Id. no.: 242440-7
9
Manual mode
In this mode the hot water temperature is kept constant.
The following table provides and overview of the approximate temperatures in the tank:
Level
Selection
Temperature
1
~57°C
2
~62°C
3
~67°C
4
~72°C
5
~75°C
A flashing shower symbol indicates that the water is being heated-up.
Legionella protection circuit
This circuit reduces the risk of bacterial growth in the tank.
As soon as tank has been properly installed, a programme monitors the tank temperature. When unfa-
vourable conditions are detected, a protection cycle is automatically started and the water is heated up
to 65°C.
If the system is in holiday mode and a protection cycle is required, this is only started at the end of the set
holiday for energy saving reasons.
Child lock
The button functions can be locked to prevent unintentional adjustment of the settings. To switch the but-
ton lock on or off, press the [+] and [-] buttons simultaneously for at least 3 seconds.
Display backlighting
The display backlighting is activated after switching on the system, or pressing any button. The backlight-
ing goes off after 10 seconds.