To connect the system to the electrical circuit, open the rear wall of the station (side 2),
which houses the busbars for connecting the input power cable.
Next, connect the power cable to the appropriate busbars (as shown in the scheme). If the
connection is made with a 4-wire cable, the external grounding should be done with a
wire of a cross section of at least 16 mm2 by means of a bolted connection M10 with the
inscription «PE», located in the terminal compartment. It is strictly forbidden to supply
voltage to the mains input of the charger when the grounding is not connected.
THE FIRST CONNECTION TO BE MADE IS THE
GROUND WIRE TO THE GROUND BUSBAR MARKED
«PE». DO NOT SWITCH ON THE CHARGER WITHOUT
A CONNECTED GROUNDING!
Non-compliance with this requirement may result in the energizing
the charger body, electric shock damage to the service personnel and
consumers, as well as in a failure of the charger.
If the charging complex is not equipped with inverters, it is necessary to
install and connect the DC modules recommended by the manufacturer
(video on the order of their connection is sent on request).
Then, with the help of external switching devices, it is necessary to connect
the power cable to the AC mains and then move the three-pole circuit
breakers 1, 2, 3 and 4 to the working position (up):
The operating modes of the charging complex are displayed on the LCD
display, which, among other things, displays the following information:
operating modes (ready to charge, the battery charge of the vehicle), the
software and firmware version, the number of the complex, the status of
the GSM network (signal strength, network status), vehicle authorization
process.
To switch the charging complex on it is necessary to:
• Install a mobile network operator’s SIM card;
•
Iurn residual current devices (RCDs) to the working
position (up);
• Move circuit breakers to working position (up).
4.4 COMPLEX CONNECTION
Ensure that all internal components are properly secured after transportation.
Check the quality of wire, loop, and connector connections. Check the tightening torque of
terminals, bolts, screws, and switchgear.
The charger does not require any special adjustment or tuning before it is put into operation.
Before you connect the charger, make sure that:
• The power supply cable on the mains side is de-energized by means of external disconnecting
devices.
• The mains supply is connected as shown in the wiring diagram: 3 phases with separate Neutral
(N) and grounding (PE) conductors
• When connecting with a 4-wire cable, carry out the protective grounding with a separate
wire.