background image

13

Operation

Remote Only Functions

In addition to the controls found on the 

front panel, the remote control offers 

access to the following additional 

features of the Reference 6.

Hours

Pressing the ‘HOURS’ button will display 

the total accumulated hours of operation 

for the Reference 6. This is useful to 

determine the approximate number of 

hours the vacuum tubes have been in 

use. After five seconds, the display will 

revert to the normal operation screen. 

After replacing vacuum tubes, the hours 

counter should be reset (see instructions 

under ‘Settings Menu’ on page 16).

Note

The installed 6H30 vacuum tubes have 

an average life span of approximately 

4,000 hours, and the 6550WE has an 

average life span of approximately 2,000 

hours. After this time, we recommend 

replacing them to maintain the best 

performance of your preamplifier.

Input Select Buttons

The input buttons labeled BAL 1-4 and SE 

1-4 allow direct selection of each of the 

eight inputs available on the Reference 6.

Display Brightness Adjustment

The front panel display has six brightness 

settings, as well as the ability to dim 

the display completely. To change the 

brightness, use the ‘DSP UP’ or ‘DSP DN’ 

buttons on the remote. Note that when 

the display is completely dimmed, a 

small square appears in the middle of the 

display to indicate the unit is powered on. 

Balance

The Balance control adjusts the output from 

center position to the left or right channels, 

which in turn will shift the center point of 

the sonic image. This is useful in the event 

the main listening position is not centered 

between the speakers, or can help with 

certain room anomalies.

To adjust the balance, press the ‘BAL L’ or 

‘BAL R’ button on the remote. The balance 

scale will appear in the middle of the 

display, and the indicator block will move in 

the selected direction:

After five seconds of inactivity, the 

balance scale will disappear from the 

screen. If the balance has been shifted 

to the right or left, ‘R+’ or ‘L+’ will 

appear at the bottom left corner.

Содержание Reference 6

Страница 1: ...Reference 6 H I G H D E F I N I T I O N...

Страница 2: ......

Страница 3: ...eager to begin listening however please take a few minutes to read through this guide for useful information concerning the operation of your new preamplifier Once installed please allow an appropriat...

Страница 4: ...8 9 9 9 9 9 Operation Front Panel Controls and Display Start Up Shut Down Break in Front Panel Controls Remote Only Functions Settings Menu System Settings Menu Tree Settings Menu Auto Shutdown Proces...

Страница 5: ...e only with the same type and rating as specified at the fuse holder see page 19 for fuse information This unit is RoHS compliant The Reference 6 has automatic muting to help protect system components...

Страница 6: ...pply Proceed according to the following instructions Installation Remove all screws fastening the top cover Carefully remove each vacuum tube from its protective foam and match its location V number w...

Страница 7: ...provided Audio Research recommends a minimum of 6 8 inches 15 20 cm of clearance above the Reference 6 to maintain proper ambient operating temperature The ambient operating temperature should never...

Страница 8: ...8 Connections A C Mains connector Fuse Holder RS 232 connector Control connections Balanced Inputs Single ended Inputs Main Outputs Back Panel Connections Record Outputs...

Страница 9: ...could cause serious serious damage tot the amplifier s or loudspeakers A C Power Connection It is important that the Reference 6 be connected via its supplied 20 amp IEC 14 gauge power cord to a secu...

Страница 10: ...10 Operation Front Panel Controls and Display Input Select Vacuum Flourescent Display Volume Power On Off Menu Enter used with Menu Mono Stereo Invert Phase Mute...

Страница 11: ...ll flash on the display until the warm up cycle is complete Select input source and adjust the volume as necessary Shut Down Activate MUTE function Turn off power amplifier s Press Power switch to off...

Страница 12: ...indicated by active display window The Reference 6 requires approximately 45 seconds to warm up this time is required to stabilize the vacuum tubes See Start Up Procedure on page 11 for details Menu...

Страница 13: ...4 allow direct selection of each of the eight inputs available on the Reference 6 Display Brightness Adjustment The front panel display has six brightness settings as well as the ability to dim the d...

Страница 14: ...14 Operation System Settings Menu Tree...

Страница 15: ...of the front panel display Both the MENU and ENTER buttons found on the front panel and remote as well as the volume knob or the up down volume buttons on the remote are used to make changes to the m...

Страница 16: ...nput on the bottom line When using the input selected for processor mode note that in place of the volume number on the operation screen a pass through symbol will be shown Warning When processor mode...

Страница 17: ...t them to zero after a power off cycle When volume reset is set to OFF the Reference 6 will also remember settings after a power cycle To change the status of the volume reset press the MENU button un...

Страница 18: ...tamper with a component or part inside the unit Even with the power turned off a charge remains in the energy storage capacitors for some time Cleaning To maintain the new appearance of this preampli...

Страница 19: ...the function of the fuse will not only void the warranty in the event of damage but could also cause serious system failure fire or personal injury A C Mains Fuse 120 V units 5A slow blow 220 240 V un...

Страница 20: ...the United States the authorized importing retailer or distributor has accepted the responsibility for warranty of Audio Research products sold by them The specific terms and remedies for fulfillment...

Страница 21: ...oad maximum balanced output capability is 70V RMS at less than 0 5 THD at 1kHz Crosstalk 88dB or better at 1kHz and 10 kHz Controls Rotary encoders Volume 103 steps Select Input Push Buttons Power Men...

Страница 22: ...rch Corporation Reproduction of this document in part or whole is expressly forbidden without written consent from Audio Research Corporation H I G H D E F I N I T I O N 3900 Annapolis Lane North Plym...

Отзывы: