background image

Rev. 2/13 

AM12MF18-1

 

14 

 

 

 

 

 

ONE FULL YEAR 
 
WARRANTY   

 

This  product  is  warranted  for  one  year  from  the  date  of  purchase  against  defects  in  materials  and 
workmanship.    At our discretion, parts that prove to be defective will either be repaired or replaced, or the 
whole product will be replaced. In either case, a copy of your proof of purchase will be required. 
 
In  case  that  any  mechanical  or  electrical  repairs  are  required  during  the  warranty  period,  send  your 
complete product, postage or freight prepaid to the AURAMIST service center near you. Call the number 
below to get the nearest service center.     
 
This warranty does not include the air or water filters, which are expendable parts that can wear out from 
normal use within the warranty period.    This warranty applies for only 90 days if this product is ever used 
for commercial or rental purposes.     
 
 
The serial number, model number and manufacturing date code can be found on the label attached to the 
back of the power base assembly. 
You should record these numbers and the date of purchase and keep in a safe place for future reference. 
 
MODEL NUMBER: 

 

                XXXXX 

MFG DATE CODE: 

 

                XXXX 

SERIAL NUMBER: 

 

                XXXXXX 

DATE OF PURCHASE: 

                XX-XX-XX

 

 
CUSTOMER SERVICE NUMBER:  1-800-320-6478 
Website:  

 

 

 

 

 

www.auramist.com 

 
 
 

 
 

Warranty   

 

 

Содержание AM12MF18-1

Страница 1: ...INSTRUCTIONS CAUTION Before using this product read this manual and follow all safety rules and operating instructions Failure to comply with instructions could result in personal injury and or property damage IMPORTANT For replacement parts or assembly questions go to www auramist com or call 1 800 320 6478 ...

Страница 2: ...els on the misting fan before using Safety is a combination of common sense staying alert and knowing how this misting fan works Use this misting fan only as described in this manual To reduce the risk of personal injury or damage to the misting fan use only recommended accessories Understanding Safety Terminology DANGER If safety information is not followed someone will be seriously injured or ki...

Страница 3: ...g to the power source 12 If the misting fan is not working correctly has missing parts has been dropped damaged or dropped in water call an authorized service center for evaluation adjustment or repair WARNING IMPROPER CONNECTION OF THE EQUIPMENT GROUNDING CONDUCTOR CAN RESULT IN A RISK OF ELECTRICAL SHOCK CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO WHETHER THE O...

Страница 4: ... containing an electrical conductive substance 24 This product must be grounded If it should malfunction or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock This product is equipped with a power cord having an equipment grounding conductor and a grounding plug Plug into an appropriate outlet that is properly installed and grounded i...

Страница 5: ...Fan blade 1 3 Rear fan guard 1 4 Fan motor head assembly 1 5 Fan Pole 1 6 Water filter assembly 1 7 Air filter assembly 1 8 Power base assembly 1 9 Junction box cover 1 10 Filter Access Door 1 11 Power base pole 1 12 Screws ST3 9x16 16 13 Screws M5x16 2 Carton Contents ...

Страница 6: ...ligned to the fan pole hole fasten the fan pole assembly to the power base assembly with one M5x16 screw fig 3 5 Connect fan pole wire connector to power base wire connector be sure to push connectors fully together until locked Fasten the junction box cover to the fan pole assembly with the four 3 9x16 screws fig 4 6 Remove the protective covering and connect the air filter assembly and water fil...

Страница 7: ... manual before operating this product Place the misting fan on a level surface near an electrical outlet Place the misting fan out of reach of children Do not insert anything into the fan guards If moving the misting fan to a different location turn it OFF and unplug it from the socket Testing the GFCI 1 Put the plug into the grounded outlet the indicator light on the GFCI lights up fig 1 2 Turn t...

Страница 8: ...g 2 l Clean and clear any dirt or dust from the fan to prevent water contamination l Check that all water and air tube connections are secure l Remove fill cap on power base assembly and fill with CLEAN WATER through the basket filter until tank is filled to approximately 1 below the bottom of the basket filter l Add teaspoon of unscented chlorine bleach to the water tank approximately 5 drops per...

Страница 9: ...e the unit with a DRY or WET mist based on your needs l To increase the mist density wetness turn the mist control valve counter clockwise l To decrease the mist density dryness turn the mist control valve clockwise Operating Tips For dry climates increasing the water flow will provide maximum cooling results In humid climates a reduced water flow is recommended CUSTOMER RESPONSIBILITIES Read and ...

Страница 10: ...the filters fig 4 Reinstall filter access door fig 5 REPLACE FUSE WARNING ALWAYS UNPLUG THE POWER CORD BEFORE REPLACE THE FUSE Open fuse cover Slide open fuse access cover on top of attachment plug towards prongs fig 1 Remove fuse carefully use a proper tool small screwdriver or similar tool to take the fuse out of the fuse holder fig 2 fig 3 Risk of fire Replace fuse only with 5 Amp 125Volt fuse ...

Страница 11: ...er Replace cap and hand tighten Run system for 5 minutes with a WET mist The system is conditioned and ready for operation PROBLEM CAUSE CORRECTION Fan not running 1 Power cord is not connected 2 Switch is in the OFF position 3 The indicator light on the GFCI is out 1 Connect power cord 2 Switch fan on high medium or low Positions 3 Press RESET button on the GFCI if the indicator light does not li...

Страница 12: ...all hose connections for air leaks 5 Order and replace nozzle Mist is not balanced on three nozzle 1 Low water flow 2 Water hose leaks 3 Kinked water hose 1 Adjust the water flow control valve 2 Turn off mist fan motor and feel any air leaks on hoses 3 Check assembly to ensure hoses are routed installed correctly Exploded View ...

Страница 13: ...F16R 1 013 Pump Bushings 4 15 AM12MF18R 1 015 Water filter assembly 1 16 AM12MF18R 1 016 Air filter assembly 1 17 AM12MF18R 1 017 Water tank assembly 1 18 AM12MF18R 1 018 Wheel 2 19 AM12MF18R 1 019 Wheel shaft 1 20 AM12MF18R 1 020 Base cover 1 21 AM12MF18R 1 021 Power Cord Strain Relief 1 22 AM12MF18R 1 022 Base Plate 1 23 AM12MF18R 1 023 Base Feet 6 24 AM12MF18R 1 024 Power Base Fan Pole 1 25 AM1...

Страница 14: ...e center near you Call the number below to get the nearest service center This warranty does not include the air or water filters which are expendable parts that can wear out from normal use within the warranty period This warranty applies for only 90 days if this product is ever used for commercial or rental purposes The serial number model number and manufacturing date code can be found on the l...

Отзывы: