COMpact 5200/5200R/5500R - Firmware V7.2 - Advanced Information V04 07/2018
739
Settings – Périphériques
Interphones
Link to the page
Périphériques > Relais (actionneurs)
Deletes the relay or opens the configuration of the relay.
Appels d’interphone
Requirements:
•
Switch input (optional, see Technical Data in the Instructions)
•
Created door terminal
The door bell buttons of a door terminal can be used to initiate configuration-
dependent internal and external door calls. For this purpose, the door bell
buttons must be created as switch inputs in the PBX. They must then be
allocated call destinations and assigned to the door terminal. To detect a
door call, e. g. because a door bell button has been pressed, the PBX needs
to know which DTMF sequence or which SIP invite the connected device
sends in this case (see manual and settings of the device in question).
Note:
The DTMF sequence or the SIP invite usually is the phone
number assigned to the door bell button within the door terminal. After
the door terminal has been configured in the configuration of the PBX,
the door call distribution will be controlled completely – including config-
uration-dependently – by the PBX.