YL-250 5000KG 2 BASE PLATE CAR HOIST
Installation and operation manual
25
DANGER
DANGER
NOTE:
CAUTION NEVER OPERATE THE MOTOR ON LINE VOLTAGE LESS THAN 208V. MOTOR DAMAGE MAY OCCUR WHICH IS NOT
COVERED UNDER WARRANTY. HAVE A CERTIFIED ELECTRICIAN RUN APPROPRIATE POWER SUPPLY TO MOTOR. SIZE WIRE
FOR 25 AMP CIRCUIT. SEE MOTOR OPERATING DATA TABLE. USE SEPARATE CIRCUIT FOR EACH POWER UNIT. PROTECT
EACH CIRCUIT WITH TIME DELAY FUSE OR CIRCUIT BREAKER. FOR SINGLE PHASE 208-230V, USE 25 AMP FUSE. THREE
PHASE 208- 240V, USE 25 AMP FUSE. FOR THREE PHASE 400V AND ABOVE, USE 15 AMP FUSE. ALL WIRING MUST COMPLY
WITH NECK AND ALL LOCAL ELECTRICAL CODES.
CARRIAGE STOP BOLT INSTALLATION WARNING
IMPORTANT POWER UNIT INSTALLATION NOTES
• Do not run hydraulic power unit without oil. Damage to pump can occur.
• The power unit must be kept dry. Damage to power unit caused by water or other liquids such as
detergents, acid etc. is not covered under warranty.
• Improper electrical connection can damage motor and will not be covered under warranty.
• Motor can not run on 50HZ without a physical change in the motor.
• Use a separate breaker for each power unit.
• Protect each circuit with time delay fuse or circuit breaker.
• For 240 volt, single phase use a 25 amp fuse.
• For 240 volt, three phase use a 20 amp fuse.
• For 415 volt, three phase use a 15 amp fuse.
INSTALLATION AND ADJUSTMENT
DO NOT attempt to raise vehicle until a thorough operation check has been completed.
ALL WIRING MUST BE PERFORMED BY A CERTIFIED ELECTRICIAN ONLY
POWER UNIT CONNECTION
Have a certified electrician run the power supply to motor.
Refer to the data plate found on the motor for proper power supply and wire size.
RISK OF EXPLOSION
This equipment has internal arcing or parts that may spark and should not be exposed to flammable vapors. Motor should not be located in a
recessed area or below floor level. NEVER expose motor to rain or other damp environments.
DAMAGE TO MOTOR CAUSED BY WATER IS NOT COVERED UNDER WARRANTY.
YOU MUST RE-INSTALL BOLT/TIGHTEN BOLT OF TORQUE UPON FINAL INSTALLATION INSPECTION. THESE INSTRUCTIONS MUST BE
FOLLOWED TO ENSURE PROPER INSTALLATION AND OPERATION OF YOUR LIFT. FAILURE TO COMPLY WITH THESE INSTRUCTIONS CAN
RESULT IN SERIOUS BODILY INJURY AND/OR DEATH AND/OR VOID PRODUCT WARRANTY. MANUFACTURER WILL ASSUME NO LIABILITY FOR
LOSS OR DAMAGE OF ANY KIND, EXPRESSED OR IMPLIED RESULTING FROM IMPROPER INSTALLATION OR USE OF THIS PRODUCT.
WARNING
DO NOT PERFORM ANY MAINTENANCE OR INSTALLATION OF ANY COMPONENTS WITHOUT FIRST ENSURING THAT ELECTRICAL POWER
HAS BEEN DISCONNECTED AT THE SOURCE OR PANEL AND CANNOT BE RE-ENERGIZED UNTIL ALL MAINTENANCE AND/OR INSTALLATION
PROCEDURES ARE COMPLETED.
HIGH-LIFT