HOW TO OPerATe yOUr WATer HeATer

If water heater has not been used for more than two weeks, 
hydrogen gas may form in water line. Under these conditions 
to reduce the risk of injury, open hot water faucet for several 
minutes at kitchen sink before you use any electrical appliance 
connected to hot water system.
If hydrogen gas is present, you will probably hear sounds like air 
escaping through the pipe as water begins to flow.

1)  Pressurize the water system by turning on pump or city   
 

water pressure.

2)  Purge all air from the system by turning on the faucets    
 

until a steady stream of water flows.

3)  Turn on the 12V DC power supply.
4)  Turn on the LP supply at the tank and the manual gas    
 

valve (if installed). The water heater will remain dormant   

 

until a water tap is opened and the heater senses water   

 

flow of at least 0.5 GPM.

5)  Turn on the hot water tap to full open. The heater will fire  
 

up within several seconds and hot water will flow from the  

 

tap in the time it takes to traverse the lines from the heater  

 

to the faucet. (If this is the first usage, you may have to   

 

turn the water on and off several times to purge the LP    

 

gas lines of air.) If the heater fails to light or the lockout   

 

lamp (optional) illuminates, turn the power switch OFF,    

 

then On to reset the ignition control.

6)  To shut off the water heater, shut off the water.
7)  Should overheating occur or the gas supply fail to shut off,  
 

turn off the “On/OF” power switch.

a note about “navy showers” When Dry camping

It is recommended to take a shower just like you would at 
home. That is, leave the water running through the entire 
shower. The hot water system is designed to deliver a 
continuous, comfortable flow of hot water and that’s the way it 
works best.
Shutting off the shower with the showerhead button wastes 
water. Each time this is done, the showerhead “trickles”, filling 
the hot water line with cold water. This cold water has to be 
purged from the line each time the showerhead is turned back 
on. Tests have shown that this will not save water.

GAS VALVE

PRESSURE SWITCH

RELAY

FUSE

ECO

FREEZE

PROX

+ 12V DC

GROUND

COLD PACK

(OPTIONAL)

IGN. CONT

SPARK & SENSE

WIRING

SCHEMATIC

(GREEN)

(GREEN)

(RED)

(RED)

(PURPLE)

(BROWN)

(BROWN)

(RED)

(RED)

(RED)

(PURPLE)

(RED)

(RED)

(BLUE)

(BLUE)

LOCKOUT

LAMP

(OPTIONAL)

MPD 90211

m

 

caution

 FirE

•  DO NOT smoke or have any flame near an open faucet.

General informaTion

•  LP and Water system must be turned on.
•  Have gas pressure tested periodically. Should be set at 11  
  inches of water column with three appliances running.
•  Drain water heater at regular intervals (at least one time    
  during the year).
•  Drain water heater before storing RV for the winter or when  
  the possibility of freezing exists.
•  Keep vent and combustion air grill clear of any    

 

 obstructions.

elecTronic iGniTion mainTenance

•  The water heater comes factory-equipped with an in line   
  fuse, which will protect the circuit board from wiring shorts.  
  If the fuse should blow, the water heater will not operate.   
  Before replacing the fuse, check for a short external to the  
  board. Once the short is corrected, replace the 3 amp fuse.  
  Do not install a fuse larger than 3 amps.
•  If the fuse is good and the unit is inoperative, check for    
  excessively high voltage to the unit (more than 14 volts).

moDulaTinG valve aDJusTmenT:

The modulating water valve will have a factory preset setting 
which is designed and tested for an approximate 65°F rise in 
temperature for a hot water flow rate ranging from 1.00 GPM 
to 1.25 GPM as measured at the water outlet (ie. faucet or 
shower head). Pictures of this valve adjustment are on the 
next page. The consumer is encouraged to set the modulating 
valve to provide hot water in the 110°F-115°F range. The 
consumer can then add cold water to achieve the desired 
hot water temperature. Care must be taken to prevent higher 
temperatures which may result in scalding. 
The factory setting will satisfy most applications, however the 
modulating water valve has been designed with flexibility in 
mind to handle a wide range of diverse situations. For hotter 
water temperatures the modulating valve can be adjusted 
counter-clockwise toward the MAX position; for cooler hot 
water temperatures, the modulating valve can be adjusted 
clockwise toward the MIN position. One should use caution 
not to force the valve adjustment beyond the MAX and MIN 
points. 

m

 

caution

•  Consult Owner’s Manual before adjusting the Modulating    
 Valve.

Содержание OD50

Страница 1: ...s Btu 01__________ Generation CW______ Cold Weather Kit m critical installation warnings Install in recreation vehicles only RV s are recreation vehicles designed as temporary living quarters for recreation camping or travel use having their own power or towed by another vehicle All combustion air must be supplied from outside the RV and all products of combustion must be vented to outside the RV ...

Страница 2: ...rmined and is being installed at the OEM prior to erecting the walls NOTE Parts bagged and included with the unit in the box are the corner filler brackets and push on water line connectors 1 Locate the water heater on the floor of the coach at pre determined location The unit must be permanently supported at the same level as the bottom of the sidewall cutout by the floor or a raised floor 2 To i...

Страница 3: ...periodic inspection of product of listed equipment or materials as meeting requirements for Relief Valves and Automatic Gas Shutoff Devices of Hot Water Supply Systems ANSI Z21 22 CSA 4 4 Valve must have maximum set pressure not to exceed 100 psi Install replacement valve into opening provided and designated for this purpose on water heater Installation must conform with local codes or in the abse...

Страница 4: ... COLD PACK OPTIONAL IGN CONT SPARK SENSE WIRING SCHEMATIC GREEN GREEN RED RED PURPLE BROWN BROWN RED RED RED PURPLE RED RED BLUE BLUE LOCKOUT LAMP OPTIONAL MPD 90211 m CAUTION FIRE DO NOT smoke or have any flame near an open faucet GENERAL INFORMATION LP and Water system must be turned on Have gas pressure tested periodically Should be set at 11 inches of water column with three appliances running...

Страница 5: ...warm ranging from 70 F to 90 F it is recommended that the modulating valve adjustment be placed in the MIN position This reduces the gas input of the heater to keep the water temperature from getting too hot with high incoming water temperature Winter Operation During the winter months when incoming water temperatures are cooler ranging from 45 F to 70 F it is recommended to place the modulating v...

Страница 6: ...ulting the trouble shooting guide If problems still persist contact Atwood or an authorized service center Only a qualified technician should do any work involving the gas system A periodic visual check of the burner flames should be done by observing the flame through the peep hole in the heat exchanger There should be blue flame with minimum or no yellow tipping Burner maintenance should be perf...

Страница 7: ...inter summer valve is in the proper position for the temperature of the incoming water 3 Water flow too low for incoming water temperature 5 Be sure there is a battery in the system Never connect the heater directly to a power converter Some converters have circuits that are not pure DC This can cause malfunctions or damage to the heater and is not covered by warranty 6 Be sure that no water mixin...

Страница 8: ...lacement of burner orifices c cleaning or adjustment of burner assembly d cleaning or adjustment of flue e adjustment of pressure relief valve 4 In the event of a warranty claim the owner must contact in advance either an authorized Atwood Service Center or the Atwood Service Department Warranty claim service must be performed at an authorized Atwood Service Center can be found online www atwoodmo...

Страница 9: ... ont pas été réparées L installation et la réparation doivent être effectuées par un installateur qualifié une agence de service ou le fournisseur de gaz Explication du numéro du modèle OD_____________________ À la demande On demand 50________________ Entrée en milliers de BTU 01__________ Génération CW______ Kit de temps froid m AVERTISSEMENTS CRITIQUEs SUR L INSTALLATION À installer dans les véh...

Страница 10: ... y a d autres méthodes approuvées comme celles dans le coffre à bagages ou le boîtier encastré Pour toute question supplémentaire veuillez consulter votre vérificateur sur place votre directeur de compte ou le service à la clientèle Atwood Avant de commencer assurez vous que l emplacement approprié a été déterminé et installé par le FEO avant l érection des murs REMARQUE Les pièces mises en sac et...

Страница 11: ...e l interrupteur en position OFF ROUGE est le courant positif d entrée de 12 V c c VERT est la mise à la terre de 12 V c c BLEU est le signal de verrouillage de 12 V c c positif Voir l illustration de la configuration de commutation type 7 Pour prévenir les fuites d eau calfeutrez soigneusement le pourtour arrière des brides et sur les fentes pliées et perforées Calfeutrez le pourtour de l ouvertu...

Страница 12: ... ouvrez le robinet d eau chaude de l évier de cuisine pendant plusieurs minutes avant d utiliser tout appareil électrique relié au système d eau chaude Si de l hydrogène gazeux est présent vous allez probablement entendre des sons tels que l air qui s échappe par le tuyau au moment où l eau commence à couler 1 Mettre en pression le système d eau en tournant sur la pompe ou la pression d eau de vil...

Страница 13: ...débit dans les robinets et ou des pommes de douche Éliminer les restricteurs pour de meilleures performances 4 Propane pression du système de gaz doit être 11 W C en cours de fonctionnement Assurez vous que les réservoirs de propane comportent beaucoup de gaz et sont correctement régulés Cela doit être vérifié par un technicien agréé Atwood Si le problème persiste s il vous plaît contacter le cent...

Страница 14: ... 90290 LISTE DES PIÈCES DU CHAUFFE EAU DÉPANNAGE La plupart des problèmes sont facilement résolus en consultant le guide de dépannage Si le problème persiste veuillez contacter Atwood ou un centre de service agréé Seul un technicien qualifié devrait effectuer tout travail impliquant le système de gaz Une vérification périodique visuelle des flammes du brûleur devrait être faite en observant la fla...

Страница 15: ...avec le terminal seulement 5 Assurez vous que l alimentation du ventilateur a 12 volts lorsque de l eau coule et qu il n y a pas d obstacles dans le conduit d air 6 Assurez vous que mano contact est clôturé par la vérification la tension à travers des terminaux devrait être de 0 volts si lisant 12 volts vérifient l obstruction de conduite ou l obstruction dans la ligne de sens tuyauterie L eau ne ...

Страница 16: ...rais d essence de téléphone de déplacement d hébergement le manque à gagner ou les dommages matériels Certains États n autorisent pas les exclusions ou les restrictions des dommages accessoires ou consécutifs par conséquent il est possible que les restrictions ou les exclusions précédentes ne s appliquent pas à vous 10 Les garanties implicites se limitent à une période de deux 2 ans Certains États...

Отзывы: