background image

Neglecting to clean the circuit board 

and other electronic components in a 

dusty environment can lead to a risk of 

overheating and ignition.

6 - MAINTENANCE AND 

TROUBLESHOOTING

In order to maintain efficiency and improve durability 

it is advised that an annual maintenance check be 

carried out by a qualified professional.

• Any work on the heat pump must be 

carried out by a qualified professional. 

• Observe all health and safety rules !

• Any work on the refrigerant circuit must be 

carried out by a qualified professional  with a 

Category 1 certificate of aptitude. 

• It is strictly prohibited to release refrigerant gas 

into the atmosphere. 

  The refrigerant must be collected before any 

work is carried out on the circuit.

• Switch off the heat pump water heater before 

opening it. 

• Wait for the fan to come to a complete stop 

before starting work on the appliance. 

•Do not get water on any of the electrical parts. 

• The pressure limiting device must be operated 

regularly to eliminate limescale and to check 

for blockages. 

• Check the condition of the corrosion-proof 

anode at minimum once per year. 

6.1 - Water circuit / Condensate 

draining

To check that the condensates are draining correctly:

- Remove the upper cover (see § «Electrical connections» 

procedure).

- Check for blockages in the drainage outlet.

- Clean the condensate recovery trough, where deposits 

from the air intake may have gathered.

- Clean the flexible drainage hose.

The pressure limiting device must be switched on regularly to 

eliminate limescale and to check for blockages.
Check that all hydraulic connections on the 

heat pump water 

heater

 are watertight.

When draining the tank, ensure that there is a large enough air 

inlet at the top to avoid any depression in the tank. The following 

materials and products should be avoided:
 

- Brushes with steel bristles or pads

 

- Scouring powder

 

- Any bleach-based product or chlorinated derivative

In case of maintenance or if taking the 

heat pump water 

heater

 out of service, please respect the environmental 

protection regulations regarding recovery, recycling and disposal 

of consumables and components. 

The only maintenance work needed on the air intake circuit is to 

clean the evaporator (at least once per year and dependent on 

the quality of air intake).
If using air filters check if they are clean regularly. Clean and 

replace if necessary.

The fan blades are sharp-edged and may cause injury; take care 
not to damage or deform them.

6.2 - Air intake circuit

It is mandatory to periodically inspect for the cleanliness and the 

absence of dust deposits on the electronic circuit board and the 

electrical terminals:

 

• of the compressor;

 

• of the electrical resistance ;

 

• of the different condensers.

Verify the correct tightness of all lugs. Adapt the frequency 

of inspection to the air quality. In a dusty environment more 

frequent maintenance and inspection is necessary, at minimum 1 

time per year. 

6.3 - Electrical maintenance

.../...

 The refrigerant circuit containing 

flammable refrigerant complies with national 

gas regulations.

 In case of operating on the refrigerant circuit:

  1) Secure the area you will be working in

  2) Inform people of the potential danger 

involved in the work

  3) Check that the risk of inflammation is 

minimised

  4) Avoid working in a confined space; the area 

must be sufficiently ventilated

  5) Check the area with an appropriate leak 

detector before and during the work

  6) Place a CO

2

 dry powder extinguisher near 

the work area

The R290 refrigerant in the heat pump 

circuit poses no risk to the environment, 

but it is flammable.

 The R290 refrigerant is odourless.

 Do not damage the pipes in the refrigerant 

circuit. 

 Do not handle a flame or any other flammable 

source on the inside of the appliance. 

 If the refrigerant is leaking, unplug the 

appliance, air out the room, and contact 

customer service.

 Do not use any mechanical means to speed 

up the defrosting process.

Do not pierce or burn the appliance: in case 

of intervention on the refrigerant circuit, the 

refrigerant must be recovered.

.../...

installer

 

HEAT PUMP WATER HEATER 200 -270L AIR D/2 -

 

manual

 - 

installer

 

HEAT PUMP WATER HEATER 200 -270L AIR D/2 -

 

manual

16

Содержание 353420

Страница 1: ...rior or non heated ambient air The information contained in this document is non contractual Auer reserves the right to modify the technical specifications or characteristics of any of their appliances without prior notice Edel 200 AIR D 2 Ref 353420 Edel 270 AIR D 2 Ref 353430 Necessary technical data in appendix ...

Страница 2: ...e electrical back up 12 5 8 Programming 12 5 6 BOOST function for occasional use and guaranteed comfort 12 5 9 Installer menu 13 5 9 1 PV mode 13 5 9 2 Adjusting the operating settings 13 5 9 2 1 ANTI BACT anti legionellosis cycle 13 5 9 2 2 fan mode 14 5 9 2 3 T C MINI Minimum temperature 14 5 9 2 4 Load shedding Level authorised during peak hours 14 5 9 2 5 max time Max heating time 14 5 9 3 Loc...

Страница 3: ...14 35 UE directive concerninglowvoltage andthe2013 814 UE concerning eco design 1 SAFETY Danger of death by electrocution Touchingliveelectricalwirescancausesevere injury Before undertaking any work on the appliance ensure to switch off the power supply to the appliance Ensure that there is no possibility of the power supply becoming active again Danger of injury or death due to the absence of or ...

Страница 4: ...alified professional to avoid risk of injury See the Dimensions page 5 and the Installation page6 ofthismanualtofindthe necessarydimensionsforproperinstallationof this appliance See the Hydraulic connections page 7 of thismanualtofindtheminimumandmaximum water pressures and temperatures WARNING Do not use any methods to accelerate the defrosting or cleaning process other than those recommended by ...

Страница 5: ...andling precautions Keepthetransportbagoutofthereachof children riskofsuffocation Iftipped thecentreofgravitywillshift towardsthetop handlewithcare Remove plastic cover and cardboard packaging Remove corner protection pieces ensuring that all nails and staples are taken out and disposed of Remove protective film from all parts of the appliance and from the bag of accessories which you will find in...

Страница 6: ... choice Heat pump performance Nominal volume L 200 270 Max input power W 1900 1900 Air temperature range O C 7 to 35 7 to 35 DHW temperature with heat pump O C 30 to 60 30 to 60 Max heat pump power consumption W 700 700 Air flow rate m3 h 320 to 400 320 to 400 Sound pressure level at 1m dB A 37 40 37 40 Refrigerant kg R290 0 15 R290 0 15 Global warming potential kg 0 45kg CO2 equivalent 0 45kg CO2...

Страница 7: ... Ref 730014 If over 1m long the pipes must be anchored to the wall using a collar Ref 730013 The stainless steel horizontal terminal Ref 730015 is equipped with a protective grill 4 2 3 Piping accessories 4 3 Hydraulic connections A new pressure relief valve not included must be installed and set to 6 bars on the domestic cold water supply of the appliance We would recommend a membrane valve The m...

Страница 8: ...ds in effect in the country of use notably hydraulic regulations and pressure safety regulations The appliance must operate with water between 12o F and 30o F With particularly hard water TH 25o F it is advised to use a water softener If any of these points have been neglected the warranty will be null and void values given are for water at a temperature of 20o C See DTU 60 1 for more information ...

Страница 9: ... Switch closed the fan will operate Set the regulator to External control ventilation mode fan mode 3 4 5 1 2 Controlled ventilation 4 5 1 1 Peak off peak hours contact To prevent the electrical back up from running during peak hours connect the dry contact originating from the electricity counter to terminal 1 Switch open Back up not allowed to run Switch closed Back up allowed to run By choosing...

Страница 10: ...ensure that the entire circuit is watertight The heat pump water heater operates primarily with the heat pump as long as the air intake temperature remains in the authorised range from 7 C à 35 C Outside of this range the electrical back up ensures the heating of domestic hot water The temperature of the domestic hot water provided by the heat pump is adjustable up to 60 C In the case of high dome...

Страница 11: ...too high unless necessary The default temperature is set at 55 C 5 4 1 PV mode inactive Set the month 26 09 11 17 32 09 11 17 32 26 11 17 32 Set the day 26 09 17 32 Set the year monday 32 Set the hour monday 17 Set the minutes Confirm new settings Press Turn the dial to scroll through menu options When PV mode is activated the water temperature can be set to a higher level to favour operation duri...

Страница 12: ...time during a heating cycle The electrical back up symbol flashes while it activated Press Turn the dial to scroll through the menu options The boost function is automatically deactivated as soon as the set temperature is reached end of heating cycle Press to return to the main menu boost yes 5 6 BOOST function for occasional use and guaranteed comfort Enter 5 8 Programming Programming enables you...

Страница 13: ...n modes No The eco and frost protection modes take precedence over the signals from connectors 1 and 2 N B If PV mode is chosen as the primary function the domestic hot water will also be heated during non selected time periods e g in holiday mode and outside of the programmed time slots If you only wish the domestic hot water to be heated during authorised time slots adjust the settings to No 8 P...

Страница 14: ...g time of the tank If you choose MAX time AUTO the heating time is limited to a maximum of 5h during off peak hours In case of load shedding the T C mini function is not activated Factory setting 1 Mode 1 Standard mode automatic ventilation Mode 2 Forced ventilation max speed Mode 3 Ventilation activated during water heating periods and ventilation regulated by an external control such as a moistu...

Страница 15: ...without gaining access through the Installer menu provided that locking settings are not already in place To lock manually press for 3 seconds Press for 3 sec locking pro To lock access to menus with temporary unlocking 300 seconds is possible by pressing for 3 seconds and then and buttons for 3 seconds Enter Select yes 500 C unlock no Press for 3 sec Enter Select yes 500 C unlock no unlock yes Pr...

Страница 16: ...ing the heat pump water heater out of service please respect the environmental protection regulations regarding recovery recycling and disposal of consumables and components The only maintenance work needed on the air intake circuit is to clean the evaporator at least once per year and dependent on the quality of air intake If using air filters check if they are clean regularly Clean and replace i...

Страница 17: ...al position and no tilting Electrical back up is not working Check that Your electricity provider or your timer is not preventing the appliance from functioning Economy light on A heat limiting safety thermostat for electrical back up has not been activated after over heating 85 C If this is the case reset it Before resetting check That the heating element does not have limescale Clean or replace ...

Страница 18: ...ly cable not visible B4993827 B4993827 AC cabling kit Electrical back up 11 B4992886 B4992886 1200W heating element gasket kit 12 B1657452 B1657452 Heating element seal 13 B1239160 B1239160 Aquastat Refrigerant circuit 14 B4993828 B4993828 Compressor kit 15 B1472970 B1472970 Finned heat exchanger 16 B1472871 B1472871 Drying filter 17 B1472917 B1472917 Thermostatic expansion valve 18 B1239261 B1239...

Страница 19: ...trol is connected to the external control switch over press Heat pump pressure too high No water in the tank Water is too hot 75 C Water sensor removed from tank Defective water sensor Check that the tank has been properly filled with water and purged of air Change the water sensor Check that the water sensor is in the right position in the tank Heat pump is non functional Must be manually reset f...

Страница 20: ...ture is activated Defect in compressor Replace the compressor ERR 02 Incorrect temperature sensor readings The air and water sensors are inverted on the electronics board The defrosting sensor is connected to the air input the air sensor is connected to the water input the water sensor is connected to the defrosting input Reposition the temperature sensors properly on the main electronics board Ap...

Страница 21: ...n 7 1 2 Exclusion from warranty 7 1 2 1 Use 7 1 2 3 Installation site Cases not limited to where the warranty is void Placing the appliance where it can be subject to frost or other adverse weather conditions Non compliance with the instructions in the manual when installing the appliance Installing the appliance on a surface which cannot bear its weight when filled with water Installing the appli...

Страница 22: ... hot water 8 1 Performance statistics 8 1 1 COP development Air temperature Heating time at 60o C Heating time at 45o C Heating time at 60o C Heating time at 45o C Air temperature Air temperature This graph represents the heating time for a full tank depending on the air and domestic hot water temperatures using the heat pump and without a back up 8 1 2 Heating time installer HEAT PUMP WATER HEATE...

Страница 23: ...8 2 Electrical wiring diagram installer HEAT PUMP WATER HEATER 200 270L AIR D 2 manual 23 ...

Страница 24: ...forecarryingoutanyworkon thecircuit Switchofftheheatpumpwaterheaterbeforeopeningit Waitforthefantocometoacompletestopbeforeundertakinganywork ontheappliance Industrial and development site Rue de la République CS 40029 80210 Feuquières en Vimeu Spare parts department Tél 03 22 61 21 21 Fax 03 22 61 33 35 E mail pieces auer fr Technical department E mail enr auer fr Technical assistance service is ...

Отзывы: