background image

INSTRUCTION MANUAL CHARGE COMPLEX «K»

16

The «DC Output» indicator light flashes green 

frequently when the vehicle is being charged in 

Chademo and CCS mode, and the LCD screen displays 

information about the time passed since the charging 

started, the charging current and the voltage.

The modes and text about the operation of the charging system on the LCD display depend 

on the software version and may vary from version to version.

In case of any error in the charging complex, to perform 

diagnostics and restore the operation, please, inform 

the service center about the factory number of the 

charging complex (the number of the charging complex 

is shown in the pic. «M006335»).

While the vehicle charging mode is active, station 

displays information about the charging time, voltage 

level and current value

AutoEnterprise

#1 : Charging

#1 : Charging

#1 : Ready

V:2.02.1642

0:00:50       

0:05:25        

M006335

42.8A/366V

0.4 kWh 

Plug in the connector

The operating modes of the charging complex are displayed on the LCD display, which, 

among other things, displays the following information: operating modes (ready to 

charge, the battery charge of the vehicle), the software and firmware version, the number 

of the complex, the status of the GSM network (signal strength, network status),  vehicle 

authorization process.

Содержание CHARGE COMPLEX K Series

Страница 1: ...CHARGE COMPLEX K Instruction manual...

Страница 2: ...written permission Any violation of the law will be prosecuted Autoenterprise cannot be held liable for any direct or indirect damages resulting from the use or operation of the electrical circuits o...

Страница 3: ...abel 6 3 Application area station specifications 7 3 1 Application area 7 3 2 Complex Specifications 7 3 3 Equipment modifications 9 3 4 General electrical safety information 9 4 Technical specificati...

Страница 4: ...t allow for the exchange of information with the electric vehicle and set the value of the charge current and voltage according to the needs of the electric vehicle in real time 2 KEY INFORMATION 2 1...

Страница 5: ...y subsequent damages or consequential damages Strict adherence to the safety procedures described in these operating instructions and special care when using the equipment are essential to prevent and...

Страница 6: ...onal guidelines for the disposal of electronic and electrical waste 2 5 MANUFACTURER S LABEL The marking on the charging complex is located on the GSM modem inside the complex on the side of the contr...

Страница 7: ...ended use Only charge compatible electric vehicles Failure to follow the instructions for use maintenance and repair described in these operating instructions excludes any liability on the part of the...

Страница 8: ...ptional Stand alone operation Delivery contents Charging station user manual Charging station dimensions 314 1056 2122 mm Type of installation Floor Wall mounting Online device monitoring Yes Current...

Страница 9: ...3 4 GENERAL ELECTRICAL SAFETY INFORMATION Follow the safety instructions to avoid injury and material damage when working with the device Failure to follow these instructions can result in injury and...

Страница 10: ...tation is structurally designed as a monoblock mounted on a pillar and has the following control and management bodies Encased charging station on a pillar 1 pc Connector Type 1 with cable 1 pc Connec...

Страница 11: ...2 Mennekes 1 3 63 43 380 CHAdeMO 1 125 60 480 CCS Type 2 1 125 60 480 CHARGE COMPLEX K 2 Socket type Quantity Current Max power kWh Max voltage V Type 1 SAE J1772 1 80 19 240 Type 2 Mennekes 1 3 63 4...

Страница 12: ...The emergency stop button is located at the bottom of the unit housing When the emergency stop button is pressed in DC charging mode the charging station control circuit is automatically deactivated...

Страница 13: ...t the charging complex with the utmost care Take into account the centre of gravity of the charging system during transportation minimize the risk of tipping over Take measures to prevent the charger...

Страница 14: ...wer cable not included in the delivery set When routing the power cable appropriate insulation must be used It is recommended to lay and connect the power cable inside the charging station s rack befo...

Страница 15: ...it is necessary to connect the power cable to the AC mains and then move the three pole circuit breakers 1 2 3 and 4 to the working position up The operating modes of the charging complex are displaye...

Страница 16: ...the service center about the factory number of the charging complex the number of the charging complex is shown in the pic M006335 While the vehicle charging mode is active station displays informati...

Страница 17: ...ld be dry free of dust caustic materials vapours and combustible materials Storeinastorageroomwithappropriateweatherprotection Do not expose the charger to impacts Storageconditions Storage Temperatur...

Страница 18: ...tem operation and strictly adhere to all safety instructions In the course of operation the following maintenance are carried out Visual inspection for overheating of equipment check pulling connectio...

Страница 19: ...find out the reason for the lack of voltage Circuit breakers or RCD charging system triggered Restore the operation circuit breakers or RCDs of the charging complex Other malfunctions The charging com...

Страница 20: ...supply by means of external disconnection devices IN SEQUENCE 1 Make sure that the input voltage of the charger is disconnected 2 Carry out disassembly work INFORMATION Always use suitable tools to d...