30
Mögliche Fehler – Farbcodes
Color code for Error E114
Color code for Error E115
Color code for Error E113
Description
Too few pellets drop into the BURN POT. That
causes a temperature drop in the Fire Box. As a
result the stove shuts off.
Comment
The auger does not feed enough pellets.
Solution
1. Check the Fuel Level in the Hopper.
2. Clean the Auger Shaft of dust.
Description
Controller can`t load the Operating System Files.
Comment
This Errror mainly shows up after POWER FAI-
LURE.
Solution
An AUSTROFLAMM AUTHORIZED TECHNICIAN
has to save the software on the CLOU CONT-
ROLLER again.
Description
The Temperature inside the FIRE BOX or the
EXHAUST CHANNELS is too high.
Comment
The FLAME SENSOR does not modulate correct
or DIRT does block the exhaust.
Solution
Call an authorized Austroflamm Service
Technician to take care of this problem.