6-5
SAFETY & SECURITY
disabled by pressing the test button - if there
is no sound from the sounder then the clip
has been fitted correctly.
Note:
If the disabling tab is no longer
available then the clip can be replicated by
opening out a thin metal paper clip into a U-
shape.
Operating Features
Your FireAngel detector offers many features
which set it apart from other CO detectors on
the market today.
Test/Reset Button Feature
This button will:
•
Test the sounder, power pack and
circuitry.
•
Allows you to test the sensor by
introducing a source of CO into the
detector (see ‘Testing The Sensor’).
•
Silence the loud 8.5dB (at 1 metre (3
feet)) sounder during an alarm (only for
alarms due to levels of CO of less than
50ppm)
Testing the sounder, power pack and circuitry
Test the sounder, power pack and circuitry by
pressing and releasing the Test/Reset button
to confirm that the detector is operating
properly. The sounder should sound as soon
as the button is pressed, and the Alarm LED
will illuminate red indicating that the sounder
is working and the power pack is providing
power to the unit. This test for the sounder,
power pack and circuitry should be
performed on a weekly basis.
Testing the sensor
Note:
We suggest the use of an incense stick
or cigarette as the inefficient way in which
these products burn means the smoke given
off contains a detectable localised amount of
carbon monoxide. Alternative sources of
Fig 2
smoke, for example an extinguished candle
or match, will not contain sufficient levels of
carbon monoxide to obtain a response from
the detector during this test. Please note your
CO detector will not detect smoke.
CAUTION:
Sensor testing should only be
performed by a responsible adult. This test
should be performed annually.
Note:
CO test kits may be used in order to
avoid having to burn cigarettes, incense
sticks etc. However we recommend that
incense sticks are used as they are cheap
and readily available.
Read all steps thoroughly before attempting
to test the sensor.
Step 1 If the detector is wall or ceiling
mounted unhook the detector from
the screws.
Step 2 Cover the sounder vents with one
hand. Press and hold the Test/Reset
button down with your thumb/finger
until the Fault LED illuminates yellow
and the sounder sounds for a second
time (this should happen after around
5 seconds). Release the Test/Reset
button. Upon releasing the Test/
Reset button the Fault LED will flash
yellow once every second. This
indicates that the sampling rate of the
detector has increased and can be
tested using a known source of CO.
Step 3 Light a cigarette or an incense stick
using a match or lighter. If using an
incense stick be sure to blow out the
flame so that the incense stick is
smouldering. Extinguish the lighter,
or put out the match and place it into
a dish of water.
Содержание Symbol Plus 2018
Страница 6: ...1 4 ...
Страница 10: ...2 4 MOTORHOME CODE ...
Страница 16: ...5 2 ARRIVAL AT SITE ...
Страница 58: ...7 34 CONNECTION OF SERVICES 12V WIRING DIAGRAM ...
Страница 59: ...7 35 CONNECTION OF SERVICES 230V WIRING DIAGRAM ...
Страница 60: ...7 36 CONNECTION OF SERVICES ...
Страница 89: ...9 25 FITTED EQUIPMENT 1 2 3 01 03 06 07 08 09 10 11 12 13 14 02 04 4 5 6 7 8 9 10 11 12 13 14 15 ...
Страница 93: ...9 29 FITTED EQUIPMENT CONNECTION OF TV SATELLITE SYSTEM STANDARD ...
Страница 94: ...9 30 FITTED EQUIPMENT CONNECTION OF TV SATELLITE SYSTEM WITH OPTIONAL MEDIA PACK ...
Страница 104: ...9 40 FITTED EQUIPMENT ...
Страница 124: ...12 10 SERVICE DETAILS ...
Страница 126: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 HB1131 MY 2018 Ref 21627 ...