RX-8L50SA70SF
Instruction Manual
The technical features are subject to change without notice. AUREL S.p.A. does not assume responsibilities for any damages caused by the device’s misuse
.
AUREL S.p.A.
Via Foro dei Tigli, 4 - 47015 Modigliana (FC) – ITALY Rev. A, February 1st 2002
Tel.: +390546941124 – Fax: +390546941660 Pag 4 of 4
http://www.aurel.it
- email:
Reference curves
Fig.4
Temperature-Work frequency variation curve
-2,5
-2
-1,5
-1
-0,5
0
0,5
-20 -10
0
10
20
30
40
50
60
70
80
Temperature [°C]
Work frequency [MHz]
The curve has been obtained bt the test system
shown in Fig.1.
5V supply, RF 868,3 MHz, -100dBm input
Fig.3
Frequence-Selectivity curve
-90
-80
-70
-60
-50
-40
-30
-20
-10
0
866,5 867,1 867,7 868,3 868,9 869,5 870,1
Frequency [MHz]
Selectivity [dB]