Some factors relating to output performance are:

1.  City or Park Water Service incoming pressures.
2.  Obstructions or restrictions in the water system including  
 

water bypass valves in vehicles. The bypass valve in your  

 

water system should be OFF during normal use.

3.  Use of flow restrictors in faucets and/or shower heads.    
 

Eliminate restrictors for best performance.

4.  Propane gas system pressure should be 11”w.c. while in  
 

operation. Be sure that LP tanks have plenty of gas and   

 

are properly regulated. This should be verified by an  

 

 

authorized Atwood service technician.

If problems persist, please contact the nearest authorized
Atwood Service Center or call Atwood Technical Support at
1-866-869-3118.

MAX

MIN

FACTORY
SETTING

modulating valve as viewed from exterior door

m

 

caution

scalDinG inJury

Setting temperature control dial 

at a higher position increases 

temperature of the water, 

increasing the risk of scalding 

injury. Before selecting or 

changing the temperature setting, 

see instruction manual 

MPD 93756.

ProDucT DamaGe

BURNER TUBE – Spiders or insects 

can build nests in burner tube causing 

obstructions. Indications of obstructions 

are: • change in burner sound • change in 

flame appearance from a hard blue flame 

to a soft lazy flame • very yellow flame • 

sooting condition. Regularly inspect and 

clean burner tube to prevent obstructions.

cauTion:

 Consult 

Owner’s Manual 
before adjusting the 
Modulating Valve

summer operation:

During the summer months when the incoming water 
temperatures are relatively warm (ranging from 70°F to 90°F) 
it is recommended that the modulating valve adjustment be 
placed in the MIN position. This reduces the gas input of the 
heater to keep the water temperature from getting too hot 
with high incoming water temperature

Winter operation:

During the winter months when incoming water temperatures 
are cooler (ranging from 45°F to 70°F) it is recommended to 
place the modulating valve adjustment in the MAX position.
In addition, the OD50 comes equipped with a cold weather 
switch on the heat exchanger that will cycle the burners 
on and off at low input when the temperature of the heat 
exchanger reaches approximately 38°F and leaves the 
burners on until the temperature of the switch reaches 
approximately 55°F. This protection is only recommended for 
camping in weather down to 15°F.
For operation during even colder outside temperatures (as 
low as -15°F) the cold weather kit option (or model OD50CW) 
is recommended. The cold weather kit consists of a 12 VDC 
heat pad for the modulating valve and 2 ceramic heat blocks 
for the water lines. This will keep the water in the system from 
freezing when in the OFF state in extreme cold conditions.

Without the cold Weather Kit installed

With the cold Weather Kit installed

Winter Protection During storage:

Before storing the system for the winter, all water should
be drained from the system. To do this, open one tap at
a time using compressed air to purge the system of all water.
Then either of the following steps should be taken:
1)  Once purged, simply open the Pressure Relief Valve and  
 

leave in the open position.

2)  Once purged, close the Pressure Relief valve and add a   
 

non-toxic RV antifreeze if recommended by your coach   

 manufacturer.

Содержание OD50

Страница 1: ...s Btu 01__________ Generation CW______ Cold Weather Kit m critical installation warnings Install in recreation vehicles only RV s are recreation vehicles designed as temporary living quarters for recreation camping or travel use having their own power or towed by another vehicle All combustion air must be supplied from outside the RV and all products of combustion must be vented to outside the RV ...

Страница 2: ...rmined and is being installed at the OEM prior to erecting the walls NOTE Parts bagged and included with the unit in the box are the corner filler brackets and push on water line connectors 1 Locate the water heater on the floor of the coach at pre determined location The unit must be permanently supported at the same level as the bottom of the sidewall cutout by the floor or a raised floor 2 To i...

Страница 3: ...periodic inspection of product of listed equipment or materials as meeting requirements for Relief Valves and Automatic Gas Shutoff Devices of Hot Water Supply Systems ANSI Z21 22 CSA 4 4 Valve must have maximum set pressure not to exceed 100 psi Install replacement valve into opening provided and designated for this purpose on water heater Installation must conform with local codes or in the abse...

Страница 4: ... COLD PACK OPTIONAL IGN CONT SPARK SENSE WIRING SCHEMATIC GREEN GREEN RED RED PURPLE BROWN BROWN RED RED RED PURPLE RED RED BLUE BLUE LOCKOUT LAMP OPTIONAL MPD 90211 m CAUTION FIRE DO NOT smoke or have any flame near an open faucet GENERAL INFORMATION LP and Water system must be turned on Have gas pressure tested periodically Should be set at 11 inches of water column with three appliances running...

Страница 5: ...warm ranging from 70 F to 90 F it is recommended that the modulating valve adjustment be placed in the MIN position This reduces the gas input of the heater to keep the water temperature from getting too hot with high incoming water temperature Winter Operation During the winter months when incoming water temperatures are cooler ranging from 45 F to 70 F it is recommended to place the modulating v...

Страница 6: ...ulting the trouble shooting guide If problems still persist contact Atwood or an authorized service center Only a qualified technician should do any work involving the gas system A periodic visual check of the burner flames should be done by observing the flame through the peep hole in the heat exchanger There should be blue flame with minimum or no yellow tipping Burner maintenance should be perf...

Страница 7: ...inter summer valve is in the proper position for the temperature of the incoming water 3 Water flow too low for incoming water temperature 5 Be sure there is a battery in the system Never connect the heater directly to a power converter Some converters have circuits that are not pure DC This can cause malfunctions or damage to the heater and is not covered by warranty 6 Be sure that no water mixin...

Страница 8: ...lacement of burner orifices c cleaning or adjustment of burner assembly d cleaning or adjustment of flue e adjustment of pressure relief valve 4 In the event of a warranty claim the owner must contact in advance either an authorized Atwood Service Center or the Atwood Service Department Warranty claim service must be performed at an authorized Atwood Service Center can be found online www atwoodmo...

Страница 9: ... ont pas été réparées L installation et la réparation doivent être effectuées par un installateur qualifié une agence de service ou le fournisseur de gaz Explication du numéro du modèle OD_____________________ À la demande On demand 50________________ Entrée en milliers de BTU 01__________ Génération CW______ Kit de temps froid m AVERTISSEMENTS CRITIQUEs SUR L INSTALLATION À installer dans les véh...

Страница 10: ... y a d autres méthodes approuvées comme celles dans le coffre à bagages ou le boîtier encastré Pour toute question supplémentaire veuillez consulter votre vérificateur sur place votre directeur de compte ou le service à la clientèle Atwood Avant de commencer assurez vous que l emplacement approprié a été déterminé et installé par le FEO avant l érection des murs REMARQUE Les pièces mises en sac et...

Страница 11: ...e l interrupteur en position OFF ROUGE est le courant positif d entrée de 12 V c c VERT est la mise à la terre de 12 V c c BLEU est le signal de verrouillage de 12 V c c positif Voir l illustration de la configuration de commutation type 7 Pour prévenir les fuites d eau calfeutrez soigneusement le pourtour arrière des brides et sur les fentes pliées et perforées Calfeutrez le pourtour de l ouvertu...

Страница 12: ... ouvrez le robinet d eau chaude de l évier de cuisine pendant plusieurs minutes avant d utiliser tout appareil électrique relié au système d eau chaude Si de l hydrogène gazeux est présent vous allez probablement entendre des sons tels que l air qui s échappe par le tuyau au moment où l eau commence à couler 1 Mettre en pression le système d eau en tournant sur la pompe ou la pression d eau de vil...

Страница 13: ...débit dans les robinets et ou des pommes de douche Éliminer les restricteurs pour de meilleures performances 4 Propane pression du système de gaz doit être 11 W C en cours de fonctionnement Assurez vous que les réservoirs de propane comportent beaucoup de gaz et sont correctement régulés Cela doit être vérifié par un technicien agréé Atwood Si le problème persiste s il vous plaît contacter le cent...

Страница 14: ... 90290 LISTE DES PIÈCES DU CHAUFFE EAU DÉPANNAGE La plupart des problèmes sont facilement résolus en consultant le guide de dépannage Si le problème persiste veuillez contacter Atwood ou un centre de service agréé Seul un technicien qualifié devrait effectuer tout travail impliquant le système de gaz Une vérification périodique visuelle des flammes du brûleur devrait être faite en observant la fla...

Страница 15: ...avec le terminal seulement 5 Assurez vous que l alimentation du ventilateur a 12 volts lorsque de l eau coule et qu il n y a pas d obstacles dans le conduit d air 6 Assurez vous que mano contact est clôturé par la vérification la tension à travers des terminaux devrait être de 0 volts si lisant 12 volts vérifient l obstruction de conduite ou l obstruction dans la ligne de sens tuyauterie L eau ne ...

Страница 16: ...rais d essence de téléphone de déplacement d hébergement le manque à gagner ou les dommages matériels Certains États n autorisent pas les exclusions ou les restrictions des dommages accessoires ou consécutifs par conséquent il est possible que les restrictions ou les exclusions précédentes ne s appliquent pas à vous 10 Les garanties implicites se limitent à une période de deux 2 ans Certains États...

Отзывы: