PRODUCT DATA ERP

Model

ECO CLEVER

80

100

120

150

Storage tank volume

l

80

100

120

150

Mixed water volume

V

40

122

152

183

228

Load profile

M

M

M

M

Energy efficiency grade

B

B

B

B

Energy efficiency

%

39.8

38.9

38.3

38.7

Daily electricity consumption

Q

elec

6.039

6.220

6.330

6.248

Annual electricity consumption 

kWh

1316

1347

1366

1352

Power consumption with smart

Q

elec-week-smart

30.195

31.100

31.650

31.240

Power consumption without 
smart

Q

elec-week

35.875

36.785

37.835

39.375

Temperature setting of the tem-
perature regulator

°C

65

65

65

65

Sound power level indoors

dB

15

15

15

15

Special precautions

See Manual

See Manual

See Manual

See Manual

Comments

The values stated are guide values, measured in accordance with the specifications of the ErP (energy-re-
lated products) Directive.
The actual values depend on the individual circumstances (number of people in the household, sanitary 
fittings in the flat or house, plumbing insulation, etc.) and can therefore deviate from the values stated.

DOMESTIC HOT WATER SIDE CONNECTION (PRESSURE RESISTANT)

In cases in which unsuitable or non-functional storage tank connection fittings are used as well as in cas-
es in which the stated operating pressure is exceeded, we shall refuse to guarantee the water heater in 
any way whatsoever. All tanks and boilers which have the description “max. operating pressure 6 bar” or 
“max. operating pressure 10 bar” on the rating place are pressure resistant tanks. The connection and/or 
connection components (e.g. safety valve, pressure reducer) must be designed and dimensioned accord-
ing to national standards and regulations (e.g. DIN 1988-20; ÖNORM EN 806-2). 

Warning: The pipe water pressure must be suitable for the safety valve. If necessary, install a pres-

sure reducer. The water connection must only take place via a certified membrane safety valve or a 

membrane safety valve combination - connection fitting for pressure resistant storage tanks.

A safety valve combination consists of shut-off, back-flow, drainage and safety valves with expandable 
water outlet and is installed between the storage tank's cold water inlet pipe (blue) and cold water inlet in 
an appropriate sequence.

Speicher

Sicherheitsventil

Entleerungsventil

Rückflussverhinder

er

Prüfventil

Druckminderventil

Absperrventil

Gebrauchsarmatur

en

Содержание eco clever 100

Страница 1: ...Operating and Installation Instructions ECO CLEVER Please forward this on to the user Id no 242440 7 Pressure resistant electric water heater 80 100 120 150 Litres...

Страница 2: ...gy consumption For the sake of the environment the ARA Junk Recycling Austria AG licence enables you to have the packaging of your device professionally disposed of The installation and initial commis...

Страница 3: ...lay backlighting 9 Error codes 10 Troubleshooting 11 Control unit 12 Operating Requirements 13 Installation and Safety Information 13 Dimensions Sketch 15 Product Data ErP 16 Domestic Hot Water Side C...

Страница 4: ...rface install supporting feet depending on the type Ensure that the subsurface at the installation location has a sufficient load bearing capacity The storage tank may only be set up in dry frost prot...

Страница 5: ...ew standard values for consumption The temperature of the cold water required for mixing for the stated hot water temperature was assumed to be approx 12 C SAVING ENERGY Our electrical storage system...

Страница 6: ...CONTROL SYSTEM LCD VERSION Operation The LCD controller has 3 push buttons which can be used to select the desired operating mode This button is used used to select between the 3 different operating m...

Страница 7: ...mode after the set days have elapsed The level of comfort and the number of holiday days can be set using these buttons If the tank is correctly installed and filled completely with water the electric...

Страница 8: ...g 1 2 3 recommended standard setting 4 5 Comfort level 3 complies with the requirements of prEN 15440 and corresponds to 80 of the possible hot water content 3 seconds after you have selected the leve...

Страница 9: ...e monitors the tank temperature When unfa vourable conditions are detected a protection cycle is automatically started and the water is heated up to 65 C If the system is in holiday mode and a protect...

Страница 10: ...ry operation There is no water in the tank 2 Unexpectedly long heating duration There are several possible causes Defective heating element Defective relay Uncontrolled water leakage Increased hot wat...

Страница 11: ...de 6 Data connections Disconnect the tank from the power supply Check the data cables and replace if necessary Nothing appears on the display when power is ON Attention Only for specialists Check the...

Страница 12: ...N Tank heating up Rapid flashing ON 1s OFF 1s Error detected Rapid double flashing upon starting 2x ON 0 5s 2x OFF 0 5s during power up Confirmation that the device is in the standard setting Reset af...

Страница 13: ...take notice of this warning could result in personal injury due to a falling device b Every device is delivered with a wall rail for the insertion of the upper securing hook which is attached to the w...

Страница 14: ...nce with good engineering practice We recommend the installation of insulating screw fixings h If there is particularly aggressive water which demands a special solution on the installation side the p...

Страница 15: ...t in kg H A B B adjustable from to 80 Hanging storage tank 751 280 400 400 550 40 100 Hanging storage tank 884 280 600 400 700 46 120 Hanging storage tank 1019 280 600 550 850 52 150 Hanging storage t...

Страница 16: ...SSURE RESISTANT In cases in which unsuitable or non functional storage tank connection fittings are used as well as in cas es in which the stated operating pressure is exceeded we shall refuse to guar...

Страница 17: ...queued water is drained off completely via the funnel or outlet pipe b In the event safety valves are installed before water heaters a check should be made as to whether the safety valve reacts when...

Страница 18: ...ith a contact opening width of 3mm is to be provided in the electrical supply line Automatic circuit breakers are also permissible as isolators d The connection cable must be inserted into the connect...

Страница 19: ...cold weather season if the device will be out of action for several days and is not being operated in frost protection mode The draining of the domestic water is carried out once the shut off valve ha...

Страница 20: ...escale with a wooden instrument and then take out with a vacuum cleaner or wipe it out with a cloth The device must then be thoroughly rinsed in accordance with NORM H5195 and the heating up process i...

Страница 21: ...and non functioning operating fittings glass or plastic part breakage any colour differences damage through improper use particularly by failing to observe the operating and assembly instructions oper...

Страница 22: ...have been fulfilled This includes for example the mandatory and documented replacement of the anode connection to the correct operating voltage damages arising from improper operation are to be avoide...

Страница 23: ...Id no 242440 7 23 NOTES...

Страница 24: ...x 03512 700 239 Internet www austria email at E mail office austria email at Austria Email in your area For addresses and telephone numbers of our subsidiaries visit our homepage at www austria email...

Отзывы: