background image

 

Usage 

5.1  Powering up 

First  of  all,  please  make  sure  your  EPX  is  connected  correctly  to  the 
mother  unit  and  the  mains  (see  section 

'

Mains  connection

'

  on  page  6 

and 

'

Connecting the mother unit

'

 on page 7). 

The  EPX  is  a  stand  by  unit.  Please  operate  the  mains  switch 

 1 

  on  the 

back panel to put the EPX in stand by mode. 

Only in cases of extended absence (like vacations) or if massive trouble 
on  the  mains  power  is  to  be  expected  (e.g.  thunder  storms)  it  is  recom-
mended  to  disconnect  the  EPX  from  the  mains.  To  disconnect  the  EPX 
from  mains  completely,  you  have  to  pull  the  mains  cord  off  the  mains 
jack. 

 

 

Important

 

 

Never  pull  the  mains  cord  while  the  EPX  or  the  mother  unit  is 
switched on! Before you pull the mains plug, power down the mother 
unit to stand-by mode and switch off the EPX on the back panel. 

 

5.2  Switching on/off 

Please  first  turn  on  the  mother  device  by  its  mains  switch  on  the  back 
panel. Then operate the mains switch on the back panel of the EPX to set 
it to stand by mode. 

The  position  of  mains  switch  of  mother  devices  that  need  no  additional 
mains connection (see section 

'

Connecting the mother unit

on page 7) 

is negligible. 

Now operate the mother device as usual, all functions are the same. If the 
mother  device  is  switched  on,  the  LED  on  the  front  panel  of  the  EPX 
reports  the  polarization  of  mains  phase  for  a  few  seconds  (see  section 

'

Mains phase detection

'

 on page 9) before it keeps shining permanently. 

If you switch off the mother device, the power LED of the EPX turns off. 
 

 

Note 

 

For  further  information  on  starting  up  a  mother  device  with  5-pin 
connector in combination with an EPX please consult the user's man-
ual of the mother device. 

Содержание EPX

Страница 1: ...1 External Power Supply User s Manual ...

Страница 2: ...panel 5 4 Installation and connection 6 4 1 Placement 6 4 2 Mains connection 6 4 3 Connecting the mother unit 7 5 Usage 8 5 1 Powering up 8 5 2 Switching on off 8 5 3 Mains phase detection 9 6 Protection system 9 7 Technical Information 10 7 1 Features 10 8 Security advice 11 9 Technical data 12 ...

Страница 3: ...it In case of occurring ques tions please do not hesitate to contact your local Audionet dealer or our factory directly 1 1 Included Included you will find the following items The Enhanced Power Supply EPX The user s manual that you are currently reading One EPX connection cable One standard mains cord 1 2 Transport Important Please transport the EPX only in the included package Always use the pla...

Страница 4: ...4 2 Overview front panel LED power indicator ...

Страница 5: ...5 3 Overview back panel 1 Mains switch 2 Mains input 3 Marking mains phase 4 7 pin connector 1 4 3 2 ...

Страница 6: ...ke radiators Do not place the EPX on top of other units especially not on top of power amplifiers pre amplifiers or similar that produce heat Both units could suffer damage from thermal overload Do not use the unit in places where it is exposed to vibrations Do not place the unit close to loudspeakers or into the corner of a room where it is exposed to high levels of sonic energy which might reduc...

Страница 7: ...ch To disconnect the unit completely from mains pull the mains plug 4 3 Connecting the mother unit For the connection of the mother unit an EPX cord with 5 pin or 7 pin connector is needed An overview can be found in the following table EPX cord with 5 pin connector EPX cord with 7 pin connector Image of the connector Mother unit DNP DNA DNC PRE 1 G3 VIP VIP G2 VIP G3 ART ART V2 ART G2 ART G3 PRE ...

Страница 8: ...he mother unit to stand by mode and switch off the EPX on the back panel 5 2 Switching on off Please first turn on the mother device by its mains switch on the back panel Then operate the mains switch on the back panel of the EPX to set it to stand by mode The position of mains switch of mother devices that need no additional mains connection see section Connecting the mother unit on page 7 is neg...

Страница 9: ...f your mains socket and mains cord You have to ensure a stable connection to earth for the mains phase detection of the EPX to work correctly 6 Protection system Your Audionet EPX is equipped with a powerful protection system that safeguards the mother device and itself In case of an error the EPX will show this error state by a special LED flash code If the EPX LED flashes like this x _ x _ x _ x...

Страница 10: ...des 24 00 V The usage of accumulators is questionable regarding to environmental concerns Last not least you are able to listen to your music with high end quality using the EPX whenever you like not being forced to wait for accumula tors being charged 7 1 Features Discrete circuit layout for positive and negative voltage Two 200 VA toroid transformers Total capacitance per voltage 288 000 μF tota...

Страница 11: ...re and operate the unit in a dry room at a reasonable room tempera ture only Avoid moisture any liquids dirt or small objects getting into the unit Set up the unit in a sufficiently ventilated environment Do not cover the unit Do not open the unit Unauthorised opening will void warranty Use dry cloth for cleaning ...

Страница 12: ...dB or 1 5 µVeff for 0 Hz up to 22 kHz Mains 120 V or 230 V 50 Hz 60 Hz Power consumption Standby 0 5 W max 400 W Dimensions W 430 mm H 110 mm D 360 mm Weight 18 kg Finish Front panel aluminium black anodized light grey printing aluminium nature anodized silver black printing LED red or blue Top cover aluminium black anodized 4 mm Side plates aluminium black anodized 8 mm Chassis 2 mm sheet steel b...