Aura Cebilon Скачать руководство пользователя страница 14

Figure 9 a

Figure 9 b

Figure 9 c

Figure 9 d

Figure 9 e

Substance

Total dissolved 

solids (TDS)

750 

± 40

770

30

96.0%

187

Influent Challenge 

Concentration

Average

Influence

(mg/L)

Average

Effluent

(mg/L)

Average % 

Reduction

Maximum permissible 

product water 

concentration (mg/L)

Maintenance of your appliance must be 

performed by an Authorized Service, 

appliances that of the maintenance is not 

performed by an Authorized Service 

will fall out of warranty.

The life of the filters used in Aura Cebilon 

Reverse Osmosis System changes depending 

on various factors with the amount of water 

used. These major factors are inlet water 

quality, chlorine amount, residue amount 

etc. Filters are considered as supplies and 

they are out of warranty.

Maintenance

Filter Replacement

• Pull the front cover towards yourself. 

(Figure 9a)

• 

The filter to be replaced is lifted up 30 

degrees. (Figure 9b). Then, it is turned to 

left 90 degrees and removed (Figure 9c).

• 

The new filter is fitted by turning 90 

degreesto the right (Figure 9d). Then, it is 

lowereddown 30 degrees to its former 

location.(Figure 9e)

• 

The front cover is fitted back.

The ball valve and the tank valve in the 

appliance are closed respectively before

the filter replacement. The pressure in

the system is removed by opening the

faucet of the appliance. Filter 

replacement is carried out after the E0

error appears on the screen and after 

the alarm sounds. (for 101 ME model)

After the filter replacement process is 

finished, the ball valve is opened 

respectively. When water starts to

come from the faucet, tank valve

opens and the faucet is closed.

Warning 

Performance 

Data Sheet

101ME model system conform to NSF/ANSI 

58 for the specific performance claims as

verified and substantiated b test data.

•  Do not use this system with any water that 

is microbiologically unsafe, that does  not 

have adequate disinfection before or  after 

operation or that of the quality is unknown. 

•  Aura Cebilon Reverse Osmosis System 

contains critical components that are 

required to be replaced periodically to purify 

the total dissolved solid materials (TDS). To 

check the efficiency of the system, water 

from the appliance must be tested 

periodically.

•  Your appliance contains critical 

components that must be replaced 

periodically with respect to the system's 

efficiency. These critical components must be 

replaced with components and filters with 

the specifications defined by the 

manufacturer so that the system can operate 

continuously with the same efficiency and 

performance.

Filter must not be replaced when inlet

water is open and without removing 

the pressure in the appliance.

101ME has been sested according to 

NSF/ANSI 58 for reduction of substances 

listed below. The concentration of the 

indicated substances in botter entering 

the system was reduced to a concentration 

less than or equal to the permessible limit 

for water leaving the system, as specified 

in 

NSF/ANSI 58. Testing was performed under 

standard laboratory conditions, actual 

performance vary.

14

Содержание Cebilon

Страница 1: ...101ME Tested and Certified by NSF International NSF ANSI Standard 58 for the Reduction Claims Specified on the Performans Data Sheet DIGITAL WITH PUMP WITH OUT PUMP User Manual...

Страница 2: ...lease read the entire user manual carefully and keep it as a reference Dear Customer Our manual contains information about the technical and hardware features of three di erent models The appliance yo...

Страница 3: ...E FAUCET REVERSE OSMOSIS RO WATER PURIFICATION SYSTEMS WASTE WATER CONNECTION PRE TESTS POINTS FOR ATTENTION MAINTENANCE FILTER REPLACEMENT PERFORMANCE DATA SHEET FILTER REPLACEMENT PERIODS CEBILON PA...

Страница 4: ...trations while the water molecules pass through the pores the solid particles with a large size cannot pass Since there are more water molecules in the water with low concentration and as a result mor...

Страница 5: ...rane pre ltration processes such as sediment lter carbon lter are carried out to retain the coarse residues and the chlorine used in the water disinfection Components such as these lters used before a...

Страница 6: ...6 8 6 Parts and Functions Figure 2 RO System Diagram Abwasser Waste Water A Cable Connection Colours White Adapter B Red Solenoid Valve C Green Pump D Yellow Low Pressure Switch E Blue High Pressure S...

Страница 7: ...the water clear Automatic Shut o Valve controls the ow of water If the system continues to run after the tank is full the water is wasted as a waste This is an undesirable condition Water should be cu...

Страница 8: ...the waste water is drained Clean Water Faucet is where clean water is taken Pump Adapter is the power supply of the pump it converts the mains voltage to 24 V DC Fields of Use Solenoid Valve controls...

Страница 9: ...ce s tank capacity is 8 litres approximately 2 2 gallons BOX SIZE mm 580x277x450 8 L 100 psi 689 kPa TANK CAPACITY 6 7 psi 40 48 kPa AIR TANK PRESSURE 75 15 gpd 284 47 L day DAILY CAPACITY 85 98 PURIF...

Страница 10: ...form protective membrane solution Install the tube that has flow restrictor on it but not to install the tube that goes to post carbon filter Allow water flow for 2 3 minutes to clear the membrane sol...

Страница 11: ...sser Waste Water 11 8 2 7 6 3 4 5 1 Figure 4 RO Installation Diagram 1 Cebilon 2 Water Inlet Valve 3 Appliance Water Inlet 4 Waste Water Outlet 5 RO Water Outlet Clean Water 6 24 V Input 7 Waste Water...

Страница 12: ...0 mm diameter bore bit Bore bit is attached to the end of the drill and it is set to low speed Water is poured on the ground to be drilled do not drill without water Bend the bore bit as 45 degrees an...

Страница 13: ...1 ME and 101 MD models only If waste water pipe of the sink is not a throat hose but a 40 mm plastic pipe it is mounted in a 3 8 clamp sealing sponge a xed state Figure 7a The ush is drilled from the...

Страница 14: ...r 101 ME model After the lter replacement process is nished the ball valve is opened respectively When water starts to come from the faucet tank valve opens and the faucet is closed Warning Performanc...

Страница 15: ...for 101ME model Tagesvolumen Daily Capacity 75 15gpd 284 47 L day Leistungsrate E ciency Rate 30 93 R ckgewinnungsrate Recycling Rate Arbeitsdruck Operating Pressure min max Arbeitstemp i Operating T...

Страница 16: ...l Valve 1 4 24 351011Z Front Cover 9 351022Z Upper Body Panel 25 356004Z Solenoid Valve 10 351005Z Digital Display Cover 26 346002Z High Pressure Switch 11 356001Z Digital Display 27 346001Z Low Press...

Страница 17: ...he appliance eliminate bendings if any Please consult the service Please consult the service This is not a fault Decrease in clean water is normal during winter Please consult the service Insu cient a...

Страница 18: ...e of GAC lter in gallon As water passes through the appliance the value decreases Figure 11d 3 MODE Shows the life of the 1 micron sediment lter in gallon As water passes through the appliance the val...

Страница 19: ...19...

Страница 20: ...Value SERVICE TELEPHONE PRODUCTSERIALNO Signature Service Personnel Name Surname TDSAfter Filter Replacement TDSBefore Filter Replacement REPLACEDFILTERS Order No FilterReplacement DatePRODUCT SERIALN...

Страница 21: ...WaterTUSValue SERVICE TELEPHONE PRODUCTSERIALNO Signature Service Personnel Name Surname TDSAfter Filter Replacement TDSBefore Filter Replacement REPLACEDFILTERS Order No FilterReplacement DatePRODUCT...

Страница 22: ...or the adapter of the appliance 11 Have you checked the chlorine in the membrane inlet after installation 12 Have you checked clean water waste water ratio 13 Have you selected the throttle based on t...

Страница 23: ...transmitted to the collection points for recycling the electrical and electronic appliances If you dispose of this product correctly you will be contributing to the protection of the nature and human...

Страница 24: ...Sitesi 7 Cad No 14 Beylikd z stanbul Tel 0212 875 35 62 Faks 0212 875 36 64 www iea com tr info iea com tr TDF 583 358015ZEN FOR INFORMATION AND SUPPORT SERVICES Name of the Distributor Company Telep...