4.1.2- Positioning and anchoring
• To ensure the proper functioning of the heat pump water heater
and to facilitate maintenance work, a space must be left free
around the appliance, as well as a minimum ceiling height so
that the hood can be removed.
• It is PROHIBITED to install the appliance:
- Outside.
- In rooms exposed to frost, where the temperature is less than
7°C, including when the appliance is operating.
- In humid rooms which have significant steam or vapour
emissions (for example, a bathroom).
- In rooms where there is any risk of explosion due to gas,
pollution or dust.
•
Avoid placing the appliance close to bedrooms to minimise
noise pollution.
•
Do not install the air intake nozzle near a vapour exhaust
(minimum distance of 0,6m).
3.2 - Technical specifications and
performances
4.1- Placement and positioning
• It is PROHIBITED :
- To let the appliance operate using air intake which contains
solvents or explosive materials.
- To use air intake which contains grease, dust or aerosol particles.
- To connect vented exhaust hoods to the ventilation system.
-To use air intake containing combustion materials from a boiler.
4 - INSTALLATION
INSTALLATION PRECAUTIONS :
• The appliance must not be installed near a
perpetual flame or other source of ignition.
• The appliance must be installed in such a way so
as to avoid mechanical damage to the appliance.
4.1.1- Placement choice
Heat pump performance
Nominal volume
L
200
270
Max. input power
W
1900
1900
Air temperature range
O
C
-7 to +35
-7 to +35
DHW* temperature with heat
pump
O
C
30 to 60
30 to 60
Max. heat pump power
consumption
W
700
700
Air flow rate
m
3
/h
320 to 400
320 to 400
Sound pressure level at 1m**
dB(A)
37/40
37/40
Refrigerant
-/kg
R290 /0.15
R290 /0.15
Global warming potential
kg
0.45kg CO
2
equivalent
0.45kg CO
2
equivalent
Type of air connection
-
Exterior or
ambient air
Exterior or
ambient air
Normative Data (EN 16147)
Draw cycle
-
L
L
COP* (outdoor air +7
o
C)
-
3.19
3.14
Reserve capacity
W
23
25
Hot water reference
temperature
O
C
54.2
55.8
Heating time
-
7H04
10H15
Energy class
-
A+
A+
Seasonal energy efficiency
%
132
130
Vmax
L
247.4
349.3
V40 td
L
614
650.4
COP* (ambient air +15
o
C)
-
3.37
3.47
Dimensions and connections
Dimensions
mm
Ø630 x H 1460 Ø630 x H 1780
Weight when empty
kg
56.5
63
Air connection diameter
(intake / exhaust)
mm
160
160
Max. length for air ducts
m
Flexible tube: 6m
Rigid pipe: 12m
( exhaust)
Connection diameter for
DCW* and DHW*
inches
M 3/4"
M 3/4"
Electrical power supply
V-Hz-A 230V-50Hz-8A 230V-50Hz-8A
Protection rating
-
IPX4
IPX4
D-curve circuit breaker
A
8
8
Tank
Materials / protection
-
Stainless
steel
Stainless
steel
Maximum service pressure
MPa
0.6 (6 bars)
0.6 (6 bars)
Max. condensates flow rate
L/h
0.3
0.3
Built-in electrical back-up
power (85
-
C safety setting)
W
1200
1200
Max. temp with electrical
back-up
C
O
65
65
-
installer
HEAT PUMP WATER HEATER 200 -270L AIR D/2 -
manual
-
-
installer
HEAT PUMP WATER HEATER 200 -270L AIR D/2 -
manual
-
6
EDEL AIR
200L D/2
EDEL AIR
270L D/2