37
NexStar Troubleshooting
HC-7X NEXSTAR
NexStar Error Code Table
INFO BOX
CAUSE
EFFECT
SOLUTION
CWW ROT INTO
A8
Crane wint into
overload while rotating
counter-clockwise from
Zone A to Zone B (if
applicable)
Disables counter-
clockwise rotation, boom
down, and hoist up.
Rotate clockwise to return to Zone A or reduce
load to clear alarm.
E002 ACTIVITY
Switch or trigger was
active when linking
transmitter
Disables all functions.
Disengage switch or trigger then push horn
button to relink transmitter.
E004 LOW
BATTERY
Transmitter batteries
are low
Disables all functions
and shuts down
transmitter.
Charge or tether transmitter.
E006 INACTIVITY Transmitter has been
inactive for a set time
and will go to sleep.
All non latching
functions will be
disabled until transmitter
awakens.
Press and release trigger to awaken transmitter.
E007 ESTOP
ACTIVE
E-stop has been
depressed
Disables all functions.
Pull E-stop to release. Turn transmitter off then
back on. Press horn button to relink.