background image

7

Installation

In your system 

To ensure normal component life and safe 

operation this unit must be operated 

only in an upright position.  Adequate 

airflow and proper cooling can occur 

only if there is no restriction above and 

behind the unit and on either side. 

The special non-marring elastomer feet 

provide adequate spacing and stability 

only on a smooth, hard surface, and also 

assist to isolate the preamplifier from 

spurious vibrations. For upright stability 

and best performance, never operate 

the unit while it is sitting on a soft 

surface such as a thick rug or carpet.

Due to its weight, this preamplifier must 

be supported on a surface specifically 

rated for such a load.  Check with the 

manufacturer of your support system to 

be sure it is rated to handle this weight.

If the unit is to be operated in an enclosure 

such as an equipment rack, make certain 

that adequate airflow above and to 

each side of the unit is provided. Audio 

Research recommends a minimum of 

6-8 inches (15-20 cm) of clearance above 

the Reference 6 to maintain proper 

ambient operating temperature.

The ‘ambient’ operating temperature should 

never exceed 120° F or 49° C. Improper 

installation will cause premature tube 

failure and will affect your warranty, 

as well as the service life of the unit.

It is normal for a vacuum tube preamplifier 

to run quite warm, and if used for 

prolonged periods, hot to the touch. 

All components within are, however, 

operated at safe, conservative levels 

and will not be improperly affected 

thereby, providing the requirements 

outlined above are adhered to.

A Note about Vacuum Tubes

The vacuum tubes in your Reference 6 have 

been burned in, tested and electrically 

matched to provide the best performance 

and reliability of your preamplifier. That 

said, vacuum tubes must be replaced 

from time to time. The 6H30 tubes in 

the Reference 6 should have an expected 

life of approximately 4,000 hours, 

while the 6550WE tube in the power 

supply should have a life expectancy of 

approximately 2,000 hours. These life 

expectancies are only approximate. 

Содержание Reference 6

Страница 1: ...Reference 6 H I G H D E F I N I T I O N...

Страница 2: ......

Страница 3: ...eager to begin listening however please take a few minutes to read through this guide for useful information concerning the operation of your new preamplifier Once installed please allow an appropriat...

Страница 4: ...8 9 9 9 9 9 Operation Front Panel Controls and Display Start Up Shut Down Break in Front Panel Controls Remote Only Functions Settings Menu System Settings Menu Tree Settings Menu Auto Shutdown Proces...

Страница 5: ...e only with the same type and rating as specified at the fuse holder see page 19 for fuse information This unit is RoHS compliant The Reference 6 has automatic muting to help protect system components...

Страница 6: ...pply Proceed according to the following instructions Installation Remove all screws fastening the top cover Carefully remove each vacuum tube from its protective foam and match its location V number w...

Страница 7: ...provided Audio Research recommends a minimum of 6 8 inches 15 20 cm of clearance above the Reference 6 to maintain proper ambient operating temperature The ambient operating temperature should never...

Страница 8: ...8 Connections A C Mains connector Fuse Holder RS 232 connector Control connections Balanced Inputs Single ended Inputs Main Outputs Back Panel Connections Record Outputs...

Страница 9: ...could cause serious serious damage tot the amplifier s or loudspeakers A C Power Connection It is important that the Reference 6 be connected via its supplied 20 amp IEC 14 gauge power cord to a secu...

Страница 10: ...10 Operation Front Panel Controls and Display Input Select Vacuum Flourescent Display Volume Power On Off Menu Enter used with Menu Mono Stereo Invert Phase Mute...

Страница 11: ...ll flash on the display until the warm up cycle is complete Select input source and adjust the volume as necessary Shut Down Activate MUTE function Turn off power amplifier s Press Power switch to off...

Страница 12: ...indicated by active display window The Reference 6 requires approximately 45 seconds to warm up this time is required to stabilize the vacuum tubes See Start Up Procedure on page 11 for details Menu...

Страница 13: ...4 allow direct selection of each of the eight inputs available on the Reference 6 Display Brightness Adjustment The front panel display has six brightness settings as well as the ability to dim the d...

Страница 14: ...14 Operation System Settings Menu Tree...

Страница 15: ...of the front panel display Both the MENU and ENTER buttons found on the front panel and remote as well as the volume knob or the up down volume buttons on the remote are used to make changes to the m...

Страница 16: ...nput on the bottom line When using the input selected for processor mode note that in place of the volume number on the operation screen a pass through symbol will be shown Warning When processor mode...

Страница 17: ...t them to zero after a power off cycle When volume reset is set to OFF the Reference 6 will also remember settings after a power cycle To change the status of the volume reset press the MENU button un...

Страница 18: ...tamper with a component or part inside the unit Even with the power turned off a charge remains in the energy storage capacitors for some time Cleaning To maintain the new appearance of this preampli...

Страница 19: ...the function of the fuse will not only void the warranty in the event of damage but could also cause serious system failure fire or personal injury A C Mains Fuse 120 V units 5A slow blow 220 240 V un...

Страница 20: ...the United States the authorized importing retailer or distributor has accepted the responsibility for warranty of Audio Research products sold by them The specific terms and remedies for fulfillment...

Страница 21: ...oad maximum balanced output capability is 70V RMS at less than 0 5 THD at 1kHz Crosstalk 88dB or better at 1kHz and 10 kHz Controls Rotary encoders Volume 103 steps Select Input Push Buttons Power Men...

Страница 22: ...rch Corporation Reproduction of this document in part or whole is expressly forbidden without written consent from Audio Research Corporation H I G H D E F I N I T I O N 3900 Annapolis Lane North Plym...

Отзывы: