Aurora THE AETHER Скачать руководство пользователя страница 19

installation

 

and

 

user

 

manual

34

operation

 

and

 

maintenance

5

WHAT YOU SHOULD BURN

·    · 

·

Untreated, air dried hardwood

·    · 

·

Split logs with a humidity content of less than 20% 

DO NOT BURN

·    · 

·

Trash

·    · 

·

Painted plastic

·    · 

·

Coated or preservative treated wood

·    · 

·

Waste or black coal

·    · 

·

Flamable liquids such as naphtha, engine oil  

or gasoline

·    · 

·

Fire gels

·    · 

·

Moist wood with a residual humidity content of 

more than 20%.

Trouble Shooting: Please get in touch with us on the 

details below or refer to our FAQ page for trouble 

shooting on the operation of your firebox: 

www.aurorasuspendedfires.com/support/faq/

important

 

Burning incorrect fuel such as those listed above can 

generate toxic fumes and carbon monoxide resulting in 

serious illness or death if inhaled. 

If you have smoke detectors, prevent smoke spillage as 

this may set off a false alarm.

Misuse may lead to unhealthy and environmentally harmful 

emissions and will void any warranty or guarantee. 

 

Burning only seasoned hardwood helps to protect the 

environment and lower emissions.

OPERATION

35

·    · 

·

Do not use flammable liquids or aerosols to start or 

rekindle the fire.

·    · 

·

Do not use flammable liquids or aerosols in the 

vicinity of this appliance when it is operating.

·    · 

·

Do not store fuel within heater installation clearances.

·    · 

·

This appliance should be maintained and operated 

at all times in accordance with these instructions.

·    · 

·

The use of some types of preservative-treated wood 

as a fuel can be hazardous.

·    · 

·

Do not touch the firebox or flue when hot. 

 

OVER FIRING 

 

DO NOT OVER-FIRE. 

Over-firing may damage the fire and the paint.

To Prevent Over-Firing, DO NOT:

·    · 

·

Use flammable liquids

·    · 

·

Overload with wood

·    · 

·

Burn trash or large amounts of scrap lumber 

SYMPTOMS OF OVER-FIRING

Symptoms of over-firing may include one or more of the 

following:

·    · 

·

Flue or appliance glowing

·    · 

·

Paint peeling or bubbling.

·    · 

·

Roaring, rumbling noises

!

important

 

Aurora Suspended 

Fires WILL NOT 

warranty fires that 

exhibit evidence of 

over-firing. Evidence 

of over-firing includes, 

but is not limited to: 

bubbling, cracking and 

discolouration of steel 

or painted finishes.

Hot while in operation. 

Keep children, clothing 

and furniture away. 

Contact may cause 

skin burns.

Never use gasoline, 

gasoline-type lantern 

fuel, kerosene, charcoal 

lighter fluid, or similar 

liquids to start or 

‘freshen up’ a fire in this 

fireplace. Keep all such 

liquids well away from 

the fireplace while it is 

in use.

!

!

Содержание THE AETHER

Страница 1: ...61 0 2 6686 8408 4 1 Simmons Street Ballina NSW 2478 Australia UNITED STATES CANADA Wood Fires KEEP THESE INSTRUCTIONS FOR FUTURE USE Tested by OMNI Test Laboratories and certified to UL 737 2011 R201...

Страница 2: ...EBOX 21 FLOOR PROTECTOR REQUIREMENTS 23 FOR INSTALLERS 25 INSTALLATION CHECKLIST 26 4 CARING FOR YOUR PAINT 27 INITIAL START UP 28 CLEANING MAINTAINING YOUR PAINT 30 CARING FOR YOUR OUTDOOR FIREPLACE...

Страница 3: ...qualified professional Contact your local building or fire officials about restrictions and installation inspection requirements in your area WARNING NOT FOR MOBILE HOME INSTALLATION DO NOT CONNECT T...

Страница 4: ...8 2kW Colour matte black A range of other colours are available on request For more information download our colour chart WEIGHT DIMENSIONS 357 16 357 16 THE HEARTH FEATURES Stainless steel ball beari...

Страница 5: ...es can be treated as non combustible REDUCING CLEARANCE TO COMBUSTIBLES Clearances may only be reduced by means approved by the regulatory authority Please refer to the Installation Planning section o...

Страница 6: ...84 semi rigid aluminium duct minimum fresh air intake size MINIMUM TOTAL FLUE LENGTH SUSPENSION BRACKET LOWER ACTIVE FLUE DAMPER HANDLE INTERNAL ROTATION ASSEMBLY FIREBOX GRATE ASH REMOVAL TRAY To gua...

Страница 7: ...d Equipment WARNING The chimney and chimney connector must be in good condition and be kept clean FLUE HEIGHTS TERMINATION The minimum flue height recommended for optimum performance of our fireplaces...

Страница 8: ...urora suspended fires 13 12 3 INSTALLATION PLANNING 2 LESS THAN 10 RIDGE 10 TO NEAREST ROOFLINE PITCHED ROOF Minimum Flue Height 3 MINIMUM 3 MINIMUM 2 10 OR MORE LESS THAN 10 3 MINIMUM 3 MINIMUM 2 MIN...

Страница 9: ...iling This gap will be covered by the ceiling cover plate 1 2 ventilation gap between the plasterboard and the ceiling cover plate 1 2 minimum clearance from the insulated flue to any combustible mate...

Страница 10: ...rect distance of the firebox to the floor FLUE LENGTHS 5 3 9 1 5 11 9 9 6 7 10 8 7 5 11 6 8 3 Custom Sizes above 11 6 will come in two pieces with an internal joiner INSTALLING THE INTERNAL LOWER ACTI...

Страница 11: ...NG THE ADAPTOR 1 Push the the adaptor into the top of the lower active flue as far as it will go until it bottoms out Use high temperature silicon sealant to ensure a good seal 2 Install the insulated...

Страница 12: ...s usually a minimum of 2 although it may vary by manufacturer or for certain chimney components EXTERNAL FLUE ENGAGING THE FIREBOX FOR UNLOCKED FIRES WITH 360 DEGREE ROTATION Assemble the shaft bearin...

Страница 13: ...that you place a protective cloth over the lip of the firebox when inserting or removing the grate to prevent scratching the paint FLOOR PROTECTOR REQUIREMENTS You will require a floor protector to p...

Страница 14: ...ittle water and a scratch free glass polishing cloth DO NOT RUB THE PAINT A LIGHT PRESSURE IS ALL THAT IS NEEDED HANDING OVER CHECKLIST Read the Users instructions and instruct the user on the operati...

Страница 15: ...p of the lower active flue as far as it will go until it bottoms out sealed with a high temp silicone sealant If this is not done correctly it may result in a weak draw Flue adaptor sealed correctly I...

Страница 16: ...ace Once this initial firing process is successfully completed the coating will bond to the metal with a colourfast finish that will last important Initial startup is for your safety the longevity of...

Страница 17: ...OUTDOOR FIREPLACES Our outdoor fireplaces are coated with a zinc paint to prevent rust Extra care will ensure the longevity of your fireplace If you live near a beach or if your fireplace is installe...

Страница 18: ...ill damage the paint 1 Wipe all surfaces with a mild soap with a scratch free glass polishing cloth 2 Wipe dry with scratch free glass polishing cloth 3 Ensure surface is completely dry before lightin...

Страница 19: ...dle the fire Do not use flammable liquids or aerosols in the vicinity of this appliance when it is operating Do not store fuel within heater installation clearances This appliance should be maintained...

Страница 20: ...G OR HOUSE FIRE DAMAGE CAUSED FROM NON OBSERVANCE OF THIS CAUTION IS NOT COVERED UNDER AURORA WARRANTY Disposal of Ashes Ashes should be placed in a metal container with a tight fitting lid The closed...

Страница 21: ...bottom pieces of split timber 7 Once the timber is well alight start adding more 2 thick pieces of timber 1 or 2 at a time slowly increasing the timber size as the fire burns 5 TROUBLE SHOOTING Crack...

Страница 22: ...the fire and flue system Wind that hits the flue system may overcome the cowl and draft back down the flue Care must be taken to ensure that the flue termination is in the correct position to maximis...

Страница 23: ...nd ULC S627 00 CERTIFICATION US EPA EXEMPT installation and user manual certification warranty 6 EFFICIENCY testing laboratory KIWA GASTEC manufacturer Aurora Wood Fires Pty Ltd models The Aether The...

Страница 24: ...ctual or attempted repair work on the product has been carried out by anyone other than an Aurora Suspended Fires authorised service technician or where a repair used non genuine Aurora Suspended Fire...

Страница 25: ...61 0 2 6686 8408 4 1 Simmons Street Ballina NSW 2478 Australia www aurorasuspendedfires com Aurora...

Отзывы: