background image

2

Australian
Technology

•  Wrong operation may result in injury or even death to the user.

•  Wrong operation may result in injury or physical damage to the operator.

•  This operator needs to be connected with stabilised and uninterrupted power supply for safety 

of micro-controller unit and the operator.

•  Installation  and  adjustment  must  be  carried  out  according  to  the  Installation  Manual. 

Carelessness in installation and adjustment may result in accidents such as fire, electric shocks 
or fall off.

•  During the installation do not allow the pedestrians to pass through the automatic gate or 

approach the work site. Because any tools or parts fall off during the installation may result in 
injury to the pedestrians.

•  Don’t remodel the parts , otherwise fire , electric shocks or fall may occur.

•  Don’t  use  the  power beyond  the  stipulated  voltage  or  frequency, otherwise fire  or electric 

shocks may occur.

•   Do fix up auxiliary safety beam sensor to ensure the detecting range for the walking area of 

the gate leaf, otherwise the passers-by may be collided or squeezed by the gate leaf, causing 
injury.

Thank you for your purchase of our automatic gate equipment.

Your automatic gate operator has been designed and manufactured to comply with stringent 
safety requirements for compliance to the Australian standard.

It is essential that you make yourself familiar with and at least once a week or more regularly check 
the safety features of the gate to ensure safety of the users. If you find that the gate operator is 
unsafe then it must be rendered to a safe condition by either leaving it fully open or fully shut.

Always  engage  Auto  Ingress  authorized  service  technician  for  periodic  inspections  and 
maintenance of this equipment.

We  recommend  services  every  quarter  of  the  year  to  ensure  safety  of  users  and  longevity  of 
operator life cycle.

In accordance with the safety and maintenance requirements of this equipment, Auto Ingress 
has  developed  a  set  of  procedures  to  ensure  optimum  safety  and  long  term  reliability  of  this 
installation.

Safety Precautions

IMPORTANT SAFETY MESSAGE

Содержание Rotary Arm

Страница 1: ...Installation Manual Swing Gate Operator SCISSOR ARM Automatic Entrence Solution Provider ROTARY ARM 24 x 7 Service Support 91 755 00 22 007 91 733 88 52 901 905 DESIGN MANUFACTURE SALES SERVICE...

Страница 2: ...nsure the detecting range for the walking area of the gate leaf otherwise the passers by may be collided or squeezed by the gate leaf causing injury Thank you for your purchase of our automatic gate e...

Страница 3: ...he adhesive sticker on the gate leaf firmly If not it may cause injury to the passer by who didn t pay attention to the gate leaf Don t connect an external electric device to the micro controler as it...

Страница 4: ...Installation Before using the machine check power supply grounding voltage etc Check whether it is connected according to the demand of wiring diagram The gate should be pulled easily and smoothly ma...

Страница 5: ...5 Australian Technology Installation dimensions Standard installation layout Motor Control box Transmitters Photocell Optional Alarm lamp Optional...

Страница 6: ...6 Australian Technology Fix the Motor s Fix the mounting bracket Fix the straight arm Motor Straight arm M10 x 20 10 Gasket Motor M8 x 160 Mounting bracket M8 nut...

Страница 7: ...7 Australian Technology Connect the bending arm Connect the Front Brackt Motor Straight arm M8 nut 8 Gasket Bending arm M8 x 45 Bending arm M8 nut 8 Gasket Front Bracketr Bending arm M8 x 30...

Страница 8: ...8 Australian Technology How to release Fix the Front Brackt Gate Motor Relese Bending arm...

Страница 9: ...as follow The billowing is a Right motor s limit switch adjustment Before adjusting release the gears and open the gate manually For left motor all direction are contrary Step I Close thc door comple...

Страница 10: ...n the door completeIy and confirm which one is the open Limit Block according to the situation then loosen the screw adjustor on Open Limit Block Slep 3 Couple the gears turn on the power adjust more...

Страница 11: ...gate which must be the priority of opening one step by step 6 E_ LOCK for electronic lock It can be convected with electronic lock which power is 24VDC 7 Connection of motor for single leaf If the ga...

Страница 12: ...12 Australian Technology OPEN FIRST OPEN FIRST...

Страница 13: ...ne check power supply grounding voltage etc Check whether it is connected according to the demand of wiring diagram The gate should be pulled easily and smoothly manually when the operator is fitted a...

Страница 14: ...14 Australian Technology Standard installation layout...

Страница 15: ...15 Australian Technology Installation dimensions Installation...

Страница 16: ...16 Australian Technology...

Страница 17: ...17 Australian Technology...

Страница 18: ...ith step by step PUSH 2 controls single leaf gate which must be the priority of opening one with step by step 6 E_ LOCK for electric lock It can be connected with electric lock which power is 24VAC or...

Страница 19: ...19 Australian Technology Right Open First Left Open First...

Страница 20: ...20 Australian Technology Meaning of display...

Страница 21: ...thorised connection to the Micro Controller will make the Warranty invalid 2 If the installation is not carried out as per Auto Ingress recommended guideline Warranty is void 3 For activation of the o...

Отзывы: