background image

 

7

 

 

The

 

GENESIS

 

board

 

is

 

one

 

of

 

the

 

most

 

advanced

 

boards

 

on

 

the

 

market

 

to

 

meet

 

all

 

the

 

requirements

 

for

 

en-

trapment

 

for

 

UL-325.

  

Your

 

gate

 

will

 

not

 

operate

 

without

 

wiring

 

in

 

the

 

necessary

 

“reversing

 

protec on”

 

equipment.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The

 

board

 

has

 

been

 

designed

 

to

 

meet

 

just

 

about

 

any

 

accessory

 

device

 

and

 

applica on

 

you

 

can

 

think

 

of.

  

Please

 

review

 

the

 

next

 

few

 

pages

 

for

 

details

 

on

 

each

 

board

 

INPUT,

 

OUTPUT,

 

POWER

 

and

 

FUSING

 

details.

  

 



Standard INPUTS for OPEN, CLOSE, STOP, Loops, Access Controls, Pushbuttons, etc. 



6 “MONITORED” 10K entrapment device INPUTS for OPEN and CLOSE obstruction 



 

Dedicated 1 BEAM and 1 EDGE “OPEN” obstruction 



 

Dedicated 1 BEAM and 1 EDGE “CLOSE” obstruction 



 

Two additional programmable for either OPEN or CLOSE obstruction 



Additional Programmable Relays 



Additional Programmable INPUTS 



Additional Programmable OUTPUTS 



24VDC Fused Accessory Power 

12VDC Fused Accessory Power 
 
 

SPECIAL

 

NOTE:

 

The

 

GENESIS

 

board

 

can

 

be

 

retro

 

fi

t

 

into

 

older

 

operators.

  

If

 

a

 

Genesis

 

board

 

is

 

to

 

be

 

used

 

in

 

non-

monitored

 

entrapment

 

device

 

gate

 

system,

 

the

 

required

 

OPEN

 

&

 

CLOSE

 

monitored

 

inputs

 

can

 

be

 

deac vated.

  

This

 

will

 

require

 

a

 

special

 

passcode

 

to

 

allow

 

the

 

servicing

 

dealer

 

24-hour

 

access

 

to

 

programming

 

that

 

can

 

bypass

 

the

 

UL

 

Rev.

 

6

 

code.

  

To

 

get

 

the

 

pass

 

code,

 

a

 

phone

 

call

 

to

 

AutoGate

 

with

 

the

 

gate

 

serial

 

number

 

or

 

AG

 

#

 

and

 

the

 

8

-character

 

code

 

displayed

 

on

 

the

 

access

 

screen.

  

The

 

AutoGate

 

representa ve

 

will

 

read

 

back

 

a

 

5-character

 

code

 

that

 

will

 

need

 

to

 

be

 

entered

 

on

 

the

 

display.

  

Again,

 

this

 

will

 

allow

 

24-hour

 

access

 

to

 

this

 

special

 

programming

 

func on.

   

A er

 

that,

 

if

 

there

 

would

 

ever

 

be

 

a

 

reason

 

to

 

access

 

the

 

special

 

programming

 

func ons,

 

a

 

new

 

passcode

 

would

 

be

 

needed.

 

 
 
See the following pages for definitions of each terminal on the GENESIS control board. 

Genesis Controller (cont.)

 

P4 & P5

 

MONITORED DEVICE CONNECTIONS POINTS 

 GENESIS INPUT & OUTPUT DETAILS

 

Содержание VPG2490

Страница 1: ...1 2490 GENESIS Introduction MODEL VPG2490 FULL SIZE MANUAL AVAIALBLE TO DOWNLOAD AND PRINT AT WWW AUTOGATE COM...

Страница 2: ...figura on The new configura on will provide be er control of the gate mo on and will prevent the gate from OVERRUNNING the motor There will be 2 drive configura ons used The standard speed will open o...

Страница 3: ...keep the motor moun ng as sembly square either using a tape measure or the notches in the moun ng slides When properly aligned belt tension should be the same in all three belts The GATE drive belt o...

Страница 4: ...of the pow er supply The board will s ll control the gate as normal but the motor will run from the ba ery ba eries The on board charging system will now charge the ba eries from the solar panels when...

Страница 5: ...e input or an over load of the amp draw on the output The power supplies have a built in overload protec on to prevent damage to itself or the control board If the power supply over heats it will shut...

Страница 6: ...it switches P14 Loop Rack Accessory Wiring harness port Used with our LR 3 Loop Rack board J1 USB For data connec on future use P6 Program Plug Used to update board so ware cont P4 P5 Pg 7 8 P1 Pg 6 P...

Страница 7: ...24VDC Fused Accessory Power 12VDC Fused Accessory Power SPECIAL NOTE The GENESIS board can be retro fit into older operators If a Genesis board is to be used in non monitored entrapment device gate s...

Страница 8: ...at full open un l an INTENDED INPUT is ac vated Keypad Reader Push Bu on Free Exit The close command will close the gate and clear the hold command An Open command or a Reverse command not the Close...

Страница 9: ...the open posi on When in constant pressure mode close input responds on ini al press Not com mon on Ver cal Pivot Gate If held in upward mo on no e ect If held in downward mo on gate movement is paus...

Страница 10: ...Ac ve for condi ons related to UL325 specifica ons Lock Programmable Selectable Magne c lock op on Ac ve when the gate is closed Solenoid Interlock op on Momentary ac va on to open the bolt that mech...

Страница 11: ...o move OPEN Pulse on Motor CLOSE 2 second Pulse when gate starts to CLOSE Hold on Motor OPEN Latches Relay on when gate is OPENING Hold on Motor CLOSE Latches Relay ON when gate is CLOSING P12 P13 AUX...

Страница 12: ...e properly set when it leaves the factory If you need to adjust it refer to the instruc ons below If you need to replace contact AutoGate ADJUSTING THE LIMIT POSITION SENSOR 1 In programming mode Set...

Страница 13: ...ear and ghtness See page 44 for instruc ons Every 6 months Charge voltage for ba eries should be 27 5 VDC with ba eries disconnected check at ba ery in maintenance menu Every 6 months Check ba ery wat...

Страница 14: ...on the GATE DRIVE belts 8 by using a 15 16 wrench This too needs to be fully loosened to allow enough room to remove the belts 7 Remove old belts and install new belts loosely 8 Apply snug pressure to...

Страница 15: ...n bolt NOTE Grease fitting must point down Tighten bottom nut NOTE Chain MUST remain level and not twisted once tightened 10 Remove T M pin and restore AC DC power 11 Lowering the gate Initiate the ga...

Страница 16: ...ides top bo om of the Slide Assembly Angle 2 Only adjust the nuts 3 to 4 turns 1 4 at a me and check your amperage readings a er each adjustment NOTE your Amps in the OPEN mode should be approximately...

Отзывы: