8
Membrane Filter (349004Z)
is the place where the reverse osmosis occurs.
A long film made of a semi-permeable material is wrapped onto a reel in two
layers. These two layers are merged together with a separator between the
edges of this film with two layers and it is closed to water passage. It is like a
closed long narrow bag except its end wrapped on the reel with rowed holes
that is on the end which allows clean water output only. This double layer
film is wrapped onto a reel. Through the separator film placed between the
windings, dirty water reaches all surfaces of this bag, clean water enters the
bag under pressure and taken from the outlet holes. While dirty water passes
by the film surfaces with a flow called cross-flow, a part of water passes through
the internal part of the film as clean water (Figure 3).
High Pressure Switch**
stops the pump when the pressure of the tank filled
with clean water reaches 2.6 bar (38 psi).
Clean Water Tank
inner surface is coated with a "food contact" plastic material
suitable for food and enables clean water to be stored in a hygienic environment.
Tank Valve controls the water inlet and outlet to/from the tank.
Mineral Carbon Filter (340005Z06)
provides mineral to the clean water collected
in tanks or directly from the membrane before if flows from the faucet, enriches
the water and regulates the pH. THROTTLE ensures formation of required pressure
in the membrane by restricting flow so that the membrane can perform the
separation process. It is located on the line where the waste water is drained.
Clean Water Faucet
is where clean water is taken.
Pump Adapter**
is the power supply of the pump, it converts the mains
voltage to 24 V DC.
Fields of Use
Solenoid Valve*
controls the flow of water. When the water pressure in the tank
reaches a certain value, it closes the water inlet and prevents water being consumed
unnecessarily.
Digital Display*
is used for tracking the life of each filter based on the water passed
throug the filters. When the filter life is over, the water is cut or in case of a water
leakage it alerts the user.
Flow meter*
is used in determining the amount of water passing through the filters
and monitoring the current flow rate.
Water Leakage Sensor*
detects water leakage and blocks the water inlet of the system.
Water Leakage Shut off
Closes the water inlet mechanically in case of water leakage.
* Applicable for 101 ME model.
** Applicable for 101 ME and 101 MD models.
*** Applicable for 101 MD and 101 FG models.
This appliance is used to obtain drinking water from the mains water that have
passed through the municipal treatment processes. This water should be microbio-
logically safe, subjected to the necessary disinfection.
If the parameters of the water are within the following ranges efficient operation
of the appliance is ensured. Systems designed differently for waters such as sea
water, well water, muddy water etc. with a very high TDS value are also available.
40 psi-145 psi / (2,8 bar-10 bar) / (275 kPa - 1.000 kPa)
3-11
MAXIMUM FE
0,2 (ppm=mg/L)
MAXIMUM TDS
1250 (ppm=mg/L)
5 NTU
5
˚
C - 38
˚
C / (38
˚
F - 100
˚
F)
TEMPERATURE
OPERATING PRESSURE
PH RANGE
TURBIDITY
17
˚
Fr-10
˚
dH - 170 mg/L CaCO3
HARDNESS
# Max. pressure matches the structural integrity test value of NSF/ANSI Standard 58 for 101ME model