11 | Installation
EN
Operating manual Fireplace inserts S3
64
1
Fig. 53:
Installing the installation kit
8) Install the installation kit (1) as shown.
ð
After installing the installation kit, check the free
movement of the air regulator.
9) To do so, move the air regulator several times from
the minimum position to the maximum position.
Should there be no free movement of the air regu-
lator, check the following:
ð
Has the installation kit been correctly installed.
ð
Are the screw joints on the air regulator disc ex-
cessively tightened?
If the air regulator can be easily adjusted, the assembly of
the connection between installation kit and control unit can
be continued.
1
2
3
Fig. 54:
Installing the control unit
10) Remove the two M10x1 (1) and the M5 nut with flange
(2) and the spacer connecting plate (3).
For the connection between control unit and installation kit
you will require the following part from the installation kit:
• 2 x Taptite hex. LKS M5x10
• 2 x flange Bowden cable
• Torx screwdriver (not included in the scope of delivery)
The installation point of the control unit must be chosen so
that the following items are guaranteed:
• The ambient temperature of the control unit must not
exceed 50°C.
• The control unit must be accessible.
• A maximum of 2 curves must be laid with the Bowden
cable.
• The curve radius of the Bowden cable must not be smal-
ler than 100 mm.
1
Fig. 55:
Threading the Bowden cable
11) Thread the Bowden cable (1) through the hole in the
fireplace insert.