background image

                                                           RX-8L50SA70SF 

                                                                                                                                 Instruction Manual

 

The technical  features are subject to change without notice. AUREL S.p.A. does not assume responsibilities for any damages caused by the device’s misuse

 

 

 
AUREL S.p.A.

 Via Foro dei Tigli, 4 - 47015 Modigliana (FC) – ITALY                                                         Rev. A,  February 1st 2002 

Tel.: +390546941124 – Fax: +390546941660                                                                                                                Pag  1 of 4 

http://www.aurel.it

  -  email: 

[email protected]

 

 

RX-8L50SA70SF Receiver

 

RF superheterodyne digital data receiver, OOK (On-Off Keying) modulated, operating at the 868,3MHz 
frequency, with high sensitivity, selectivity and immunity to electromagnete interfering fields.  

 

Pin-out  

 

 

    

 

 

Connections

 

 

Pin 1  

+V Preamp. 

Connection to the +5V 

±

5% supply positive pole   

Pin 2-7-11 

Ground 

GND Connections: Internally connected to a single ground plate  

Pin 3 

Antenna 

50

 impedence antenna connection  

Pin 13 

Test Point 

Analog output of the demodulated signal. By connecting an oscillograph 
the entity and quality of the received RF signal can be seen.  

Pin 14 

Data Out. 

Receiver digital output. Apply loads over 10 K

 

Pin 15 

+V 

Connection to the +5V 

±

5% supply positive pole   

 

Technical features 

      

 

 

Min 

Typical 

Max 

Unity 

Remarks 

Working centre frequency  

 

868.3  

 

MHz 

 

Voltage supply   Vs 

4.75  

5  

5.25  

 

Absorbed current 

 

mA 

 

RF sensitivity 

-98 

-100 

-104 

dBm 

See note 1 

RF passband at –3dB   

 

600 

 

KHz 

 

IF passband at –3dB   

 

300 

 

KHz 

 

Output square wave 

 

 

KHz 

 

Output high logic level  

Vs-1.2 

 

 

See note 4 

Output high logic level  

 

 

Gnd 

See note 4 

RF spurious emissions in antenna  

 

 

-80 

dBm 

See note 2 

Switch-on time 

 

 

0.2 

See note 3 

Working temperature 

-20 

 

+80 

°

See Fig.4 

Dimensions

 

44.95 x 17.51 x 9.3 mm 

 

 

Note1:

  Values have been obtained by applying the test system as per Fig. 1. 

Note2:

  The RF emission measure  has been obtained by connecting the spectrum analyser directly to RX Pin 3. 

Note3:

  By switch-on time is meant the time required by the receiver to acquire the declared characteristics from the very moment the 

power supply is applied. 

Note4:

 Values obtained with 10K

 maximum load applied. 

 

 

The technical tests and reports have been carried out and obtained by the laboratories of :   

Messrs PRIMA RICERCA & SVILUPPO

 – via Campagna, 58 – 22020 Gaggino Faloppio (CO) - Italy 

 

15 

Lot (Week/Year) 
 
       Code 