SIP Hardware Installation Manual
56
Document #: LTRT-94701
3000 Series Gateways & Media Servers
¾
To connect the GbE interfaces, take this step:
On the RTM-8410, connect the LAN cable to each of the GbE port connectors, using
Category 5 LAN cables with RJ-45 connectors (refer to the figure below):
Table
3-6: RJ-45 Connector Pinouts
Pin
FE Signal
GE Signal
1
TX DATA+1
Tx A+
2
TX DATA-
Tx A-
3
RX DATA+2
Rx B+
4 N/C
Tx
C+
5 N/C
Tx
C-
6
RX DATA-
Rx B-
7 N/C
Rx
D+
8 N/C
Rx
D-
Figure
3-12: RJ-45 LAN Ethernet Network Port and Connector
3.3.4
Connecting the Alarm Terminal Block Closures
The Alarm Terminal Block closure on the PEM module contains four groups of terminals for
connecting external Telco alarm devices according to Critical, Major, and Minor severity
levels. Devices can be controlled using the Common (COM) and Normally Open (NO)
method. The IN connector is for user-defined connections (currently not supported).
The PEM module provides three dry contact relays for connecting to Telco alarm
equipment. Each alarm output is a dry relay contact. Each contact can withstand up to a
maximum of 30 VDC when open and carries up to a maximum of 2 A DC when closed.
Содержание TP-6310
Страница 1: ...Document LTRT 94701 May 2008 Hardware Installation Manual Version 5 4...
Страница 2: ......
Страница 10: ...SIP Hardware Installation Manual 10 Document LTRT 94701 3000 Series Gateways Media Servers Reader s Notes...
Страница 42: ...SIP Hardware Installation Manual 42 Document LTRT 94701 3000 Series Gateways Media Servers Reader s Notes...
Страница 70: ...Hardware Installation Manual Version 5 4 www audiocodes com...