background image

 

10 

Technical Information 

 

Your EPX provides the mother unit with ideal operating conditions. The 
popular usage of accumulators shows the following serious disadvantage:  

The  output  voltage  is  not  short  term  stable:  The  internal  impedance  is 
10

 

times worse than the one of your EPX causing an output ripple voltage 

10

 

times in magnitude at the same load condition. 

The output voltage is not long term stable: The output voltage of an ac-
cumulator is highly dependent from its state of charge and usage history, 
typically ranging from 23 V to 28

 

V. The EPX always provides 24.00

 

V. 

The  usage  of  accumulators  is  questionable  regarding  to  environmental 
concerns. 

Last not least you are able to listen to your music with high-end quality 
using the EPX whenever you like not being forced to wait for accumula-
tors being charged. 

7.1  Features 

 

 

Discrete circuit layout for positive and negative voltage 

 

Two 200

 

VA-toroid transformers 

 

Total capacitance per voltage: 288.000

 

μ

F (totally 576.000

 

μ

F) 

 

Custom made Audiograde Capacitors with silk dielectric 

 

Separate power supply for control and standby purposes 

 

High precision voltage regulators with discrete MOSFETs 

 

High precision and low noise reference voltage 

 

Short-circuit proof and protected against overheating 

 

Internal wiring with ultralow impedance silver/gold cables 

 

Mains phase detection 

Содержание EPX

Страница 1: ...1 External Power Supply User s Manual ...

Страница 2: ...panel 5 4 Installation and connection 6 4 1 Placement 6 4 2 Mains connection 6 4 3 Connecting the mother unit 7 5 Usage 8 5 1 Powering up 8 5 2 Switching on off 8 5 3 Mains phase detection 9 6 Protection system 9 7 Technical Information 10 7 1 Features 10 8 Security advice 11 9 Technical data 12 ...

Страница 3: ...it In case of occurring ques tions please do not hesitate to contact your local Audionet dealer or our factory directly 1 1 Included Included you will find the following items The Enhanced Power Supply EPX The user s manual that you are currently reading One EPX connection cable One standard mains cord 1 2 Transport Important Please transport the EPX only in the included package Always use the pla...

Страница 4: ...4 2 Overview front panel LED power indicator ...

Страница 5: ...5 3 Overview back panel 1 Mains switch 2 Mains input 3 Marking mains phase 4 7 pin connector 1 4 3 2 ...

Страница 6: ...ke radiators Do not place the EPX on top of other units especially not on top of power amplifiers pre amplifiers or similar that produce heat Both units could suffer damage from thermal overload Do not use the unit in places where it is exposed to vibrations Do not place the unit close to loudspeakers or into the corner of a room where it is exposed to high levels of sonic energy which might reduc...

Страница 7: ...ch To disconnect the unit completely from mains pull the mains plug 4 3 Connecting the mother unit For the connection of the mother unit an EPX cord with 5 pin or 7 pin connector is needed An overview can be found in the following table EPX cord with 5 pin connector EPX cord with 7 pin connector Image of the connector Mother unit DNP DNA DNC PRE 1 G3 VIP VIP G2 VIP G3 ART ART V2 ART G2 ART G3 PRE ...

Страница 8: ...he mother unit to stand by mode and switch off the EPX on the back panel 5 2 Switching on off Please first turn on the mother device by its mains switch on the back panel Then operate the mains switch on the back panel of the EPX to set it to stand by mode The position of mains switch of mother devices that need no additional mains connection see section Connecting the mother unit on page 7 is neg...

Страница 9: ...f your mains socket and mains cord You have to ensure a stable connection to earth for the mains phase detection of the EPX to work correctly 6 Protection system Your Audionet EPX is equipped with a powerful protection system that safeguards the mother device and itself In case of an error the EPX will show this error state by a special LED flash code If the EPX LED flashes like this x _ x _ x _ x...

Страница 10: ...des 24 00 V The usage of accumulators is questionable regarding to environmental concerns Last not least you are able to listen to your music with high end quality using the EPX whenever you like not being forced to wait for accumula tors being charged 7 1 Features Discrete circuit layout for positive and negative voltage Two 200 VA toroid transformers Total capacitance per voltage 288 000 μF tota...

Страница 11: ...re and operate the unit in a dry room at a reasonable room tempera ture only Avoid moisture any liquids dirt or small objects getting into the unit Set up the unit in a sufficiently ventilated environment Do not cover the unit Do not open the unit Unauthorised opening will void warranty Use dry cloth for cleaning ...

Страница 12: ...dB or 1 5 µVeff for 0 Hz up to 22 kHz Mains 120 V or 230 V 50 Hz 60 Hz Power consumption Standby 0 5 W max 400 W Dimensions W 430 mm H 110 mm D 360 mm Weight 18 kg Finish Front panel aluminium black anodized light grey printing aluminium nature anodized silver black printing LED red or blue Top cover aluminium black anodized 4 mm Side plates aluminium black anodized 8 mm Chassis 2 mm sheet steel b...