27
Possible alerts – color codes
Color code for Alert A004
Color code for Alert A006
Color code for Alert A007
Description
WEAK BATTERY.
Comment
The MAIN BOARD of your stove does have a C2032 Bat-
tery to be able to save the following data: Timers, Time,
Date. If the Battery gets weak this ALERT is displayed.
Solution
Replace the Battery (Be aware. Any new stove does
come with a protected Battery. Draw the BATTERY
PROTECTION when the new stove gets installed. The
Alert will be gone prompt).
Description
The DIFFERENCE PRESSURE SYSTEM of your
stove is disturbed.
Comment
This alert does show up when the HOPPER LID stays open
during operation for more than 255 seconds ( BE AWARE:
When the AUGER SHAFT is empty – i.e.: Stove gets installed
for the first time the augershaft got cleaned, … you have to fill
up the auger shaft for a proper operation manual by pushing the
RESET KNOB. To get access to this knob you have to open the
HOPPER LID. After 255 seconds this error will show up. There-
fore we recommend to close the lid before 255 seconds have
passed and start the manual feeding procedure a second time.
Solution
Close the Hopper Lid in time.
Description
The DIFFERENCE PRESSURE SYSTEM of your
stove is disturbed.
Comment
This alert does show up when the TUBES of the
DIFFERENCE PRESSURE SYSTEM are bad or
not connected proper.
Solution
Check the Tubes.