3 Recei
v
ing unit
- 13 -
LIMM&SA0-00.fm
In this case, install the antenna in a vertical position, and possibly place it near
the work area.
Place the receiving unit so that it can be reached easily.
Fix the receiving unit in 4 points, using the specific holes in the housing and the
specific vibration dampers.
Do not modify or tamper with the radio remote control, the machine or its elec-
trical panel. Do not perforate the receiving unit in any case.
Check that the receiving unit power supply is within the voltage range given in
the “Technical Data”, and that the voltages and currents being used do not ex-
ceed the maximum permitted values.
Do not bypass the radio remote control safety devices and/or those present in-
side the machine.
Respect the IEC60204-32 (for hoisting machines) and/or IEC60204-1 prescrip-
tions (for machines).
Never power on the receiving unit directly from the mains. A main switch should
always be present to allow power supply removal.
Remember to carefully wire the SAFETY contact in series with the movement
commands inside the receiving unit.
After installation and wiring, always check that the manoeuvres carried out are
exactly the same as the commands given (in particular check the STOP com-
mand).
Group the wiring away from the radio modules in order to avoid interferences
and hazards related to electrical safety.
Never remove the jumper between the STOP-command contacts 2 and 3, unless
a circuit with 2 separate contacts (4 wires) is required. If removed, the STOP cir-
cuit could loose its safety functions.
When maintenance is carried out on the machine (i.e. when soldering), remove
power supply by disconnecting all electric connections (both during installation
and during normal operation).
The installer must CHECK and/or FILL IN the “Technical Data Sheet”, indicating the date the sys-
tem has been put into service, signing and stamping it.
Fuse
(wiring example)
common
input
Receiving unit
movement command
common wire
selection and/or
auxiliary command
common wire
Содержание Modular series
Страница 1: ...Modular Series Master Slave system Master Master system User Manual ...
Страница 2: ......
Страница 3: ...Modular Series Master Slave system Master Master system User Manual ...
Страница 34: ...9 Diagnostics 30 LIMM SA0 00 fm ...
Страница 35: ......
Страница 36: ...Autec s r l Via Pomaroli 65 36030 Caldogno VI Italy tel 39 0444 901000 fax 39 0444 901011 www autecsafety com ...