Technical data 

 

Type 

ultra low noise, highly stable and constant power 
supply for EPS/EPX compatible Audionet units 

Power supply 

two encapsulated 200 VA toroidal transformers and 
576.000 

µ

F capacitance 

Circuitry 

reference voltage sources for pos. and neg. analog 
voltages using discrete Audionet voltage regulators 
(MOS) 

Connections 

7-pin socket for connecting the mother unit 

Output voltage 

±24.00 V for analog sections, 

+5V for digital and control sections 

Stability 

±0.01 V at 3 A 

Noise 

-144 dB or 1.5 

µ

V

eff

 for 0 Hz up to 22 kHz 

Mains 

120 V or 230 V, 50 Hz .. 60 Hz 

Power consumption 

Standby < 0.5 W, max. 400 W 

Dimensions 

W: 

430 mm 

H: 

110 mm 

D: 

360 mm 

Weight 

18 kg 

Finish 

Front-panel

:  

aluminium, black anodized, light grey printing 
aluminium, nature anodized (silver), black printing 

LED:

 red or blue 

Top-cover

: aluminium, black anodized, 4 mm 

Side-plates

: aluminium, black anodized, 8 mm 

Chassis

: 2 mm sheet-steel, black varnished 

 

Errors and omissions excepted. Specifications and design are subject to changes without prior notice. 

 
 
 
 
 
 
 

audionet

 is a trademark of Idektron GmbH & Co KG 

 

Engineered and produced by:

 

Idektron GmbH & Co. KG, Herner Str. 299, Gebäude 6, 44809 Bochum, Germany 

www.audionet.de 

[email protected]

 

Содержание EPX

Страница 1: ...1 External Power Supply User s Manual ...

Страница 2: ...panel 5 4 Installation and connection 6 4 1 Placement 6 4 2 Mains connection 6 4 3 Connecting the mother unit 7 5 Usage 8 5 1 Powering up 8 5 2 Switching on off 8 5 3 Mains phase detection 9 6 Protection system 9 7 Technical Information 10 7 1 Features 10 8 Security advice 11 9 Technical data 12 ...

Страница 3: ...it In case of occurring ques tions please do not hesitate to contact your local Audionet dealer or our factory directly 1 1 Included Included you will find the following items The Enhanced Power Supply EPX The user s manual that you are currently reading One EPX connection cable One standard mains cord 1 2 Transport Important Please transport the EPX only in the included package Always use the pla...

Страница 4: ...4 2 Overview front panel LED power indicator ...

Страница 5: ...5 3 Overview back panel 1 Mains switch 2 Mains input 3 Marking mains phase 4 7 pin connector 1 4 3 2 ...

Страница 6: ...ke radiators Do not place the EPX on top of other units especially not on top of power amplifiers pre amplifiers or similar that produce heat Both units could suffer damage from thermal overload Do not use the unit in places where it is exposed to vibrations Do not place the unit close to loudspeakers or into the corner of a room where it is exposed to high levels of sonic energy which might reduc...

Страница 7: ...ch To disconnect the unit completely from mains pull the mains plug 4 3 Connecting the mother unit For the connection of the mother unit an EPX cord with 5 pin or 7 pin connector is needed An overview can be found in the following table EPX cord with 5 pin connector EPX cord with 7 pin connector Image of the connector Mother unit DNP DNA DNC PRE 1 G3 VIP VIP G2 VIP G3 ART ART V2 ART G2 ART G3 PRE ...

Страница 8: ...he mother unit to stand by mode and switch off the EPX on the back panel 5 2 Switching on off Please first turn on the mother device by its mains switch on the back panel Then operate the mains switch on the back panel of the EPX to set it to stand by mode The position of mains switch of mother devices that need no additional mains connection see section Connecting the mother unit on page 7 is neg...

Страница 9: ...f your mains socket and mains cord You have to ensure a stable connection to earth for the mains phase detection of the EPX to work correctly 6 Protection system Your Audionet EPX is equipped with a powerful protection system that safeguards the mother device and itself In case of an error the EPX will show this error state by a special LED flash code If the EPX LED flashes like this x _ x _ x _ x...

Страница 10: ...des 24 00 V The usage of accumulators is questionable regarding to environmental concerns Last not least you are able to listen to your music with high end quality using the EPX whenever you like not being forced to wait for accumula tors being charged 7 1 Features Discrete circuit layout for positive and negative voltage Two 200 VA toroid transformers Total capacitance per voltage 288 000 μF tota...

Страница 11: ...re and operate the unit in a dry room at a reasonable room tempera ture only Avoid moisture any liquids dirt or small objects getting into the unit Set up the unit in a sufficiently ventilated environment Do not cover the unit Do not open the unit Unauthorised opening will void warranty Use dry cloth for cleaning ...

Страница 12: ...dB or 1 5 µVeff for 0 Hz up to 22 kHz Mains 120 V or 230 V 50 Hz 60 Hz Power consumption Standby 0 5 W max 400 W Dimensions W 430 mm H 110 mm D 360 mm Weight 18 kg Finish Front panel aluminium black anodized light grey printing aluminium nature anodized silver black printing LED red or blue Top cover aluminium black anodized 4 mm Side plates aluminium black anodized 8 mm Chassis 2 mm sheet steel b...

Отзывы: