CONFIGURATION – LPG 

 

NOTE: LPG MODE CONFIGURATION SHOULD BE MADE AFTER PRELIMINARY PRESSURE REGULATOR 

ADJUSTMENT! (SEE QUICK START P. 12) 

 

LPG mode configuration may be activated with 

LPG 

or 

NEXT 

- if gasoline configuration has been 

performed previously. 

According to dialog window commands proceed as follows: 

 

set 

AUTO 

working mode (control panel key or mouse) 

 

increase rpm to ca. 2000 to switch over to LPG 

 

leave idle rpm - actuator position will be adjusted 

 

increase to 3000 rpm - actuator position will be adjusted 

 

 

Finish the configuration with: 

OK 

- save LPG mode settings 

SKIP 

- skip settings 

 

Other controller settings as e.g. sensor simulation, LPG mode on level etc. may be adjusted with menu 

PARAMETERS

 

QUICK START, FIRST PRESSURE REGULATOR ADJUSTMENT 

First pressure regulator adjustment must be done before use of 

CONFIGURATION -LPG 

function. 

Adjustment should be done using menu 

PARAMETERS

 

start the engine in gasoline mode and wait for proper lambda sensor operation 

 

set the controller for 

GASOLINE 

mode.  

 

Check lambda sensor operation for idle and 3000 rpm (sensor indications should be between 

upper and lower voltage value). 

 

Set the controller for 

AUTO 

 

Increase rpm to ca. 2000 to switch over to LPG 

 

Watching lambda sensor graph at the oscilloscope adjust LPG output (with an adjustment screw 

located on the pressure regulator) so that the actuator works in the range 50 - 100 steps (idle 

engine rpm) 

 

Check sensor balancing at 3000 rpm 

 

If the sensor shows long return time to balancing during rpm change check pressure regulator 

membrane tension and adjust it with a screw, if necessary. 

 

NOTE: if during pressure regulator adjustment it is impossible to obtain sensor 
balance at high rpm and the mixture is weak, it means that the system pressure 

regulator - mixer does not work properly, thus before adjustment of electronics some 

mechanical components must be adjusted. If the pressure regulator has been 

adjusted and works properly, proceed with 

LPG CONFIGURATION

 

Содержание STAG-100

Страница 1: ...150 LAMBDA SENSOR CONTROLLER INSTALLATION PROGRAMMING MANUAL version V1 77 V1 79 Manufacturer AC Sp ka Akcyjna 15 181 Bia ystok ul 42 Pu ku Piechoty 50 Poland tel 48 85 7438148 fax 48 85 653 8649 www...

Страница 2: ...pply is switched on green LED shines constantly The LPG output is controlled with a actuator and depends on lambda sensor indications All STAG 50 100 150 parameters are set with an external tester or...

Страница 3: ...he working mode switch function 50 100 150 CABLE COLOUR DESCRIPTION 11 15 11 BLACK GND 1 2 1 BLACK RED 12 V BATTERY 15 13 15 RED 12 V IGNITION SWITCH 19 14 19 BROWN RPM 5 12 V PULSES 14 1 14 BLUE LPG...

Страница 4: ...Page 4 of 17 STAG 50 installation diagram...

Страница 5: ...ector power supply point 20 Emulation of injections Emulation of multi point injector yellow white green 12 power supply of all injectors 100 Emulation of injections Fuel pump cutoff yellow white gree...

Страница 6: ...R SUPPLY 9 YELLOW BLACK INJECTOR 1 COMPUTER 3 GREEN INJECTOR 2 POWER SUPPLY 10 GREEN BLACK INJECTOR 2 COMPUTER 4 RED INJECTOR 3 POWER SUPPLY 11 RED BLACK INJECTOR 3 COMPUTER 5 BLUE INJECTOR 4 POWER SU...

Страница 7: ...appears the screen PARAMETERS and transmission percentage indicator If after a few trials the software cannot establish communication with the controller then instead of the transmission percentage i...

Страница 8: ...auges window controller parameters readout grid on start stop oscilloscope oscilloscope time base change save visualisation file open visualisation file oscilloscope on off graph colour change save co...

Страница 9: ...utton or by double clicking relevant line in the signal table It is possible separately for each such window to change its position using left mouse button size buttons shape O button and close X butt...

Страница 10: ...f actuator steps proportional to accelerator s pressing WEAKENING number of actuator steps proportional to accelerator s loosing ACTUATOR SPEED actuator speed during enrichment weakening OPEN addition...

Страница 11: ...mulation pulse upper course TIME LO duration of simulation pulse lower course TIME OFF total time of pauses between pulses groups 0 no pause PULSE NUMBER number of pulses within a group 0 no groups DI...

Страница 12: ...er switching on the ignition switch while working with gasoline LPG LEVEL SENSOR depending on LPG level sensor voltage thresholds for activation of relevant LEDs indicating LPG level FAULTS DETECTED B...

Страница 13: ...be added for individual rpms CONFIGURATION GASOLINE Start controller configuration for gasoline with the key GASOLINE According to dialog window commands proceed as follows start the engine set workin...

Страница 14: ...e use of CONFIGURATION LPG function Adjustment should be done using menu PARAMETERS start the engine in gasoline mode and wait for proper lambda sensor operation set the controller for GASOLINE mode C...

Страница 15: ...software modification After connecting the controller to a PC the new window VERSION appears If the folder containing the program AcLpgWin exe includes also a batch program of the STAG 50 100 150 cont...

Страница 16: ...d successfully appears press OK The controller performs restart and begins to work with the new version of the software If the programming process is interrupted or there are some errors diagnostic so...

Страница 17: ...e disconnected frame Type of changeover gasoline LPG rpm up rpm down rpm TPS Time of simultaneous operation gasoline LPG 0 1 020 s Temperature of switchover gasoline LPG 60 185 C Switchover rpm 1000 1...

Отзывы: