installation
and
user
manual
aurora
suspended
fires
21
20
installation
3
Aurora Fires must be connected to a chimney & anti-
downdraft cowl complying with the requirements
for Type HT chimneys in the standard for Chimneys,
Factory-built, Residential Type and Building Heating
Appliance, UL 103 / ULC S629. For example, a class A
insulated stainless steel flue chimney system with an
6-inch minimum inside diameter.
The chimney manufacturer’s installation instructions
must be followed precisely. Always maintain the proper
clearance to combustibles as established by the pipe
manufacturer. This clearance is usually a minimum of
2͈ , although it may vary by manufacturer or for certain
chimney components.
EXTERNAL FLUE
ENGAGING THE FIREBOX
FOR UNLOCKED FIRES WITH 360 DEGREE ROTATION
Assemble the shaft & bearing system in the following order:
1. Push thrust bearing over shaft.
2. Engage the firebox.
3. Push 2nd thrust bearing over shaft.
4. Fit bearing cap.
5. Fit washer.
6. Fit M12 nut & tighten.
7. Fit 2nd M12 nut & tighten.
8. Fit safety split pin.
notE
The bearing is shipped in
the correct order on the
shaft. The bearing must
be installed in the correct
order or the firebox will
be too loose.
LOWER FLUE
THRUST BALL
BEARING
THRUST BALL
BEARING
BEARING CAP
WASHER
M12 NUTS
SAFETY SPLIT PIN
FIREBOX SLEEVE
important
Ensure the threaded
shaft does not knock
against the firebox when
engaging. This can damage
the thread.