6.4 - Troubleshooting
• The heat pump is not working
Check that:
• The desired water temperature is higher than the temperature
of the water in the tank.
• The appliance is connected to a power supply.
• The green light is on.
• The appliance is not in holiday mode (symbol
).
• The air intake or ambient temperature is under -7°C or over
+35°C (ELEC MODE displayed).
• The timer has not been programmed to stop the appliance
operating ( «economy» light will be on).
•The appliance is not in load shedding mode.
• An error message is displayed on the screen (see § Error
message codes).
Do not adjust settings
on safety aquastat
• Condensates are not draining
(water present under the appliance)
Check that:
• The drainage system is not blocked:
- Remove the cover (see § «External control» procedure).
- Check the opening.
• The tubes do not have bends or ‘‘U’’ shapes that could collect
water.
• The end of the tube gives out onto open air.
•The tank is properly positioned (vertical position and no
tilting).
• Electrical back-up is not working
Check that:
• Your electricity provider or your timer is not preventing the
appliance from functioning ( «Economy» light on).
• A heat-limiting safety thermostat for electrical back-up has
not been activated after over-heating (>85°C). If this is the
case, reset it.
Before resetting, check:
- That the heating element does not have limescale.
- Clean or replace if necessary.
6.6 - Sensor data
0
5
10
15
20
25
30
35
40
45
50
55
60
-10
-5
0
5
10
15
20
25
30
35
40
Température (°C)
Résistance
(kOhms)
All 4 sensors have the same ohmic values.
Reset button
(85°C) on safety
aquastat
• No hot water
Check that:
• The volume of water consumed is not higher than the volume
in the tank.
• The time period that the appliance operates is not too short
(12h minimum if connected to piping).
• The water temperature is not set too low.
• There is no recirculation pump.
6.5 - Drainage
1) Switch off the power supply.
2) Shut off the cold water inlet valve on the safety group.
3) Open the hot water valves.
4) Set the safety group to the drainage position.
-