34
FITTED EQUIPMENT
09
RESIDUAL CURRENT DEVICE &
MINIATURE CIRCUIT BREAKERS
The Residual Current Device (RDC) is
basically provided to protect the user
from lethal electric shock. The RCD will
turn off (trip) if the current flowing in
the live conductor does not fully return
down the neutral conductor, i.e. some
current is passing through a person down
to earth or through a faulty appliance.
To ensure the RCD is working
correctly, the test button
should be operated each time
the vehicle is connected to
the mains supply (see section 5.1)
The Miniature Circuit Breakers (MCB’s)
operate in a similar way to traditional
fuses and are provided to protect the
wiring installation from overload or short
circuit. If an overload occurs the MCB will
switch off the supply. If this occurs you should
investigate the cause of the fault before
switching the MCB back on.
SECTION
The following table shows the rating and circuit allocation for the three MCB’s
MCB
Rating
Wire Colour
Description
1
10 Amps
White
230V Sockets
2
10 Amps
White (Yellow for heater)
Extra 230V Sockets / Heater
3
6 Amps
Black
Fridge / 12V Charger
(Internally connected)