Processor Mode 

The Reference 6 has the ability to assign 

unity gain (also called ‘pass through’) to 

one of the eight inputs available in the 

event it will be integrated into a system 

with a secondary control device, such as a 

surround sound processor. When an input 

is assigned as the processor input, the 

volume control on the Reference 6  

is disabled so that the processor’s 

volume is the only control used.

To set up a processor input, connect the 

left and right output channels from 

your surround sound processor to the 

left and right inputs of your choice 

on the Reference 6. Press the ‘MENU’ 

button until ‘PROCESSOR MODE’ 

is displayed, and press ‘ENTER’.

With ‘PROCESSOR’ displayed, turn the 

volume knob, or use the up/down 

volume buttons on the remote, to select 

the desired input for processor mode. 

Press the ‘ENTER’ button to select 

the input, and ‘ENTER’ once again to 

confirm the selection. The Reference 

6 will display ‘OKAY’ and show the 

selected input on the bottom line. 

When using the input selected for processor 

mode, note that in place of the volume 

number on the operation screen, a 

‘pass through’ symbol will be shown.

 

Warning

When processor mode is assigned to an 

input, do 

NOT

 connect a source (such as 

a CD player or phono stage) to that input. 

This will send full output from the source 

to your amplifier(s), and could cause 

serious damage to your loudspeakers or 

amplifier(s) - not to mention your ears!

Operation

Tube Hours

The tube hours display shows the 

accumulated time the Reference 6 has been 

powered on. This is useful for determining 

the number of usage hours of the installed 

vacuum tubes. See 

A Note about Vacuum 

Tubes

 on page 7 for specific information 

regarding the tubes in the Reference 6. 

To reset the tube hours counter, press 

the ‘MENU’ button until ‘TUBE HOURS’ 

is shown. Press the ‘ENTER’ button to 

display ‘ENTER TO RESET’. Press ‘ENTER’ 

again and the display will read ‘ENTER TO 

CONFIRM’. A final press of the ‘ENTER’ 

button will reset the tube hour counter 

to 0 and the display will show ‘OKAY’.

Note

Once the hour counter has been 

reset, the total accumulated 

hours cannot be recalled.

Содержание Reference 6

Страница 1: ...Reference 6 H I G H D E F I N I T I O N...

Страница 2: ......

Страница 3: ...eager to begin listening however please take a few minutes to read through this guide for useful information concerning the operation of your new preamplifier Once installed please allow an appropriat...

Страница 4: ...8 9 9 9 9 9 Operation Front Panel Controls and Display Start Up Shut Down Break in Front Panel Controls Remote Only Functions Settings Menu System Settings Menu Tree Settings Menu Auto Shutdown Proces...

Страница 5: ...e only with the same type and rating as specified at the fuse holder see page 19 for fuse information This unit is RoHS compliant The Reference 6 has automatic muting to help protect system components...

Страница 6: ...pply Proceed according to the following instructions Installation Remove all screws fastening the top cover Carefully remove each vacuum tube from its protective foam and match its location V number w...

Страница 7: ...provided Audio Research recommends a minimum of 6 8 inches 15 20 cm of clearance above the Reference 6 to maintain proper ambient operating temperature The ambient operating temperature should never...

Страница 8: ...8 Connections A C Mains connector Fuse Holder RS 232 connector Control connections Balanced Inputs Single ended Inputs Main Outputs Back Panel Connections Record Outputs...

Страница 9: ...could cause serious serious damage tot the amplifier s or loudspeakers A C Power Connection It is important that the Reference 6 be connected via its supplied 20 amp IEC 14 gauge power cord to a secu...

Страница 10: ...10 Operation Front Panel Controls and Display Input Select Vacuum Flourescent Display Volume Power On Off Menu Enter used with Menu Mono Stereo Invert Phase Mute...

Страница 11: ...ll flash on the display until the warm up cycle is complete Select input source and adjust the volume as necessary Shut Down Activate MUTE function Turn off power amplifier s Press Power switch to off...

Страница 12: ...indicated by active display window The Reference 6 requires approximately 45 seconds to warm up this time is required to stabilize the vacuum tubes See Start Up Procedure on page 11 for details Menu...

Страница 13: ...4 allow direct selection of each of the eight inputs available on the Reference 6 Display Brightness Adjustment The front panel display has six brightness settings as well as the ability to dim the d...

Страница 14: ...14 Operation System Settings Menu Tree...

Страница 15: ...of the front panel display Both the MENU and ENTER buttons found on the front panel and remote as well as the volume knob or the up down volume buttons on the remote are used to make changes to the m...

Страница 16: ...nput on the bottom line When using the input selected for processor mode note that in place of the volume number on the operation screen a pass through symbol will be shown Warning When processor mode...

Страница 17: ...t them to zero after a power off cycle When volume reset is set to OFF the Reference 6 will also remember settings after a power cycle To change the status of the volume reset press the MENU button un...

Страница 18: ...tamper with a component or part inside the unit Even with the power turned off a charge remains in the energy storage capacitors for some time Cleaning To maintain the new appearance of this preampli...

Страница 19: ...the function of the fuse will not only void the warranty in the event of damage but could also cause serious system failure fire or personal injury A C Mains Fuse 120 V units 5A slow blow 220 240 V un...

Страница 20: ...the United States the authorized importing retailer or distributor has accepted the responsibility for warranty of Audio Research products sold by them The specific terms and remedies for fulfillment...

Страница 21: ...oad maximum balanced output capability is 70V RMS at less than 0 5 THD at 1kHz Crosstalk 88dB or better at 1kHz and 10 kHz Controls Rotary encoders Volume 103 steps Select Input Push Buttons Power Men...

Страница 22: ...rch Corporation Reproduction of this document in part or whole is expressly forbidden without written consent from Audio Research Corporation H I G H D E F I N I T I O N 3900 Annapolis Lane North Plym...

Отзывы: