56
Fault
Cause
Action
Front or Rear burner igniting
but Burner going out after 5
seconds.
Flame sensing failure.
Soot on flame sensing Rod.
Flame sensing Rod touching
ceramic Log.
Faulty Flame sensing Rod.
Fault in control box.
Clean off soot from flame
sensing Rod
Re-position ceramic Log.
Call Aurora service.
Call Aurora service.
Convection Fan Operation
Front or Rear Burner
operating.
L.E.D Light item 7-8-9 on
Front panel display not
coming on for Fan Speed.
Possible fault in thermistor
Call Aurora Service
L.E.D light items 7-8-9 on
Front Panel coming on but
convection Fan is not starting
up.
Possible faulty Fan Speed
capacitor.
Call Aurora Service.
Condensate pump when oper-
ating shutting down heater .
Condensate Pump running
continuously and not switch-
ing off.
Fault with condensate system.
Fault with condensate system.
Call Aurora Service.
Call Aurora Service.
Trouble Shooting Checklist