![AUMA ACE C 01.2 Profinet Series Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/auma/ace-c-01-2-profinet-series/ace-c-01-2-profinet-series_manual_3016379058.webp)
Figure 69: Function check
For further information, please also refer to <Corrective action>.
Maintenance required (S0010)
The
S0010
indication shows maintenance indications according to NAMUR
recommendation NE 107.
If such an indication has occurred, the display shows
S0010
:
●
the number of indications occurred
●
a blinking square with an oilcan after approx. 3 seconds
Figure 70: Maintenance required
For further information, please also refer to <Corrective action>.
Failure (S0011)
The
S0011
indication shows the causes of the failure indication according to NAMUR
recommendation NE 107.
If such an indication has occurred, the display shows
S0011
:
●
the number of indications occurred
●
a blinking circle with a cross after approx. 3 seconds
Figure 71: Failure
For further information, please also refer to <Corrective action>.
58
SAEx 07.2 – SAEx 16.2/SAREx 07.2 – SAREx 16.2 Control unit: electronic (MWG)
Indications
ACExC 01.2 Non-Intrusive HART