8. TROUBLE-SHOOTING
Search for the source of the fault, and carry out the necessary repairs only after all the necessary SAFETY REGULATIONS as described
have been taken into account.
i
ALL “RESETTING” ACTIONS, REPAIRS TO THE SAFETY ARRANGEMENTS AND ELECTRICAL COMPONENTS IN THE LIFT MUST BE
CARRIED OUT BY AUTHORISED PERSONNEL ONLY.
PROBLEMS
POSSIBLE REASONS
REMEDIAL ACTION
•
The lift does not move upward when the lifting
button is pressed
The main switch is off
The fuse has burnt out
•
The lift is overloaded
•
Switch on the main switch
•
Replace the fuse
•
Maintain the weight according to the specifications
•
The switch is not working
•
Replace the switch, and call Autec
•
Fault in the electrical system
•
The direction of rotation of the motor is
wrong
•
Insufficient hydraulic oil
•
Suction pump is choked
•
The emergency stop button has been
pressed
•
Call up the Autec service department
•
Switch the phase wires
•
Fill in hydraulic oil
•
Clean the suction pump
•
Turn the emergency stop button off
•
The lift rises only partially
The thermal protection keeps tripping
•
Re-set the thermal protection
The lifting bridge is overloaded
•
Maintain the weight according to the specifications
•
Voltage too low
•
Insufficient hydraulic oil
•
Suction pump is choked up
•
Check the voltage
•
Fill in hydraulic oil
•
Clean the suction pump
•
The lift does not come down when the button for the
downward motion is pressed
•
Foreign object under the lifting table
•
Fault in the electrical system
•
The downward motion button is soiled
•
The downward motion solenoid valve is not
working properly
•
The emergency stop button has been
pressed
•
Remove the foreign object under the lifting table
•
Call up the Autec service department
•
Replace the downward motion button
•
Call up the Autec service department
•
Turn the emergency stop button off
•
The lift goes down in jerks
•
The lifts sink back to the original position
•
The platforms do not align properly
•
There is air entrapped in the hydraulic
system
•
There is a leakage in at least two hydraulic
system pipelines
•
The hydraulic cylinders are dirty
•
The non-return valve is leaking
•
Several possible causes
•
Air the system
•
Call up the Autec service department
•
Call up the Autec service department
•
Call up the Autec service department
•
Call up the Autec service department
DETAILS REQUIRED WHILE CALLING AUTEC SERVICE.
If you are reporting a fault, try to provide at least the following data :
n
The serial number, the type and the year of manufacture of the lift.
ORDERING SPARE PARTS
For ordering spare parts, please refer to the following Technical Instructions Book-pages which will be supplied on request :
uni/TE-ASLP 3005-01 tm 11
ACCESSORIES ASLP 3005
The set of extension pieces ASH-3005/A5 and the set of plates for sliding cars onto and down from the lift type ASLP-3005/A8 can be
supplied on an optional basis along with the ASLP3005 lift. The set of extension hoses is used if the hoses generally supplied do not reach
all the way upto the control cabinet. The plates for sliding cars onto and down from the lift are used in vehicles which have a very low road
holding capability.
ASH-3005/A5
ASLP-3005/A8