To connect the system to the electrical circuit, open the rear wall of the station (side 2), 

which houses the busbars for connecting the input power cable.

Next, connect the power cable to the appropriate busbars (as shown in the scheme). If the 

connection is made with a 4-wire cable, the external grounding should be done with a 

wire of a cross section of at least 16 mm2 by means of a bolted connection M10 with the 

inscription «PE», located in the terminal compartment. It is strictly forbidden to supply 

voltage to the mains input of the charger when the grounding is not connected.

THE FIRST CONNECTION TO BE MADE IS THE 

GROUND WIRE TO THE GROUND BUSBAR MARKED 

«PE». DO NOT SWITCH ON THE CHARGER WITHOUT 

A CONNECTED GROUNDING!

Non-compliance with this requirement may result in the energizing 

the charger body, electric shock damage to the service personnel and 

consumers, as well as in a failure of the charger.
If the charging complex is not equipped with inverters, it is necessary to 
install and connect the DC modules recommended by the manufacturer 
(video on the order of their connection is sent on request). 

Then, with the help of external switching devices, it is necessary to connect 

the power cable to the AC mains and then move the three-pole circuit 
breakers 1, 2, 3 and 4 to the working position (up):

The operating modes of the charging complex are displayed on the LCD 

display, which, among other things, displays the following information: 
operating modes (ready to charge, the battery charge of the vehicle), the 

software and firmware version, the number of the complex, the status of 

the GSM network (signal strength, network status),  vehicle authorization 
process. 

To switch the charging complex on it is necessary to:

• Install a mobile network operator’s SIM card;
• 

Iurn residual current devices (RCDs) to the working 

position (up);

• Move circuit breakers to working position (up).

4.4    COMPLEX CONNECTION

Ensure that all internal components are properly secured after transportation.
Check the quality of wire, loop, and connector connections. Check the tightening torque of 

terminals, bolts, screws, and switchgear.

The charger does not require any special adjustment or tuning before it is put into operation.

Before you connect the charger, make sure that:

• The power supply cable on the mains side is de-energized by means of external disconnecting 

devices.

• The mains supply is connected as shown in the wiring diagram: 3 phases with separate Neutral 

(N) and grounding (PE) conductors

• When connecting with a 4-wire cable, carry out the protective grounding with a separate 

wire.

Содержание CHARGE COMPLEX K Series

Страница 1: ...CHARGE COMPLEX K Instruction manual...

Страница 2: ...written permission Any violation of the law will be prosecuted Autoenterprise cannot be held liable for any direct or indirect damages resulting from the use or operation of the electrical circuits o...

Страница 3: ...abel 6 3 Application area station specifications 7 3 1 Application area 7 3 2 Complex Specifications 7 3 3 Equipment modifications 9 3 4 General electrical safety information 9 4 Technical specificati...

Страница 4: ...t allow for the exchange of information with the electric vehicle and set the value of the charge current and voltage according to the needs of the electric vehicle in real time 2 KEY INFORMATION 2 1...

Страница 5: ...y subsequent damages or consequential damages Strict adherence to the safety procedures described in these operating instructions and special care when using the equipment are essential to prevent and...

Страница 6: ...onal guidelines for the disposal of electronic and electrical waste 2 5 MANUFACTURER S LABEL The marking on the charging complex is located on the GSM modem inside the complex on the side of the contr...

Страница 7: ...ended use Only charge compatible electric vehicles Failure to follow the instructions for use maintenance and repair described in these operating instructions excludes any liability on the part of the...

Страница 8: ...ptional Stand alone operation Delivery contents Charging station user manual Charging station dimensions 314 1056 2122 mm Type of installation Floor Wall mounting Online device monitoring Yes Current...

Страница 9: ...3 4 GENERAL ELECTRICAL SAFETY INFORMATION Follow the safety instructions to avoid injury and material damage when working with the device Failure to follow these instructions can result in injury and...

Страница 10: ...tation is structurally designed as a monoblock mounted on a pillar and has the following control and management bodies Encased charging station on a pillar 1 pc Connector Type 1 with cable 1 pc Connec...

Страница 11: ...2 Mennekes 1 3 63 43 380 CHAdeMO 1 125 60 480 CCS Type 2 1 125 60 480 CHARGE COMPLEX K 2 Socket type Quantity Current Max power kWh Max voltage V Type 1 SAE J1772 1 80 19 240 Type 2 Mennekes 1 3 63 4...

Страница 12: ...The emergency stop button is located at the bottom of the unit housing When the emergency stop button is pressed in DC charging mode the charging station control circuit is automatically deactivated...

Страница 13: ...t the charging complex with the utmost care Take into account the centre of gravity of the charging system during transportation minimize the risk of tipping over Take measures to prevent the charger...

Страница 14: ...wer cable not included in the delivery set When routing the power cable appropriate insulation must be used It is recommended to lay and connect the power cable inside the charging station s rack befo...

Страница 15: ...it is necessary to connect the power cable to the AC mains and then move the three pole circuit breakers 1 2 3 and 4 to the working position up The operating modes of the charging complex are displaye...

Страница 16: ...the service center about the factory number of the charging complex the number of the charging complex is shown in the pic M006335 While the vehicle charging mode is active station displays informati...

Страница 17: ...ld be dry free of dust caustic materials vapours and combustible materials Storeinastorageroomwithappropriateweatherprotection Do not expose the charger to impacts Storageconditions Storage Temperatur...

Страница 18: ...tem operation and strictly adhere to all safety instructions In the course of operation the following maintenance are carried out Visual inspection for overheating of equipment check pulling connectio...

Страница 19: ...find out the reason for the lack of voltage Circuit breakers or RCD charging system triggered Restore the operation circuit breakers or RCDs of the charging complex Other malfunctions The charging com...

Страница 20: ...supply by means of external disconnection devices IN SEQUENCE 1 Make sure that the input voltage of the charger is disconnected 2 Carry out disassembly work INFORMATION Always use suitable tools to d...

Отзывы: