16
Id. no.: 242440-7
PRODUCT DATA ERP
Model
ECO CLEVER
80
100
120
150
Storage tank volume
l
80
100
120
150
Mixed water volume
V
40
122
152
183
228
Load profile
M
M
M
M
Energy efficiency grade
B
B
B
B
Energy efficiency
%
39.8
38.9
38.3
38.7
Daily electricity consumption
Q
elec
6.039
6.220
6.330
6.248
Annual electricity consumption
kWh
1316
1347
1366
1352
Power consumption with smart
Q
elec-week-smart
30.195
31.100
31.650
31.240
Power consumption without
smart
Q
elec-week
35.875
36.785
37.835
39.375
Temperature setting of the tem-
perature regulator
°C
65
65
65
65
Sound power level indoors
dB
15
15
15
15
Special precautions
See Manual
See Manual
See Manual
See Manual
Comments
The values stated are guide values, measured in accordance with the specifications of the ErP (energy-re-
lated products) Directive.
The actual values depend on the individual circumstances (number of people in the household, sanitary
fittings in the flat or house, plumbing insulation, etc.) and can therefore deviate from the values stated.
DOMESTIC HOT WATER SIDE CONNECTION (PRESSURE RESISTANT)
In cases in which unsuitable or non-functional storage tank connection fittings are used as well as in cas-
es in which the stated operating pressure is exceeded, we shall refuse to guarantee the water heater in
any way whatsoever. All tanks and boilers which have the description “max. operating pressure 6 bar” or
“max. operating pressure 10 bar” on the rating place are pressure resistant tanks. The connection and/or
connection components (e.g. safety valve, pressure reducer) must be designed and dimensioned accord-
ing to national standards and regulations (e.g. DIN 1988-20; ÖNORM EN 806-2).
Warning: The pipe water pressure must be suitable for the safety valve. If necessary, install a pres-
sure reducer. The water connection must only take place via a certified membrane safety valve or a
membrane safety valve combination - connection fitting for pressure resistant storage tanks.
A safety valve combination consists of shut-off, back-flow, drainage and safety valves with expandable
water outlet and is installed between the storage tank's cold water inlet pipe (blue) and cold water inlet in
an appropriate sequence.
Speicher
Sicherheitsventil
Entleerungsventil
Rückflussverhinder
er
Prüfventil
Druckminderventil
Absperrventil
Gebrauchsarmatur
en