background image

4

 

 

Clean water tank capacity  

2.2 gallons (approx. 8 liters)  

Clean water tank air pressure  

0.40  - 0.48 bar (40  - 40 kPa, 6  - 7 psi)  

 

Daily production  

34.03 gpd (128.6 l/d)  

Inlet of total dissolved solids 

(TDS)  

Max. 1250  ppm 

Waste water rate  

85  - 98 %  

Pressure pump flow rate*  

0.8  - 1.2 l/m  

Pump pressure  

0.8  - 1.10 bar (551  - 758 kPa,   

80  - 110 psi)  

 

Pump power supply*  

Input: 220  - 240 VAC / 50/60 Hz; 

output: 24 VDC / 0.8 (nom.) max. 

 

1.2 A  

System dimensions (mm)  

270 x  400 x 385  

Total weight  

With pump: 12.5 kg /   

without pump: 9.5 kg  

 

* Available for the model with pressure pump  

 

 

Do not use water for this system that is microbiologically unsafe, that has 

not been sufficiently disinfected before or after operation or that is of 

unknown quality.

 

Cebilon Platinum reverse osmosis system contains components 

that need to be replaced regularly in order to efficiently filter the dissolved 

solids (TDS) from the water. To check the efficiency of the system, check 

the water in the system regularly.

 

Therefore, please also replace regularly the components that need to be 

replaced. 

To ensure continuous efficiency and performance of the 

system, only use components that meet the defined specifications for 

replacement.

 

TECHNICAL SPECIFICATIONS

 

Содержание Cebilon Platinum

Страница 1: ...REVERSE OSMOSIS SYSTEM Cebilon Platinum with pump Operating and maintenance instructions Before installing and using the system please read these instructions carefully EN...

Страница 2: ...rine Clean water Waste water 2 Water leakage system 1 Regulator 3 Low pressure switch 4 5 m sediment filter 5 Pressure pump 6 Activated carbon granulate filter 7 1 m sediment filter 8 4 way shut off v...

Страница 3: ...he 1 m sediment filter removes the rest of the particles to ensure the correct functioning of the membrane The membrane is where the phenomenon of reverse osmosis occurs This component consists of a p...

Страница 4: ...pump when the water supply is turned off or the pressure is less than 0 2 bar 3 psi The pressure pump increases the pressure on the water flowing through the 5 m sediment filter to the value required...

Страница 5: ...le for the model with pressure pump Do not use water for this system that is microbiologically unsafe that has not been sufficiently disinfected before or after operation or that is of unknown quality...

Страница 6: ...s the function of a pH regulator and then to the clean water tank To ensure reliable functioning and a long service life of the membrane the amount of waste water must always be bigger than the amount...

Страница 7: ...ly system it must be subjected to a drinking water analysis by the responsible institutions 5 If the water used is not tap water make sure that the water is properly disinfected The ters are considere...

Страница 8: ...e adapter by wrapping it with Teflon tape in a position that allows easy opening and closing of the ball valve Fig 5 a Then connect the water supply hose to the ball valve Fig 5 b Make sure that the b...

Страница 9: ...s a risk that you will carry out the drilling incorrectly The tube should be carefully installed between the tap and the clean water outlet of the system Water connection fittings 1 Tap tube 2 Upper t...

Страница 10: ...ect the adapter to the power supply Open the tap for the clean water Close the clean water tank valve By opening the 1 4 ball valve the tap water is supplied to the system Fig 8 The pump starts workin...

Страница 11: ...house we recommend that you close the water inlet valve for safety reasons Fig 8 Repairs have to be carried out by qualified personnel The maintenance of your system should only be carried out by an...

Страница 12: ...vice life depends on the quality of the inflowing water Activated carbon granulate filter GAC 6 12 months This filter removes the chlorine from the water Excess chlorine reduces the service life of th...

Страница 13: ...r the dissolved solids TDS from the water To check the efficiency of the system check the water in the system regularly Please also replace the filters according to the specified replacement intervals...

Страница 14: ...tact a technician The system generates excessive noise A water flow noise can be generated in the waste water tube Correctly align the clamp attached to the siphon and to the outlet pipe This may be d...

Страница 15: ......

Страница 16: ......

Отзывы: