5.
Place coupling [1] onto valve shaft [2] and secure against axial slipping by using
a grub screw [3] or a clamping washer. Thereby, ensure that dimensions X, Y
or L are observed (refer to figure and table <Mounting positions for coupling>).
Figure 11: Example: Fit coupling
[1]
Coupling
[2]
Valve shaft
[3]
Grub screw
Figure 12: Mounting positions for coupling
Table 4:
GS 500
GS 400
GS 315
Dimensions [mm]
F60
(F60/AUMA)
F60
1)
F48
F48
1)
F40
EN ISO 5211
40
36
26
X max.
0
0
0
Y max.
375
285
280
L max.
Coupling dimensions not according to EN ISO 5211 specifications
1)
18
GS 315 – GS 500
Assembly