background image

 

 

User Guide 

IP SETUP 

   

Introduction 

The IP function allows the DXE-CAT-RX3C and DXE-CAT-RX3C-A to be controlled via LAN. In 

addition, the units can be set up with built in setup pages and even serve up web pages to 

remote devices on the network for control.   

 

Default IP 

The default IP out of the box is 192.168.1.10 static. Make certain to change the IP on the unit at 

a time or you will get collisions on the network. Each device must have a unique IP address. 

DHCP can be used but it is recommended to issue IP address based on the MAC address. This 

assures the DHCP does not reassign the IP address at a later time causing issues. Keep in 

mind the processor is on the TX unit so only the TX needs to be connected when you are doing 

the initial setup although having the RX will not affect the process and may be necessary only if 

the LAN is connected at the RX side. 

 

To access the settings via web browser use the units IP address/setup (ex. 192.168.1.10/setup) 

The default user name is admin and the default password is admin. 

 

In the event you lose your settings press and hold the setup button on the DXE-CAT-RX3C / 

RX3C-A for 3 seconds. This will restore the unit back to factory default. 

 

Usage 

Only serial port 1 will be used to communicate to the RX3 at a baud rate of 115200. This baud 

rate will be fixed but the ports for the RX3 must still be set up accordingly to the correct baud 

rate to match the device they are connected to. 

The !30PTL,x<cr> command must be sent first to pick which port (1 = HDBaseT or 2 = Local 

RS-232) before sending a serial command out a port.

  

 

Содержание DXE-CAT-RX3

Страница 1: ...i Manual Number 140703 Firmware v1 06 or higher USERS GUIDE DXE CAT RX3 Series HDMI HDBaseT CAT Extender with Audio De embedding Relays 2x35W Amplifier IP Control...

Страница 2: ...ended for a long period disconnect it from the power source Also follow these precautions Ventilation Do not block the ventilation slots if applicable on the product or place any heavy object on top o...

Страница 3: ...11 Port Settings Manual 13 Port Settings Push to Variable 14 Port Settings Telnet Server 15 Port Settings Telnet Client 16 Port Settings Push to Port 17 Port Settings Pass Through 18 SERIAL COMMANDS...

Страница 4: ...A or DXE CAT RX3C A x 1 DXE CAT E1 Wall Desk Mount Ears x 2 PS0077 1 24V DC 90 Watt Power Adapter x 1 Optional Accessories PS0053 1 or PS0080 1 24v DC 15 5 Watt power Supply PS0062 1 24v DC 24 Watt p...

Страница 5: ...ntegrated solution for rolling carts podiums and credenzas is possible with the DXE CAT family Being able to go the distance is important too and HDBaseT technology helps achieve that With a single CA...

Страница 6: ...ential Line Input Output for Audio Mixing HDMI Audio De Embedding Volume Control Audio Functions Remotely Controlled via Transmitter Unit or Optional IP IP Control Engine C Version Bi directional RS 2...

Страница 7: ...ith baud rate RX RS 232 Receive Blinking rate and intensity will vary with baud rate HDBT Lights when HDBaseT RJ 45 has proper connection between an RX TX pair Blinks when in sleep mode HDMI Will ligh...

Страница 8: ...line level output from the HDMI on the bottom The input and output are balanced capable The line input can be mixed with the line output for applications like wireless microphone receiver or paging U...

Страница 9: ...anded receiver make certain you do not exceed the 5v signal level limitation as some devices use 12v Failure to do so will result in damage When the DXE CAT TX2L is set for manual the only way to send...

Страница 10: ...the TX needs to be connected when you are doing the initial setup although having the RX will not affect the process and may be necessary only if the LAN is connected at the RX side To access the set...

Страница 11: ...for better security on the network especially if it is not private Reset Factory Defaults Once pressed a confirm screen will appear Once confirmed the unit will restore the default IP address and pass...

Страница 12: ...P settings if DHCP is not utilized If you use DHCP it is always recommended to use a switch that can map the MAC address to a defined IP address otherwise the IP address may change inadvertently at a...

Страница 13: ...sh information to Note If an Aurora control system is not used RPC Telnet or TCP is available Local Serial Port 1 Settings Baud Rate Date Size Parity and Stop bits are selected for the TX RS 232 port...

Страница 14: ...Telnet Server Unit will wait for external connection to pass and receive serial port data Pass Through Unit s TX RX serial ports are linked so any serial RX data will come out the TX on the other seri...

Страница 15: ...Manual With port processing session set to manual there will be no additional selections as the system is set to trigger the functionality with IP commands Ports will not pass data from the TX to RX...

Страница 16: ...Remote Session IP Address Enter the IP address the variable is to be sent to an Aurora control device Note the IP address overrides the Master Remote IP address Target RPC Variable Name Enter the vari...

Страница 17: ...rt Number Defaulted to Port 23 but can be changed to other port numbers Telnet Timeout Seconds Defaulted to no timeout but can be set to timeout and close the connection Telnet Protocol Default is Tel...

Страница 18: ...lted to Port 23 but can be changed to other port numbers Telnet Local Port Number Defaulted to Port 23 but can be changed to other port numbers Telnet Timeout Seconds Defaulted to no timeout but can b...

Страница 19: ...Enter IP address of serial port on another Aurora control device to target This will forward the serial data to any Aurora control system product It overrides the master Remote IP Target RPC Serial Po...

Страница 20: ...ws the serial ports on both the DXE CAT TX and DXE CAT RX to become a virtual cable link The serial receive of one unit will be sent to the serial transmit of the other unit IP commands will still for...

Страница 21: ...er Volume 30LMH x cr x 0 120 78dB to 0dB x or Vol increment or decrement in steps of 2 Line In Line Out Mixer Volume 30LML x cr x 0 120 78dB to 0dB x or Vol increment or decrement in steps of 2 Line O...

Страница 22: ...o 0dB Query HDMI Line Out Mixer Volume 30LMH cr Response 30LMHx cr x 0 120 78dB to 0dB Query Line In Line Out Mixer Volume 30LML cr Response 30LMLx cr x 0 120 78dB to 0dB Query Line Out Volume 30LVL c...

Страница 23: ...pecific serial port 1 Serial_Send Port Msg MaxWaitMS Sends a serial command to a specific port 1 2 MaxWaitMS The number of milliseconds allowed to complete the sending of the serial data before timing...

Страница 24: ...mes Response Tokens status 0 for Failure 1 for Success faultCode If status is 0 failure faultCode will be an integer representing a specific error This token is NOT returned if status is 1 success res...

Страница 25: ...lash AJAX etc can be served up using the units IP address or host name if NetBIOS is used Aurora has a free tool called YIPI available for download on the Aurora website to create webpages quick and e...

Страница 26: ...Data2 Shield Pin 9 TMDS Data0 Pin 16 SDA Pin 3 TMDS Data2 Pin 10 TMDS Clock Pin 17 DDC CEC Ground Pin 4 TMDS Data1 Pin 11 TMDS Clock Shield Pin 18 5 V Power Pin 5 TMDS Data1 Shield Pin 12 TMDS Clock P...

Страница 27: ...mitter runs much cooler 6 Intermittent Noise in image a Exceeding recommend distance relative to cable specification b Use shielded cable Sometimes external devices like radio transmitters can interfe...

Страница 28: ...filename is the name of the file containing the image to upload targetIP is IP address of target in ddd ddd ddd ddd format The tool uses UDP port 9 or port 49444 to force targeted devices into program...

Страница 29: ...24 36bit CAT 5e 6 6a 7 328ft 100m 1080p 60Hz 48bit CAT 6a 7 230ft 70m 1080p 60Hz 48bit CAT 5e 6 6a 7 500ft 152m 1080p 60Hz 24bit Long Reach Mode CAT 6 600ft 183m 1080p 60Hz 24bit Long Reach Mode CAT...

Страница 30: ...90 Watt Wall Supply for A models only Non A models can be powered through normal means and must be ordered accordingly 1x DXE CAT E1 Wall Desk Mount Ears with Screws 1x User Manual Options IR Receiver...

Страница 31: ...r similar This can affect distance and overall performance Below is a list of cables that have been officially tested with our products by the manufacturer of the cable West Penn Wire CAT 6 Shielded H...

Страница 32: ...en repaired and or altered by other than manufacturer or authorized service center or D The product s original serial number has been modified or removed or E External equipment other than supplied by...

Страница 33: ...t warranty extends to the original purchaser only and will be null and void upon any assignment or Aurora Multimedia Corp 205 Commercial Court Morganville NJ 07751 Phone 732 591 5800 Fax 732 591 6801...