AUKS Light CAC R22 60Hz T3 Controller
37
Remote conntroller:H series
LCD display instruction
1.Key Description
POWER button
: Switch the unit ON/OFF.
MODE button
: Select mode , push the button one time, then the operation modes will change in turn as
Auto-Cooling-Dehumidify-Heating
TEMP + button
and
TEMP - button
: Temperature adjustment range: 16~32,
Timing adjustment range: (0.5-24)h.
FAN button
: Change the fan speed will change in turn as: Low-Medium-High-Auto
SWING button
: Press this button for the first time when operation, it will start the swing function. Push the
button for the second time, cancel the swing function. (The function is available matched with the
concerned unit)
TIMER button
:Press the button to set TIMER ON/OFF.
SLEEP button
:
Press the button to the sleeping indicator light of indoor unit flashes on; the air conditioner will be
automatically turned into low speed operation with no changes on the display of remote control, and the
sleeping function will be activated.
1. After the setting of sleeping mode,the cooling operation enables the set temperature to increase 1
℃
after 1 hour and another 1
℃
auto matically after 1hour.
2. After the setting of sleeping mode,the heating operation enables the set temperature to drop 2
℃
after
1 hour and another 2
℃
auto matically after 1hour.
3. The air condition runs in sleeping mode for 7hours and stops automatically.
Remark:
Press the mode or ON/OFF button,the remote controller clears sleeping mode away.
“I-FEELING” button
1.Pressing this button, “ ” will displayed on the screen of the remote control, the temperature sensing
NOTE
:
ON/OFF display:
when the remote controller is on the
state, the LCD will be display or not.
Digital display:
Under the state of normal
working, it
displays setting temperature. While the
feeling function is start, it will display
room temperature, and under the state of
timer mode, it will display setting timer.
NOTE:Fan speed operation
When the air volume is greater, the noise
will be higher, The wind temperature will
rise when cooling mode,and drop when
heating mode;
Please selecte the appropriate F speed,
in order to achieve the more comfortable
rest environment
.
Содержание AFC-1000CF/4
Страница 1: ...1 Technical Manual Fan Coil Unit Ceiling Floor Type...
Страница 3: ...AUKS Fan CoilGeneral description 3 Part 1 General description 1 Nomenclature...
Страница 14: ...AUKS Fan CoilUnit information 14 4 Demension AFC 400CF 4 AFC 500CF 4 AFC 600CF 4 AFC 800CF 4 AFC 1000CF 4...
Страница 15: ...AUKS Fan CoilUnit information 15 5 Electrical wiring and connection...
Страница 22: ...AUKS Fan CoilUnit information 22 7 Explode view AFC 400CF 4 AFC 500CF 4...
Страница 30: ...AUKS Fan CoilUnit information 30...
Страница 53: ...Service Manual 53 6 Failure analysis Wired controller communication failure...
Страница 54: ...Service Manual 54 Drainage system failure...
Страница 55: ...Service Manual 55 No action after power on...
Страница 56: ...Service Manual 56 Poor Performance during Unit Operation...
Страница 57: ...Service Manual 57...
Страница 58: ...Service Manual 58 Abnormal sound or vibration...
Страница 59: ...Service Manual 59 Abnormal odor...
Страница 60: ...Service Manual 60 Air conditioner water leakage...