![AUTEC Modular series Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/autec/modular-series/modular-series_user-manual_3020259032.webp)
9 Diagn
ostics
- 28 -
LIMM&SA0-00.fm
9
DIAGNOSTICS
If the system “radio remote control” does not start, check if the problem is caused by
the radio remote control or the machine. Therefore, before carrying out any verification connect
the cable control unit: if the machine does not start, the problem lies with the machine itself.
If, on the other hand, the machine only starts when using the cable control unit, the problem
lies with the radio remote control. In this case, follow the diagnostic procedure related to the
transmitting unit and that related to the receiving unit if it is the case, and proceed as follows.
Before carrying out diagnostics it is recommended to replace the battery with a
charged one and ensure the efficiency of the starting keyswitch.
9.1
Transmitting unit diagnostics
When START is
activated, is the red LED
lit steadily and does the
buzzer sound?
STOP pushbutton or one
of the movement
actuators are activated:
disconnect it/them.
Is the LED lit with a steady
light?
Does the red LED blink
and does the buzzer
sound?
The battery is discharged:
replace it with a fully
charged one. Does the
LED continue to blink and
the buzzer sounding?
Clean contacts in the bat-
tery housing. Does the
LED continue to blink and
the buzzer sounding?
Does the green LED
blink?
Carry out diagnostics
checks on the receiving
unit (see paragraph 9.2)
CALL TECHNICAL
ASSISTANCE
YES
NO
NO
YES
YES
YES
NO
NO
NO
NO
YES
YES
Содержание Modular series
Страница 1: ...Modular Series Master Slave system Master Master system User Manual ...
Страница 2: ......
Страница 3: ...Modular Series Master Slave system Master Master system User Manual ...
Страница 34: ...9 Diagnostics 30 LIMM SA0 00 fm ...
Страница 35: ......
Страница 36: ...Autec s r l Via Pomaroli 65 36030 Caldogno VI Italy tel 39 0444 901000 fax 39 0444 901011 www autecsafety com ...