11
Australian
Technology
Control Unit
(I) “LIGHT” for a Flash lamp,24VDC.
(2) “MOTOR 1 “, “MOTOR 2” for 2 motors 24VDC.
(3) “LIMIT 1”, “LIMIT 2” for the magnetic limit switch on motor 1, motor 2.
(It is useful only for the motors with magnetic limit switch.)
(4) “PHOTOCELL” for infrared protect device.
(5) “BUTTON”for wall switch. “PUSH 1 “control double-leaf gate, step-by-step “PUSH 2”control single leaf
gate which must be the priority of opening one step-by-step.
(6) “E_ LOCK” for electronic lock, It can be convected with electronic lock which power is 24VDC.
(7)
Connection of motor for single-leaf :
If the gate is only 1 leaf, the motor must be connected with
“Motor1”, and the “dip 2” on “S5” must be OFF.
(8)
Connection of motor for double-leaf :
Ifthe gate is two leaves, first, it must be confirmed which one
leaf is the priority openning one. Then, the priority openning leaf must be connected with
“MOTOR1”
,
the otherone is connected with “MOTOR2”.
And the “dip2” on “S5” must be “ON”.
Wiring Diagram
Содержание Rotary Arm
Страница 8: ...8 Australian Technology How to release Fix the Front Brackt Gate Motor Relese Bending arm...
Страница 12: ...12 Australian Technology OPEN FIRST OPEN FIRST...
Страница 14: ...14 Australian Technology Standard installation layout...
Страница 15: ...15 Australian Technology Installation dimensions Installation...
Страница 16: ...16 Australian Technology...
Страница 17: ...17 Australian Technology...
Страница 19: ...19 Australian Technology Right Open First Left Open First...
Страница 20: ...20 Australian Technology Meaning of display...