35
RWA Control Unit
LSF 7000
Installation of the relay card REL and BUS connection to the Control Unit
LSF 7000
i
nStaLLation
S
tep
3:
i
nstallation
of
the
r
elay
C
arD
rel
anD
bus C
onneCtion
20 a
10 a
5 a
2,5 a
i
nStaLLation
S
tep
3:
i
nstAllAtion
of
the
relAy
cArd
rel
And
bus
connection
1
1
1
5
71
72
1
2
3
1
2
3
BU
S-
M
od
ul
US
B
12
34
(F1)
(1/2 = Notstromversorgt)
7xPSB
24 V DC
(F2)
+ - + -
The function of the relay cards is factory-set: :
1. REL 65 = alarm activation / EMERGENCY OPEN
2. REL 65 = collective fault
Modification to these settings is only possible after the
system software has been activated by licence. Likewise,
the network integration requires activation which is sub-
ject to a licence fee.
Installation and Replacement of the relay / bus cards:
The following steps must be followed:
1.
First disconnect the Control Unit from the mains and battery power.
2.
Carefully insert the plug-in card in the correct direction.
3.
When correctly inserted, reconnect the power supply.
USB
Connect the device while it is voltage free! Switch off
the power supply and secure it against being switched
on again!
!
The motherboard has two slots for the use of one
REL 65
(Part.-No.:
650200
) each, so that messages can
be externally transmitted via a potential-free contact (1
x change-over switches, max. 42 V, 0.5 A).
The cables must be laid in accordance with the current
legal regulations. The terminal cross-section must be at
least 0.5 mm² (max. 1,5 mm²). The cable length is max.
400m.
1. REL 65
1. REL 65
terminal
terminal
side
side
Plug for front button
BUS
BUS
Length: max. 500 m (without repeater)
2-wire Twisted-Pair-Free-Topology BUS
(twisted copper cable)
Reset
2. REL 65
Remove the BUS plug
for connection!
License software is required for:
• unctionality of the 1st and 2nd REL 65
different from the standard configuration
• Networkk connection
Factory default setting
(can only be changed via licence software)
1. REL 65
alarm activation / EMERGENCY OPEN
2. REL 65
collective fault (inverted)
COM
COM
Contact Switching Capacity:
max. 42 V, 0,5 A
terminala 1,5 mm
2
2. REL 65
Plug-in card: 7xPSB
Part.-No.:
683256
Application:
plug-in card for
LSF 7000
for tapping the 24 V DC supply
voltage for external consumers.
Connection terminals: 4x 1,5 mm² (rigid wire)
Voltage tapping-off: 2 terminals 24 V DC
emergency power supply
2 terminals 24 V DC mains voltage
05
(1/2 = Emergency Power Supply)
Содержание Lift-Smoke-Free LSF 7000