Aura Cebilon Скачать руководство пользователя страница 17

17

Troubleshooting

Figure 10 c

Figure 10 d

**   Only applies to 101 ME and 101 MD models.

* This table only applies to 101ME model.

Foam in water or

milky coloured

water.

Low water from the

appliance.

No water is received

from the faucet despite

the tank is full.

There is noise in the

appliance.

The pump is running

continuously.**

Air in the system.

Pump is not operating and there is

no sufficient pressure.**

There is bending, crushing on the

hoses.

Pre-filter group is clogged.

Membrane does not perform well.

Inlet water temperature dropped.

Check valve is defective.

Tank storage air pressure is

insufficient.

Regulator

Waste water hose may

make noise.

This may occur due to clogging and

bending of the waste water hose.
High Pressure Switch may be

defective.**

Low Pressure Switch may be defective.**
Check valve may be defective.

Shut off valve may be defective.

Pump may be defective.

Air in the system is a normal occurrence after

initial installation. Sometimes, air caused by

the mains may exist. This will return to

normal after usage for a while. There is no

inconveniency for using this water.

Check whether the pump adaptor is

plugged in. If adaptor is plugged in, consult

to your service.**

Check all the hoses connected to the

appliance, eliminate bendings, if any.

Please consult the service.

Please consult the service.
This is not a fault. Decrease in clean

water is normal during winter.

Please consult the service.

Insufficient air in the tank. Please

consult the service.

Clean the clogging of the drain hose or

straighten the bended hose.

Close the inlet water and consult to your

service.
Close the inlet water and consult to your service.

Please consult the service.

PROBLEM

POSSIBLE CAUSES

RECOMMENDED SOLUTION

EO is shown on the

display and the

appliance does not

provide water. 

(Figure10a)

There is no mains water.

Filter life is completed.

E1 will be shown on the

display (Figure 10b).

Close the ball valve since there is no clean

water supplied to the mains after water is cut.

When the water returns, open the ball valve

after the mains water starts to flow clean.

Your appliance will be ready to use.

Please consult the service.

Water leakage is detected.

E2 will be shown on the

display (Figure 10c).

Please consult the service. Close the ball

valve and cut the water inlet.

It indicates that the filter life is nearly 

completed.

Please consult the service.

         icon is shown on the
display (Figure 10d).

If regulator setting pressure is equal to the mains 

water, this may make noise. The noise will stop 

when mains pressure is back to normal.
Make the position of the clamp attached to the 

flush and the waste water hose passing through 

it proper.

Содержание Cebilon

Страница 1: ...101ME Tested and Certified by NSF International NSF ANSI Standard 58 for the Reduction Claims Specified on the Performans Data Sheet DIGITAL WITH PUMP WITH OUT PUMP User Manual...

Страница 2: ...lease read the entire user manual carefully and keep it as a reference Dear Customer Our manual contains information about the technical and hardware features of three di erent models The appliance yo...

Страница 3: ...E FAUCET REVERSE OSMOSIS RO WATER PURIFICATION SYSTEMS WASTE WATER CONNECTION PRE TESTS POINTS FOR ATTENTION MAINTENANCE FILTER REPLACEMENT PERFORMANCE DATA SHEET FILTER REPLACEMENT PERIODS CEBILON PA...

Страница 4: ...trations while the water molecules pass through the pores the solid particles with a large size cannot pass Since there are more water molecules in the water with low concentration and as a result mor...

Страница 5: ...rane pre ltration processes such as sediment lter carbon lter are carried out to retain the coarse residues and the chlorine used in the water disinfection Components such as these lters used before a...

Страница 6: ...6 8 6 Parts and Functions Figure 2 RO System Diagram Abwasser Waste Water A Cable Connection Colours White Adapter B Red Solenoid Valve C Green Pump D Yellow Low Pressure Switch E Blue High Pressure S...

Страница 7: ...the water clear Automatic Shut o Valve controls the ow of water If the system continues to run after the tank is full the water is wasted as a waste This is an undesirable condition Water should be cu...

Страница 8: ...the waste water is drained Clean Water Faucet is where clean water is taken Pump Adapter is the power supply of the pump it converts the mains voltage to 24 V DC Fields of Use Solenoid Valve controls...

Страница 9: ...ce s tank capacity is 8 litres approximately 2 2 gallons BOX SIZE mm 580x277x450 8 L 100 psi 689 kPa TANK CAPACITY 6 7 psi 40 48 kPa AIR TANK PRESSURE 75 15 gpd 284 47 L day DAILY CAPACITY 85 98 PURIF...

Страница 10: ...form protective membrane solution Install the tube that has flow restrictor on it but not to install the tube that goes to post carbon filter Allow water flow for 2 3 minutes to clear the membrane sol...

Страница 11: ...sser Waste Water 11 8 2 7 6 3 4 5 1 Figure 4 RO Installation Diagram 1 Cebilon 2 Water Inlet Valve 3 Appliance Water Inlet 4 Waste Water Outlet 5 RO Water Outlet Clean Water 6 24 V Input 7 Waste Water...

Страница 12: ...0 mm diameter bore bit Bore bit is attached to the end of the drill and it is set to low speed Water is poured on the ground to be drilled do not drill without water Bend the bore bit as 45 degrees an...

Страница 13: ...1 ME and 101 MD models only If waste water pipe of the sink is not a throat hose but a 40 mm plastic pipe it is mounted in a 3 8 clamp sealing sponge a xed state Figure 7a The ush is drilled from the...

Страница 14: ...r 101 ME model After the lter replacement process is nished the ball valve is opened respectively When water starts to come from the faucet tank valve opens and the faucet is closed Warning Performanc...

Страница 15: ...for 101ME model Tagesvolumen Daily Capacity 75 15gpd 284 47 L day Leistungsrate E ciency Rate 30 93 R ckgewinnungsrate Recycling Rate Arbeitsdruck Operating Pressure min max Arbeitstemp i Operating T...

Страница 16: ...l Valve 1 4 24 351011Z Front Cover 9 351022Z Upper Body Panel 25 356004Z Solenoid Valve 10 351005Z Digital Display Cover 26 346002Z High Pressure Switch 11 356001Z Digital Display 27 346001Z Low Press...

Страница 17: ...he appliance eliminate bendings if any Please consult the service Please consult the service This is not a fault Decrease in clean water is normal during winter Please consult the service Insu cient a...

Страница 18: ...e of GAC lter in gallon As water passes through the appliance the value decreases Figure 11d 3 MODE Shows the life of the 1 micron sediment lter in gallon As water passes through the appliance the val...

Страница 19: ...19...

Страница 20: ...Value SERVICE TELEPHONE PRODUCTSERIALNO Signature Service Personnel Name Surname TDSAfter Filter Replacement TDSBefore Filter Replacement REPLACEDFILTERS Order No FilterReplacement DatePRODUCT SERIALN...

Страница 21: ...WaterTUSValue SERVICE TELEPHONE PRODUCTSERIALNO Signature Service Personnel Name Surname TDSAfter Filter Replacement TDSBefore Filter Replacement REPLACEDFILTERS Order No FilterReplacement DatePRODUCT...

Страница 22: ...or the adapter of the appliance 11 Have you checked the chlorine in the membrane inlet after installation 12 Have you checked clean water waste water ratio 13 Have you selected the throttle based on t...

Страница 23: ...transmitted to the collection points for recycling the electrical and electronic appliances If you dispose of this product correctly you will be contributing to the protection of the nature and human...

Страница 24: ...Sitesi 7 Cad No 14 Beylikd z stanbul Tel 0212 875 35 62 Faks 0212 875 36 64 www iea com tr info iea com tr TDF 583 358015ZEN FOR INFORMATION AND SUPPORT SERVICES Name of the Distributor Company Telep...

Отзывы: